Cargando…

Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer

By far the largest contribution to ion detectability in liquid chromatography-driven mass spectrometry-based proteomics is the efficient generation of peptide ions by the electrospray source. To maximize the transfer of peptides from liquid to a gaseous phase to allow molecular ions to enter the mas...

Descripción completa

Detalles Bibliográficos
Autores principales: Midha, Mukul K., Kapil, Charu, Maes, Michal, Baxter, David H., Morrone, Seamus R., Prokop, Timothy J., Moritz, Robert L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cold Spring Harbor Laboratory 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9949110/
https://www.ncbi.nlm.nih.gov/pubmed/36824828
http://dx.doi.org/10.1101/2023.02.15.528699
_version_ 1784892908559663104
author Midha, Mukul K.
Kapil, Charu
Maes, Michal
Baxter, David H.
Morrone, Seamus R.
Prokop, Timothy J.
Moritz, Robert L.
author_facet Midha, Mukul K.
Kapil, Charu
Maes, Michal
Baxter, David H.
Morrone, Seamus R.
Prokop, Timothy J.
Moritz, Robert L.
author_sort Midha, Mukul K.
collection PubMed
description By far the largest contribution to ion detectability in liquid chromatography-driven mass spectrometry-based proteomics is the efficient generation of peptide ions by the electrospray source. To maximize the transfer of peptides from liquid to a gaseous phase to allow molecular ions to enter the mass spectrometer at micro-spray flow rates, an efficient electrospray process is required. Here we describe superior performance of new Vacuum-Insulated-Probe-Heated-ElectroSpray-Ionization source (VIP-HESI) coupled with micro-spray flow rate chromatography and Bruker timsTOF PRO mass spectrometer. VIP-HESI significantly improves chromatography signals in comparison to nano-spray ionization using the CaptiveSpray source and provides increased protein detection with higher quantitative precision, enhancing reproducibility of sample injection amounts. Protein quantitation of human K562 lymphoblast samples displayed excellent chromatographic retention time reproducibility (<10% coefficient-of-variation (CV)) with no signal degradation over extended periods of time, and a mouse plasma proteome analysis identified 12% more plasma protein groups allowing large-scale analysis to proceed with confidence (1,267 proteins at 0.4% CV). We show that Slice-PASEF mode with VIP-HESI setup is sensitive in identifying low amounts of peptide without losing quantitative precision. We demonstrate that VIP-HESI coupled with micro-flow-rate chromatography achieves higher depth of coverage and run-to-run reproducibility for a broad range of proteomic applications.
format Online
Article
Text
id pubmed-9949110
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cold Spring Harbor Laboratory
record_format MEDLINE/PubMed
spelling pubmed-99491102023-02-24 Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer Midha, Mukul K. Kapil, Charu Maes, Michal Baxter, David H. Morrone, Seamus R. Prokop, Timothy J. Moritz, Robert L. bioRxiv Article By far the largest contribution to ion detectability in liquid chromatography-driven mass spectrometry-based proteomics is the efficient generation of peptide ions by the electrospray source. To maximize the transfer of peptides from liquid to a gaseous phase to allow molecular ions to enter the mass spectrometer at micro-spray flow rates, an efficient electrospray process is required. Here we describe superior performance of new Vacuum-Insulated-Probe-Heated-ElectroSpray-Ionization source (VIP-HESI) coupled with micro-spray flow rate chromatography and Bruker timsTOF PRO mass spectrometer. VIP-HESI significantly improves chromatography signals in comparison to nano-spray ionization using the CaptiveSpray source and provides increased protein detection with higher quantitative precision, enhancing reproducibility of sample injection amounts. Protein quantitation of human K562 lymphoblast samples displayed excellent chromatographic retention time reproducibility (<10% coefficient-of-variation (CV)) with no signal degradation over extended periods of time, and a mouse plasma proteome analysis identified 12% more plasma protein groups allowing large-scale analysis to proceed with confidence (1,267 proteins at 0.4% CV). We show that Slice-PASEF mode with VIP-HESI setup is sensitive in identifying low amounts of peptide without losing quantitative precision. We demonstrate that VIP-HESI coupled with micro-flow-rate chromatography achieves higher depth of coverage and run-to-run reproducibility for a broad range of proteomic applications. Cold Spring Harbor Laboratory 2023-02-17 /pmc/articles/PMC9949110/ /pubmed/36824828 http://dx.doi.org/10.1101/2023.02.15.528699 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which allows reusers to copy and distribute the material in any medium or format in unadapted form only, for noncommercial purposes only, and only so long as attribution is given to the creator.
spellingShingle Article
Midha, Mukul K.
Kapil, Charu
Maes, Michal
Baxter, David H.
Morrone, Seamus R.
Prokop, Timothy J.
Moritz, Robert L.
Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer
title Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer
title_full Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer
title_fullStr Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer
title_full_unstemmed Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer
title_short Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer
title_sort vacuum insulated probe heated electrospray ionization source (vip-hesi) enhances micro flow rate chromatography signals in the bruker timstof mass spectrometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9949110/
https://www.ncbi.nlm.nih.gov/pubmed/36824828
http://dx.doi.org/10.1101/2023.02.15.528699
work_keys_str_mv AT midhamukulk vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer
AT kapilcharu vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer
AT maesmichal vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer
AT baxterdavidh vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer
AT morroneseamusr vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer
AT prokoptimothyj vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer
AT moritzrobertl vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer