Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer
By far the largest contribution to ion detectability in liquid chromatography-driven mass spectrometry-based proteomics is the efficient generation of peptide ions by the electrospray source. To maximize the transfer of peptides from liquid to a gaseous phase to allow molecular ions to enter the mas...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cold Spring Harbor Laboratory
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9949110/ https://www.ncbi.nlm.nih.gov/pubmed/36824828 http://dx.doi.org/10.1101/2023.02.15.528699 |
_version_ | 1784892908559663104 |
---|---|
author | Midha, Mukul K. Kapil, Charu Maes, Michal Baxter, David H. Morrone, Seamus R. Prokop, Timothy J. Moritz, Robert L. |
author_facet | Midha, Mukul K. Kapil, Charu Maes, Michal Baxter, David H. Morrone, Seamus R. Prokop, Timothy J. Moritz, Robert L. |
author_sort | Midha, Mukul K. |
collection | PubMed |
description | By far the largest contribution to ion detectability in liquid chromatography-driven mass spectrometry-based proteomics is the efficient generation of peptide ions by the electrospray source. To maximize the transfer of peptides from liquid to a gaseous phase to allow molecular ions to enter the mass spectrometer at micro-spray flow rates, an efficient electrospray process is required. Here we describe superior performance of new Vacuum-Insulated-Probe-Heated-ElectroSpray-Ionization source (VIP-HESI) coupled with micro-spray flow rate chromatography and Bruker timsTOF PRO mass spectrometer. VIP-HESI significantly improves chromatography signals in comparison to nano-spray ionization using the CaptiveSpray source and provides increased protein detection with higher quantitative precision, enhancing reproducibility of sample injection amounts. Protein quantitation of human K562 lymphoblast samples displayed excellent chromatographic retention time reproducibility (<10% coefficient-of-variation (CV)) with no signal degradation over extended periods of time, and a mouse plasma proteome analysis identified 12% more plasma protein groups allowing large-scale analysis to proceed with confidence (1,267 proteins at 0.4% CV). We show that Slice-PASEF mode with VIP-HESI setup is sensitive in identifying low amounts of peptide without losing quantitative precision. We demonstrate that VIP-HESI coupled with micro-flow-rate chromatography achieves higher depth of coverage and run-to-run reproducibility for a broad range of proteomic applications. |
format | Online Article Text |
id | pubmed-9949110 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cold Spring Harbor Laboratory |
record_format | MEDLINE/PubMed |
spelling | pubmed-99491102023-02-24 Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer Midha, Mukul K. Kapil, Charu Maes, Michal Baxter, David H. Morrone, Seamus R. Prokop, Timothy J. Moritz, Robert L. bioRxiv Article By far the largest contribution to ion detectability in liquid chromatography-driven mass spectrometry-based proteomics is the efficient generation of peptide ions by the electrospray source. To maximize the transfer of peptides from liquid to a gaseous phase to allow molecular ions to enter the mass spectrometer at micro-spray flow rates, an efficient electrospray process is required. Here we describe superior performance of new Vacuum-Insulated-Probe-Heated-ElectroSpray-Ionization source (VIP-HESI) coupled with micro-spray flow rate chromatography and Bruker timsTOF PRO mass spectrometer. VIP-HESI significantly improves chromatography signals in comparison to nano-spray ionization using the CaptiveSpray source and provides increased protein detection with higher quantitative precision, enhancing reproducibility of sample injection amounts. Protein quantitation of human K562 lymphoblast samples displayed excellent chromatographic retention time reproducibility (<10% coefficient-of-variation (CV)) with no signal degradation over extended periods of time, and a mouse plasma proteome analysis identified 12% more plasma protein groups allowing large-scale analysis to proceed with confidence (1,267 proteins at 0.4% CV). We show that Slice-PASEF mode with VIP-HESI setup is sensitive in identifying low amounts of peptide without losing quantitative precision. We demonstrate that VIP-HESI coupled with micro-flow-rate chromatography achieves higher depth of coverage and run-to-run reproducibility for a broad range of proteomic applications. Cold Spring Harbor Laboratory 2023-02-17 /pmc/articles/PMC9949110/ /pubmed/36824828 http://dx.doi.org/10.1101/2023.02.15.528699 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which allows reusers to copy and distribute the material in any medium or format in unadapted form only, for noncommercial purposes only, and only so long as attribution is given to the creator. |
spellingShingle | Article Midha, Mukul K. Kapil, Charu Maes, Michal Baxter, David H. Morrone, Seamus R. Prokop, Timothy J. Moritz, Robert L. Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer |
title | Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer |
title_full | Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer |
title_fullStr | Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer |
title_full_unstemmed | Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer |
title_short | Vacuum Insulated Probe Heated ElectroSpray Ionization source (VIP-HESI) enhances micro flow rate chromatography signals in the Bruker timsTOF mass spectrometer |
title_sort | vacuum insulated probe heated electrospray ionization source (vip-hesi) enhances micro flow rate chromatography signals in the bruker timstof mass spectrometer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9949110/ https://www.ncbi.nlm.nih.gov/pubmed/36824828 http://dx.doi.org/10.1101/2023.02.15.528699 |
work_keys_str_mv | AT midhamukulk vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer AT kapilcharu vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer AT maesmichal vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer AT baxterdavidh vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer AT morroneseamusr vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer AT prokoptimothyj vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer AT moritzrobertl vacuuminsulatedprobeheatedelectrosprayionizationsourceviphesienhancesmicroflowratechromatographysignalsinthebrukertimstofmassspectrometer |