Cargando…

Case report: a transcatheter aortic valve replacement failure secondary to COVID-19 infection

BACKGROUND: Valve thrombosis is a well-documented cause of bioprosthetic valve failure. Case reports have been published of prosthetic valve thrombosis secondary to COVID-19 infection. This is the first case report of COVID-19 associated valve thrombosis in a patient with transcatheter aortic valve...

Descripción completa

Detalles Bibliográficos
Autores principales: Tacon, P Ryan, Cao, Louie, Birkeland, Kade, Kedan, Ilan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9949707/
https://www.ncbi.nlm.nih.gov/pubmed/36845835
http://dx.doi.org/10.1093/ehjcr/ytad054
_version_ 1784893004548407296
author Tacon, P Ryan
Cao, Louie
Birkeland, Kade
Kedan, Ilan
author_facet Tacon, P Ryan
Cao, Louie
Birkeland, Kade
Kedan, Ilan
author_sort Tacon, P Ryan
collection PubMed
description BACKGROUND: Valve thrombosis is a well-documented cause of bioprosthetic valve failure. Case reports have been published of prosthetic valve thrombosis secondary to COVID-19 infection. This is the first case report of COVID-19 associated valve thrombosis in a patient with transcatheter aortic valve replacement (TAVR). CASE SUMMARY: A 90-year-old female with atrial fibrillation on therapeutic apixaban and status-post TAVR presented with COVID-19 infection and was found to have severe bioprosthetic valvular regurgitation with features suggestive of valve thrombosis. She underwent valve-in-valve TAVR with resolution of valvular dysfunction. DISCUSSION: This case report contributes to a growing body of evidence describing the occurrence of thrombotic complications in patients with valve replacement and COVID-19 infection. Increased vigilance and continued investigation are warranted to better characterize thrombotic risk and to inform optimal antithrombotic strategies during COVID-19 infection.
format Online
Article
Text
id pubmed-9949707
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-99497072023-02-24 Case report: a transcatheter aortic valve replacement failure secondary to COVID-19 infection Tacon, P Ryan Cao, Louie Birkeland, Kade Kedan, Ilan Eur Heart J Case Rep Case Report BACKGROUND: Valve thrombosis is a well-documented cause of bioprosthetic valve failure. Case reports have been published of prosthetic valve thrombosis secondary to COVID-19 infection. This is the first case report of COVID-19 associated valve thrombosis in a patient with transcatheter aortic valve replacement (TAVR). CASE SUMMARY: A 90-year-old female with atrial fibrillation on therapeutic apixaban and status-post TAVR presented with COVID-19 infection and was found to have severe bioprosthetic valvular regurgitation with features suggestive of valve thrombosis. She underwent valve-in-valve TAVR with resolution of valvular dysfunction. DISCUSSION: This case report contributes to a growing body of evidence describing the occurrence of thrombotic complications in patients with valve replacement and COVID-19 infection. Increased vigilance and continued investigation are warranted to better characterize thrombotic risk and to inform optimal antithrombotic strategies during COVID-19 infection. Oxford University Press 2023-01-31 /pmc/articles/PMC9949707/ /pubmed/36845835 http://dx.doi.org/10.1093/ehjcr/ytad054 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Tacon, P Ryan
Cao, Louie
Birkeland, Kade
Kedan, Ilan
Case report: a transcatheter aortic valve replacement failure secondary to COVID-19 infection
title Case report: a transcatheter aortic valve replacement failure secondary to COVID-19 infection
title_full Case report: a transcatheter aortic valve replacement failure secondary to COVID-19 infection
title_fullStr Case report: a transcatheter aortic valve replacement failure secondary to COVID-19 infection
title_full_unstemmed Case report: a transcatheter aortic valve replacement failure secondary to COVID-19 infection
title_short Case report: a transcatheter aortic valve replacement failure secondary to COVID-19 infection
title_sort case report: a transcatheter aortic valve replacement failure secondary to covid-19 infection
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9949707/
https://www.ncbi.nlm.nih.gov/pubmed/36845835
http://dx.doi.org/10.1093/ehjcr/ytad054
work_keys_str_mv AT taconpryan casereportatranscatheteraorticvalvereplacementfailuresecondarytocovid19infection
AT caolouie casereportatranscatheteraorticvalvereplacementfailuresecondarytocovid19infection
AT birkelandkade casereportatranscatheteraorticvalvereplacementfailuresecondarytocovid19infection
AT kedanilan casereportatranscatheteraorticvalvereplacementfailuresecondarytocovid19infection