Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set

Objectives: Post-operative stent morphology of aortic dissection patients is important for performing clinical diagnosis and prognostic assessment. However, stent morphologies still need to be manually measured, which is a process prone to errors, high time consumption and difficulty in exploiting i...

Descripción completa

Detalles Bibliográficos
Autores principales: Bai, Mateng, Li, Da, Xu, Kaiyao, Ouyang, Shuyu, Yuan, Ding, Zheng, Tinghui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9951888/
https://www.ncbi.nlm.nih.gov/pubmed/36829632
http://dx.doi.org/10.3390/bioengineering10020139
_version_ 1784893491265929216
author Bai, Mateng
Li, Da
Xu, Kaiyao
Ouyang, Shuyu
Yuan, Ding
Zheng, Tinghui
author_facet Bai, Mateng
Li, Da
Xu, Kaiyao
Ouyang, Shuyu
Yuan, Ding
Zheng, Tinghui
author_sort Bai, Mateng
collection PubMed
description Objectives: Post-operative stent morphology of aortic dissection patients is important for performing clinical diagnosis and prognostic assessment. However, stent morphologies still need to be manually measured, which is a process prone to errors, high time consumption and difficulty in exploiting inter-data associations. Herein, we propose a method based on the stepwise combination of basic, non-divisible data sets to quickly obtain morphological parameters with high accuracy. Methods: We performed the 3D reconstruction of 109 post-operative follow-up CT image data from 26 patients using mimics software. By extracting the spatial locations of the basic morphological observation points on the stent, we defined a basic and non-reducible set of observation points. Further, we implemented a fully automatic stent segmentation and an observation point extraction algorithm. We analyzed the stability and accuracy of the algorithms on a test set containing 8 cases and 408 points. Based on this dataset, we calculated three morphological parameters of different complexity for the different spatial structural features exhibited by the stent. Finally, we compared the two measurement schemes in four aspects: data variability, data stability, statistical process complexity and algorithmic error. Results: The statistical results of the two methods on two low-complexity morphological parameters (spatial position of stent end and vascular stent end-slip volume) show good agreement (n = 26, P(1), P(2) < 0.001, r(1) = 0.992, r(2) = 0.988). The statistics of the proposed method for the morphological parameters of medium complexity (proximal support ring feature diameter and distal support ring feature diameter) avoid the errors caused by manual extraction, and the magnitude of this correction to the traditional method does not exceed 4 mm with an average correction of 1.38 mm. Meanwhile, our proposed automatic observation point extraction method has only 2.2% error rate on the test set, and the average spatial distance from the manually marked observation points is 0.73 mm. Thus, the proposed method is able to rapidly and accurately measure the stent circumferential deflection angle, which is highly complex and cannot be measured using traditional methods. Conclusions: The proposed method can significantly reduce the statistical observation time and information processing cost compared to the traditional morphological observation methods. Moreover, when new morphological parameters are required, one can quickly and accurately obtain the target parameters by new “combinatorial functions.” Iterative modification of the data set itself is avoided.
format Online
Article
Text
id pubmed-9951888
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99518882023-02-25 Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set Bai, Mateng Li, Da Xu, Kaiyao Ouyang, Shuyu Yuan, Ding Zheng, Tinghui Bioengineering (Basel) Article Objectives: Post-operative stent morphology of aortic dissection patients is important for performing clinical diagnosis and prognostic assessment. However, stent morphologies still need to be manually measured, which is a process prone to errors, high time consumption and difficulty in exploiting inter-data associations. Herein, we propose a method based on the stepwise combination of basic, non-divisible data sets to quickly obtain morphological parameters with high accuracy. Methods: We performed the 3D reconstruction of 109 post-operative follow-up CT image data from 26 patients using mimics software. By extracting the spatial locations of the basic morphological observation points on the stent, we defined a basic and non-reducible set of observation points. Further, we implemented a fully automatic stent segmentation and an observation point extraction algorithm. We analyzed the stability and accuracy of the algorithms on a test set containing 8 cases and 408 points. Based on this dataset, we calculated three morphological parameters of different complexity for the different spatial structural features exhibited by the stent. Finally, we compared the two measurement schemes in four aspects: data variability, data stability, statistical process complexity and algorithmic error. Results: The statistical results of the two methods on two low-complexity morphological parameters (spatial position of stent end and vascular stent end-slip volume) show good agreement (n = 26, P(1), P(2) < 0.001, r(1) = 0.992, r(2) = 0.988). The statistics of the proposed method for the morphological parameters of medium complexity (proximal support ring feature diameter and distal support ring feature diameter) avoid the errors caused by manual extraction, and the magnitude of this correction to the traditional method does not exceed 4 mm with an average correction of 1.38 mm. Meanwhile, our proposed automatic observation point extraction method has only 2.2% error rate on the test set, and the average spatial distance from the manually marked observation points is 0.73 mm. Thus, the proposed method is able to rapidly and accurately measure the stent circumferential deflection angle, which is highly complex and cannot be measured using traditional methods. Conclusions: The proposed method can significantly reduce the statistical observation time and information processing cost compared to the traditional morphological observation methods. Moreover, when new morphological parameters are required, one can quickly and accurately obtain the target parameters by new “combinatorial functions.” Iterative modification of the data set itself is avoided. MDPI 2023-01-20 /pmc/articles/PMC9951888/ /pubmed/36829632 http://dx.doi.org/10.3390/bioengineering10020139 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bai, Mateng
Li, Da
Xu, Kaiyao
Ouyang, Shuyu
Yuan, Ding
Zheng, Tinghui
Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set
title Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set
title_full Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set
title_fullStr Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set
title_full_unstemmed Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set
title_short Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set
title_sort rapid morphological measurement method of aortic dissection stent based on spatial observation point set
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9951888/
https://www.ncbi.nlm.nih.gov/pubmed/36829632
http://dx.doi.org/10.3390/bioengineering10020139
work_keys_str_mv AT baimateng rapidmorphologicalmeasurementmethodofaorticdissectionstentbasedonspatialobservationpointset
AT lida rapidmorphologicalmeasurementmethodofaorticdissectionstentbasedonspatialobservationpointset
AT xukaiyao rapidmorphologicalmeasurementmethodofaorticdissectionstentbasedonspatialobservationpointset
AT ouyangshuyu rapidmorphologicalmeasurementmethodofaorticdissectionstentbasedonspatialobservationpointset
AT yuanding rapidmorphologicalmeasurementmethodofaorticdissectionstentbasedonspatialobservationpointset
AT zhengtinghui rapidmorphologicalmeasurementmethodofaorticdissectionstentbasedonspatialobservationpointset