Cargando…
A Magnetoelectrochemical Bioassay for Highly Sensitive Sensing of Point Mutations in Interleukin-6 Gene Using TMB as a Hybridization Intercalation Indicator
Point mutations are common in the human DNA genome and are closely related to higher susceptibility to cancer diseases. Therefore, suitable methods for their sensing are of general interest. In this work, we report on a magnetic electrochemical bioassay using DNA probes tethered to streptavidin magn...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9954083/ https://www.ncbi.nlm.nih.gov/pubmed/36832006 http://dx.doi.org/10.3390/bios13020240 |
_version_ | 1784894038781984768 |
---|---|
author | Baachaoui, Sabrine Mastouri, Mohamed Meftah, Maroua Yaacoubi-Loueslati, Basma Raouafi, Noureddine |
author_facet | Baachaoui, Sabrine Mastouri, Mohamed Meftah, Maroua Yaacoubi-Loueslati, Basma Raouafi, Noureddine |
author_sort | Baachaoui, Sabrine |
collection | PubMed |
description | Point mutations are common in the human DNA genome and are closely related to higher susceptibility to cancer diseases. Therefore, suitable methods for their sensing are of general interest. In this work, we report on a magnetic electrochemical bioassay using DNA probes tethered to streptavidin magnetic beads (strep-MBs) to detect T > G single nucleotide polymorphism (SNP) within the inteleukin-6 (IL6) gene in human genomic DNA. In the presence of the target DNA fragment and tetramethylbenzidine (TMB), the electrochemical signal related to the oxidation of TMB is observed, which is much higher than the one obtained in the absence of the target. The key parameters affecting the analytical signal, such as the concentration of the biotinylated probe, its incubation time with strep-MBs, DNA hybridization time, and TMB loading, were optimized using the electrochemical signal intensity and signal-to-blank (S/B) ratio as selection criteria. Using spiked buffer solutions, the bioassay can detect the mutated allele in a wide range of concentrations (over six decades) with a low detection limit (7.3 fM). Furthermore, the bioassay displays a high specificity with high concentrations of the major allele (one mismatched), and two mismatched and non–complementary DNA. More importantly, the bioassay can detect the variation in scarcely diluted human DNA, collected from 23 donors, and can reliably distinguish between heterozygous (TG genotype) and homozygous (GG genotype) in respect to the control subjects (TT genotype), where the differences are statistically highly significant (p-value < 0.001). Thus, the bioassay is useful for cohort studies targeting one or more mutations in human DNA. |
format | Online Article Text |
id | pubmed-9954083 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99540832023-02-25 A Magnetoelectrochemical Bioassay for Highly Sensitive Sensing of Point Mutations in Interleukin-6 Gene Using TMB as a Hybridization Intercalation Indicator Baachaoui, Sabrine Mastouri, Mohamed Meftah, Maroua Yaacoubi-Loueslati, Basma Raouafi, Noureddine Biosensors (Basel) Article Point mutations are common in the human DNA genome and are closely related to higher susceptibility to cancer diseases. Therefore, suitable methods for their sensing are of general interest. In this work, we report on a magnetic electrochemical bioassay using DNA probes tethered to streptavidin magnetic beads (strep-MBs) to detect T > G single nucleotide polymorphism (SNP) within the inteleukin-6 (IL6) gene in human genomic DNA. In the presence of the target DNA fragment and tetramethylbenzidine (TMB), the electrochemical signal related to the oxidation of TMB is observed, which is much higher than the one obtained in the absence of the target. The key parameters affecting the analytical signal, such as the concentration of the biotinylated probe, its incubation time with strep-MBs, DNA hybridization time, and TMB loading, were optimized using the electrochemical signal intensity and signal-to-blank (S/B) ratio as selection criteria. Using spiked buffer solutions, the bioassay can detect the mutated allele in a wide range of concentrations (over six decades) with a low detection limit (7.3 fM). Furthermore, the bioassay displays a high specificity with high concentrations of the major allele (one mismatched), and two mismatched and non–complementary DNA. More importantly, the bioassay can detect the variation in scarcely diluted human DNA, collected from 23 donors, and can reliably distinguish between heterozygous (TG genotype) and homozygous (GG genotype) in respect to the control subjects (TT genotype), where the differences are statistically highly significant (p-value < 0.001). Thus, the bioassay is useful for cohort studies targeting one or more mutations in human DNA. MDPI 2023-02-08 /pmc/articles/PMC9954083/ /pubmed/36832006 http://dx.doi.org/10.3390/bios13020240 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Baachaoui, Sabrine Mastouri, Mohamed Meftah, Maroua Yaacoubi-Loueslati, Basma Raouafi, Noureddine A Magnetoelectrochemical Bioassay for Highly Sensitive Sensing of Point Mutations in Interleukin-6 Gene Using TMB as a Hybridization Intercalation Indicator |
title | A Magnetoelectrochemical Bioassay for Highly Sensitive Sensing of Point Mutations in Interleukin-6 Gene Using TMB as a Hybridization Intercalation Indicator |
title_full | A Magnetoelectrochemical Bioassay for Highly Sensitive Sensing of Point Mutations in Interleukin-6 Gene Using TMB as a Hybridization Intercalation Indicator |
title_fullStr | A Magnetoelectrochemical Bioassay for Highly Sensitive Sensing of Point Mutations in Interleukin-6 Gene Using TMB as a Hybridization Intercalation Indicator |
title_full_unstemmed | A Magnetoelectrochemical Bioassay for Highly Sensitive Sensing of Point Mutations in Interleukin-6 Gene Using TMB as a Hybridization Intercalation Indicator |
title_short | A Magnetoelectrochemical Bioassay for Highly Sensitive Sensing of Point Mutations in Interleukin-6 Gene Using TMB as a Hybridization Intercalation Indicator |
title_sort | magnetoelectrochemical bioassay for highly sensitive sensing of point mutations in interleukin-6 gene using tmb as a hybridization intercalation indicator |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9954083/ https://www.ncbi.nlm.nih.gov/pubmed/36832006 http://dx.doi.org/10.3390/bios13020240 |
work_keys_str_mv | AT baachaouisabrine amagnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT mastourimohamed amagnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT meftahmaroua amagnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT yaacoubiloueslatibasma amagnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT raouafinoureddine amagnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT baachaouisabrine magnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT mastourimohamed magnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT meftahmaroua magnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT yaacoubiloueslatibasma magnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator AT raouafinoureddine magnetoelectrochemicalbioassayforhighlysensitivesensingofpointmutationsininterleukin6geneusingtmbasahybridizationintercalationindicator |