Clinical and Technical Validation of Novel Bite Force Measuring Device for Functional Analysis after Mandibular Reconstruction

Bite force measuring devices that are generally suitable for edentulous patients or patients undergoing mandibular reconstruction are missing. This study assesses the validity of a new bite force measuring device (prototype of loadpad(®), novel GmbH) and evaluates its feasibility in patients after s...

Descripción completa

Detalles Bibliográficos
Autores principales: Steffen, Claudius, Duda, Katharina, Wulsten, Dag, Voss, Jan O., Koerdt, Steffen, Nahles, Susanne, Heiland, Max, Checa, Sara, Rendenbach, Carsten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955263/
https://www.ncbi.nlm.nih.gov/pubmed/36832074
http://dx.doi.org/10.3390/diagnostics13040586
_version_ 1784894309384847360
author Steffen, Claudius
Duda, Katharina
Wulsten, Dag
Voss, Jan O.
Koerdt, Steffen
Nahles, Susanne
Heiland, Max
Checa, Sara
Rendenbach, Carsten
author_facet Steffen, Claudius
Duda, Katharina
Wulsten, Dag
Voss, Jan O.
Koerdt, Steffen
Nahles, Susanne
Heiland, Max
Checa, Sara
Rendenbach, Carsten
author_sort Steffen, Claudius
collection PubMed
description Bite force measuring devices that are generally suitable for edentulous patients or patients undergoing mandibular reconstruction are missing. This study assesses the validity of a new bite force measuring device (prototype of loadpad(®), novel GmbH) and evaluates its feasibility in patients after segmental mandibular resection. Accuracy and reproducibility were analyzed with two different protocols using a universal testing machine (Z010 AllroundLine, Zwick/Roell, Ulm, Germany). Four groups were tested to evaluate the impact of silicone layers around the sensor: no silicone (“pure”), 2.0 mm soft silicone (“2-soft”), 7.0 mm soft silicone (“7-soft”) and 2.0 mm hard silicone (“2-hard”). Thereafter, the device was tested in 10 patients prospectively who underwent mandibular reconstruction using a fibula free flap. Average relative deviations of the measured force in relation to the applied load reached 0.77% (“7-soft”) to 5.28% (“2-hard”). Repeated measurements in “2-soft” revealed a mean relative deviation of 2.5% until an applied load of 600 N. Maximum bite force decreased postoperatively by 51.8% to a maximum mean bite force of 131.5 N. The novel device guarantees a high accuracy and degree of reproducibility. Furthermore, it offers new opportunities to quantify perioperative oral function after reconstructive surgery of the mandible also in edentulous patients.
format Online
Article
Text
id pubmed-9955263
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99552632023-02-25 Clinical and Technical Validation of Novel Bite Force Measuring Device for Functional Analysis after Mandibular Reconstruction Steffen, Claudius Duda, Katharina Wulsten, Dag Voss, Jan O. Koerdt, Steffen Nahles, Susanne Heiland, Max Checa, Sara Rendenbach, Carsten Diagnostics (Basel) Article Bite force measuring devices that are generally suitable for edentulous patients or patients undergoing mandibular reconstruction are missing. This study assesses the validity of a new bite force measuring device (prototype of loadpad(®), novel GmbH) and evaluates its feasibility in patients after segmental mandibular resection. Accuracy and reproducibility were analyzed with two different protocols using a universal testing machine (Z010 AllroundLine, Zwick/Roell, Ulm, Germany). Four groups were tested to evaluate the impact of silicone layers around the sensor: no silicone (“pure”), 2.0 mm soft silicone (“2-soft”), 7.0 mm soft silicone (“7-soft”) and 2.0 mm hard silicone (“2-hard”). Thereafter, the device was tested in 10 patients prospectively who underwent mandibular reconstruction using a fibula free flap. Average relative deviations of the measured force in relation to the applied load reached 0.77% (“7-soft”) to 5.28% (“2-hard”). Repeated measurements in “2-soft” revealed a mean relative deviation of 2.5% until an applied load of 600 N. Maximum bite force decreased postoperatively by 51.8% to a maximum mean bite force of 131.5 N. The novel device guarantees a high accuracy and degree of reproducibility. Furthermore, it offers new opportunities to quantify perioperative oral function after reconstructive surgery of the mandible also in edentulous patients. MDPI 2023-02-05 /pmc/articles/PMC9955263/ /pubmed/36832074 http://dx.doi.org/10.3390/diagnostics13040586 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Steffen, Claudius
Duda, Katharina
Wulsten, Dag
Voss, Jan O.
Koerdt, Steffen
Nahles, Susanne
Heiland, Max
Checa, Sara
Rendenbach, Carsten
Clinical and Technical Validation of Novel Bite Force Measuring Device for Functional Analysis after Mandibular Reconstruction
title Clinical and Technical Validation of Novel Bite Force Measuring Device for Functional Analysis after Mandibular Reconstruction
title_full Clinical and Technical Validation of Novel Bite Force Measuring Device for Functional Analysis after Mandibular Reconstruction
title_fullStr Clinical and Technical Validation of Novel Bite Force Measuring Device for Functional Analysis after Mandibular Reconstruction
title_full_unstemmed Clinical and Technical Validation of Novel Bite Force Measuring Device for Functional Analysis after Mandibular Reconstruction
title_short Clinical and Technical Validation of Novel Bite Force Measuring Device for Functional Analysis after Mandibular Reconstruction
title_sort clinical and technical validation of novel bite force measuring device for functional analysis after mandibular reconstruction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955263/
https://www.ncbi.nlm.nih.gov/pubmed/36832074
http://dx.doi.org/10.3390/diagnostics13040586
work_keys_str_mv AT steffenclaudius clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction
AT dudakatharina clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction
AT wulstendag clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction
AT vossjano clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction
AT koerdtsteffen clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction
AT nahlessusanne clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction
AT heilandmax clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction
AT checasara clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction
AT rendenbachcarsten clinicalandtechnicalvalidationofnovelbiteforcemeasuringdeviceforfunctionalanalysisaftermandibularreconstruction