Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination
This study investigated the image quality and choice of ultra-high b-value of two DWI breast-MRI research applications. The study cohort comprised 40 patients (20 malignant lesions). In addition to s-DWI with two m-b-values (b50 and b800) and three e-b-values (e-b1500, e-b2000, and e-b2500), z-DWI a...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955562/ https://www.ncbi.nlm.nih.gov/pubmed/36832095 http://dx.doi.org/10.3390/diagnostics13040607 |
_version_ | 1784894377299017728 |
---|---|
author | Hausmann, Daniel Todorski, Inga Pindur, Alexandra Weiland, Elisabeth Benkert, Thomas Bosshard, Lars Prummer, Michael Kubik-Huch, Rahel A. |
author_facet | Hausmann, Daniel Todorski, Inga Pindur, Alexandra Weiland, Elisabeth Benkert, Thomas Bosshard, Lars Prummer, Michael Kubik-Huch, Rahel A. |
author_sort | Hausmann, Daniel |
collection | PubMed |
description | This study investigated the image quality and choice of ultra-high b-value of two DWI breast-MRI research applications. The study cohort comprised 40 patients (20 malignant lesions). In addition to s-DWI with two m-b-values (b50 and b800) and three e-b-values (e-b1500, e-b2000, and e-b2500), z-DWI and IR m-b1500 DWI were applied. z-DWI was acquired with the same measured b-values and e-b-values as the standard sequence. For IR m-b1500 DWI, b50 and b1500 were measured, and e-b2000 and e-b2500 were mathematically extrapolated. Three readers used Likert scales to independently analyze all ultra-high b-values (b1500–b2500) for each DWI with regards to scan preference and image quality. ADC values were measured in all 20 lesions. z-DWI was the most preferred (54%), followed by IR m-b1500 DWI (46%). b1500 was significantly preferred over b2000 for z-DWI and IR m-b1500 DWI (p = 0.001 and p = 0.002, respectively). Lesion detection was not significantly different among sequences or b-values (p = 0.174). There were no significant differences in measured ADC values within lesions between s-DWI (ADC: 0.97 [±0.09] × 10(−3) mm(2)/s) and z-DWI (ADC: 0.99 [±0.11] × 10(−3) mm(2)/s; p = 1.000). However, there was a trend toward lower values in IR m-b1500 DWI (ADC: 0.80 [±0.06] × 10(−3) mm(2)/s) than in s-DWI (p = 0.090) and z-DWI (p = 0.110). Overall, image quality was superior and there were fewer image artifacts when using the advanced sequences (z-DWI + IR m-b1500 DWI) compared with s-DWI. Considering scan preferences, we found that the optimal combination was z-DWI with a calculated b1500, especially regarding examination time. |
format | Online Article Text |
id | pubmed-9955562 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99555622023-02-25 Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination Hausmann, Daniel Todorski, Inga Pindur, Alexandra Weiland, Elisabeth Benkert, Thomas Bosshard, Lars Prummer, Michael Kubik-Huch, Rahel A. Diagnostics (Basel) Article This study investigated the image quality and choice of ultra-high b-value of two DWI breast-MRI research applications. The study cohort comprised 40 patients (20 malignant lesions). In addition to s-DWI with two m-b-values (b50 and b800) and three e-b-values (e-b1500, e-b2000, and e-b2500), z-DWI and IR m-b1500 DWI were applied. z-DWI was acquired with the same measured b-values and e-b-values as the standard sequence. For IR m-b1500 DWI, b50 and b1500 were measured, and e-b2000 and e-b2500 were mathematically extrapolated. Three readers used Likert scales to independently analyze all ultra-high b-values (b1500–b2500) for each DWI with regards to scan preference and image quality. ADC values were measured in all 20 lesions. z-DWI was the most preferred (54%), followed by IR m-b1500 DWI (46%). b1500 was significantly preferred over b2000 for z-DWI and IR m-b1500 DWI (p = 0.001 and p = 0.002, respectively). Lesion detection was not significantly different among sequences or b-values (p = 0.174). There were no significant differences in measured ADC values within lesions between s-DWI (ADC: 0.97 [±0.09] × 10(−3) mm(2)/s) and z-DWI (ADC: 0.99 [±0.11] × 10(−3) mm(2)/s; p = 1.000). However, there was a trend toward lower values in IR m-b1500 DWI (ADC: 0.80 [±0.06] × 10(−3) mm(2)/s) than in s-DWI (p = 0.090) and z-DWI (p = 0.110). Overall, image quality was superior and there were fewer image artifacts when using the advanced sequences (z-DWI + IR m-b1500 DWI) compared with s-DWI. Considering scan preferences, we found that the optimal combination was z-DWI with a calculated b1500, especially regarding examination time. MDPI 2023-02-07 /pmc/articles/PMC9955562/ /pubmed/36832095 http://dx.doi.org/10.3390/diagnostics13040607 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hausmann, Daniel Todorski, Inga Pindur, Alexandra Weiland, Elisabeth Benkert, Thomas Bosshard, Lars Prummer, Michael Kubik-Huch, Rahel A. Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination |
title | Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination |
title_full | Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination |
title_fullStr | Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination |
title_full_unstemmed | Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination |
title_short | Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination |
title_sort | advanced diffusion-weighted imaging sequences for breast mri: comprehensive comparison of improved sequences and ultra-high b-values to identify the optimal combination |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955562/ https://www.ncbi.nlm.nih.gov/pubmed/36832095 http://dx.doi.org/10.3390/diagnostics13040607 |
work_keys_str_mv | AT hausmanndaniel advanceddiffusionweightedimagingsequencesforbreastmricomprehensivecomparisonofimprovedsequencesandultrahighbvaluestoidentifytheoptimalcombination AT todorskiinga advanceddiffusionweightedimagingsequencesforbreastmricomprehensivecomparisonofimprovedsequencesandultrahighbvaluestoidentifytheoptimalcombination AT pinduralexandra advanceddiffusionweightedimagingsequencesforbreastmricomprehensivecomparisonofimprovedsequencesandultrahighbvaluestoidentifytheoptimalcombination AT weilandelisabeth advanceddiffusionweightedimagingsequencesforbreastmricomprehensivecomparisonofimprovedsequencesandultrahighbvaluestoidentifytheoptimalcombination AT benkertthomas advanceddiffusionweightedimagingsequencesforbreastmricomprehensivecomparisonofimprovedsequencesandultrahighbvaluestoidentifytheoptimalcombination AT bosshardlars advanceddiffusionweightedimagingsequencesforbreastmricomprehensivecomparisonofimprovedsequencesandultrahighbvaluestoidentifytheoptimalcombination AT prummermichael advanceddiffusionweightedimagingsequencesforbreastmricomprehensivecomparisonofimprovedsequencesandultrahighbvaluestoidentifytheoptimalcombination AT kubikhuchrahela advanceddiffusionweightedimagingsequencesforbreastmricomprehensivecomparisonofimprovedsequencesandultrahighbvaluestoidentifytheoptimalcombination |