Cargando…
Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study
Background: Ultrasonography is widely used in neonatological practice and studies investigating the hemodynamic effects of various treatment protocols or clinical situations. On the other hand, pain causes changes in the cardiovascular system; so, in the case of ultrasonography leading to pain in ne...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955673/ https://www.ncbi.nlm.nih.gov/pubmed/36832476 http://dx.doi.org/10.3390/children10020347 |
_version_ | 1784894404654268416 |
---|---|
author | Dincer, Emre Özer, Hamza Topçuoğlu, Sevilay Karatekin, Güner |
author_facet | Dincer, Emre Özer, Hamza Topçuoğlu, Sevilay Karatekin, Güner |
author_sort | Dincer, Emre |
collection | PubMed |
description | Background: Ultrasonography is widely used in neonatological practice and studies investigating the hemodynamic effects of various treatment protocols or clinical situations. On the other hand, pain causes changes in the cardiovascular system; so, in the case of ultrasonography leading to pain in neonates, it may cause hemodynamic alterations. In this prospective study, we evaluate whether ultrasonographic application causes pain and changes in the hemodynamic system. Methods: Newborns undergoing ultrasonographic examination were enrolled in the study. Vital signs, cerebral and mesenteric tissue oxygenation (StO(2)) levels, and middle cerebral artery (MCA) Doppler measurements were recorded, and NPASS scores were calculated before and after ultrasonography. Results: We enrolled 39 patients in the study. After ultrasonography, Neonatal Pain, Agitation, and Sedation Scale (NPASS) scores were significantly higher (p < 0.01), and all vital signs (heart rate, respiratory rate, SpO(2), diastolic and systolic blood pressure; p = 0.03; p < 0.01, p < 0.01, p < 0.01, p = 0.02, p = 0.03, respectively) were altered. Cerebral (p = 0.008) and mesenteric (p = 0.039) StO(2) levels were significantly lower in the whole study group, MCA end-diastolic velocity decreased (p = 0.02), and the resistive index (p = 0.03) increased in patients whose NPASS score was >7 after ultrasonography. Conclusions: This study is the first to show that ultrasonography may cause pain in newborn patients, and alters vital signs and hemodynamic parameters. Therefore, precautions should be taken to protect newborn babies from pain during ultrasound applications, as they are already exposed to many noxious stimuli. Furthermore, pain scores should be considered in studies using ultrasonography and evaluating hemodynamic parameters to increase the reliability of the studies. |
format | Online Article Text |
id | pubmed-9955673 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99556732023-02-25 Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study Dincer, Emre Özer, Hamza Topçuoğlu, Sevilay Karatekin, Güner Children (Basel) Article Background: Ultrasonography is widely used in neonatological practice and studies investigating the hemodynamic effects of various treatment protocols or clinical situations. On the other hand, pain causes changes in the cardiovascular system; so, in the case of ultrasonography leading to pain in neonates, it may cause hemodynamic alterations. In this prospective study, we evaluate whether ultrasonographic application causes pain and changes in the hemodynamic system. Methods: Newborns undergoing ultrasonographic examination were enrolled in the study. Vital signs, cerebral and mesenteric tissue oxygenation (StO(2)) levels, and middle cerebral artery (MCA) Doppler measurements were recorded, and NPASS scores were calculated before and after ultrasonography. Results: We enrolled 39 patients in the study. After ultrasonography, Neonatal Pain, Agitation, and Sedation Scale (NPASS) scores were significantly higher (p < 0.01), and all vital signs (heart rate, respiratory rate, SpO(2), diastolic and systolic blood pressure; p = 0.03; p < 0.01, p < 0.01, p < 0.01, p = 0.02, p = 0.03, respectively) were altered. Cerebral (p = 0.008) and mesenteric (p = 0.039) StO(2) levels were significantly lower in the whole study group, MCA end-diastolic velocity decreased (p = 0.02), and the resistive index (p = 0.03) increased in patients whose NPASS score was >7 after ultrasonography. Conclusions: This study is the first to show that ultrasonography may cause pain in newborn patients, and alters vital signs and hemodynamic parameters. Therefore, precautions should be taken to protect newborn babies from pain during ultrasound applications, as they are already exposed to many noxious stimuli. Furthermore, pain scores should be considered in studies using ultrasonography and evaluating hemodynamic parameters to increase the reliability of the studies. MDPI 2023-02-10 /pmc/articles/PMC9955673/ /pubmed/36832476 http://dx.doi.org/10.3390/children10020347 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Dincer, Emre Özer, Hamza Topçuoğlu, Sevilay Karatekin, Güner Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study |
title | Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study |
title_full | Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study |
title_fullStr | Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study |
title_full_unstemmed | Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study |
title_short | Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study |
title_sort | ultrasonography causes agitation and pain leading to hemodynamic disturbance in neonates: a prospective observational study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955673/ https://www.ncbi.nlm.nih.gov/pubmed/36832476 http://dx.doi.org/10.3390/children10020347 |
work_keys_str_mv | AT dinceremre ultrasonographycausesagitationandpainleadingtohemodynamicdisturbanceinneonatesaprospectiveobservationalstudy AT ozerhamza ultrasonographycausesagitationandpainleadingtohemodynamicdisturbanceinneonatesaprospectiveobservationalstudy AT topcuoglusevilay ultrasonographycausesagitationandpainleadingtohemodynamicdisturbanceinneonatesaprospectiveobservationalstudy AT karatekinguner ultrasonographycausesagitationandpainleadingtohemodynamicdisturbanceinneonatesaprospectiveobservationalstudy |