Cargando…

Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study

Background: Ultrasonography is widely used in neonatological practice and studies investigating the hemodynamic effects of various treatment protocols or clinical situations. On the other hand, pain causes changes in the cardiovascular system; so, in the case of ultrasonography leading to pain in ne...

Descripción completa

Detalles Bibliográficos
Autores principales: Dincer, Emre, Özer, Hamza, Topçuoğlu, Sevilay, Karatekin, Güner
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955673/
https://www.ncbi.nlm.nih.gov/pubmed/36832476
http://dx.doi.org/10.3390/children10020347
_version_ 1784894404654268416
author Dincer, Emre
Özer, Hamza
Topçuoğlu, Sevilay
Karatekin, Güner
author_facet Dincer, Emre
Özer, Hamza
Topçuoğlu, Sevilay
Karatekin, Güner
author_sort Dincer, Emre
collection PubMed
description Background: Ultrasonography is widely used in neonatological practice and studies investigating the hemodynamic effects of various treatment protocols or clinical situations. On the other hand, pain causes changes in the cardiovascular system; so, in the case of ultrasonography leading to pain in neonates, it may cause hemodynamic alterations. In this prospective study, we evaluate whether ultrasonographic application causes pain and changes in the hemodynamic system. Methods: Newborns undergoing ultrasonographic examination were enrolled in the study. Vital signs, cerebral and mesenteric tissue oxygenation (StO(2)) levels, and middle cerebral artery (MCA) Doppler measurements were recorded, and NPASS scores were calculated before and after ultrasonography. Results: We enrolled 39 patients in the study. After ultrasonography, Neonatal Pain, Agitation, and Sedation Scale (NPASS) scores were significantly higher (p < 0.01), and all vital signs (heart rate, respiratory rate, SpO(2), diastolic and systolic blood pressure; p = 0.03; p < 0.01, p < 0.01, p < 0.01, p = 0.02, p = 0.03, respectively) were altered. Cerebral (p = 0.008) and mesenteric (p = 0.039) StO(2) levels were significantly lower in the whole study group, MCA end-diastolic velocity decreased (p = 0.02), and the resistive index (p = 0.03) increased in patients whose NPASS score was >7 after ultrasonography. Conclusions: This study is the first to show that ultrasonography may cause pain in newborn patients, and alters vital signs and hemodynamic parameters. Therefore, precautions should be taken to protect newborn babies from pain during ultrasound applications, as they are already exposed to many noxious stimuli. Furthermore, pain scores should be considered in studies using ultrasonography and evaluating hemodynamic parameters to increase the reliability of the studies.
format Online
Article
Text
id pubmed-9955673
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99556732023-02-25 Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study Dincer, Emre Özer, Hamza Topçuoğlu, Sevilay Karatekin, Güner Children (Basel) Article Background: Ultrasonography is widely used in neonatological practice and studies investigating the hemodynamic effects of various treatment protocols or clinical situations. On the other hand, pain causes changes in the cardiovascular system; so, in the case of ultrasonography leading to pain in neonates, it may cause hemodynamic alterations. In this prospective study, we evaluate whether ultrasonographic application causes pain and changes in the hemodynamic system. Methods: Newborns undergoing ultrasonographic examination were enrolled in the study. Vital signs, cerebral and mesenteric tissue oxygenation (StO(2)) levels, and middle cerebral artery (MCA) Doppler measurements were recorded, and NPASS scores were calculated before and after ultrasonography. Results: We enrolled 39 patients in the study. After ultrasonography, Neonatal Pain, Agitation, and Sedation Scale (NPASS) scores were significantly higher (p < 0.01), and all vital signs (heart rate, respiratory rate, SpO(2), diastolic and systolic blood pressure; p = 0.03; p < 0.01, p < 0.01, p < 0.01, p = 0.02, p = 0.03, respectively) were altered. Cerebral (p = 0.008) and mesenteric (p = 0.039) StO(2) levels were significantly lower in the whole study group, MCA end-diastolic velocity decreased (p = 0.02), and the resistive index (p = 0.03) increased in patients whose NPASS score was >7 after ultrasonography. Conclusions: This study is the first to show that ultrasonography may cause pain in newborn patients, and alters vital signs and hemodynamic parameters. Therefore, precautions should be taken to protect newborn babies from pain during ultrasound applications, as they are already exposed to many noxious stimuli. Furthermore, pain scores should be considered in studies using ultrasonography and evaluating hemodynamic parameters to increase the reliability of the studies. MDPI 2023-02-10 /pmc/articles/PMC9955673/ /pubmed/36832476 http://dx.doi.org/10.3390/children10020347 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dincer, Emre
Özer, Hamza
Topçuoğlu, Sevilay
Karatekin, Güner
Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study
title Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study
title_full Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study
title_fullStr Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study
title_full_unstemmed Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study
title_short Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study
title_sort ultrasonography causes agitation and pain leading to hemodynamic disturbance in neonates: a prospective observational study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955673/
https://www.ncbi.nlm.nih.gov/pubmed/36832476
http://dx.doi.org/10.3390/children10020347
work_keys_str_mv AT dinceremre ultrasonographycausesagitationandpainleadingtohemodynamicdisturbanceinneonatesaprospectiveobservationalstudy
AT ozerhamza ultrasonographycausesagitationandpainleadingtohemodynamicdisturbanceinneonatesaprospectiveobservationalstudy
AT topcuoglusevilay ultrasonographycausesagitationandpainleadingtohemodynamicdisturbanceinneonatesaprospectiveobservationalstudy
AT karatekinguner ultrasonographycausesagitationandpainleadingtohemodynamicdisturbanceinneonatesaprospectiveobservationalstudy