Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review

The aim of this study was to conduct a systematic literature review with a subsequent meta-analysis on the technical complications and failures of removable partial denture (RPD) therapy in the moderately reduced dentition. A systematic literature search of established medical databases, last update...

Descripción completa

Detalles Bibliográficos
Autores principales: Dawid, Marie-Theres, Moldovan, Ovidiu, Rudolph, Heike, Kuhn, Katharina, Luthardt, Ralph G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955676/
https://www.ncbi.nlm.nih.gov/pubmed/36826200
http://dx.doi.org/10.3390/dj11020055
_version_ 1784894405355765760
author Dawid, Marie-Theres
Moldovan, Ovidiu
Rudolph, Heike
Kuhn, Katharina
Luthardt, Ralph G.
author_facet Dawid, Marie-Theres
Moldovan, Ovidiu
Rudolph, Heike
Kuhn, Katharina
Luthardt, Ralph G.
author_sort Dawid, Marie-Theres
collection PubMed
description The aim of this study was to conduct a systematic literature review with a subsequent meta-analysis on the technical complications and failures of removable partial denture (RPD) therapy in the moderately reduced dentition. A systematic literature search of established medical databases, last updated 06/2022, was conducted. RCTs and prospective and retrospective studies were included that had information on technical complications and failures of RPDs, at least 15 participants, an observation period of at least two years and a drop-out rate of less than 25%. Publications were selected on the title, abstract and full-text level by at least three of the participating authors. The evidence of the included studies was classified using the GRADE system. The bias risk was determined using the RoB2 tool and the ROBINS-I tool. Of 19,592 initial hits, 43 publications were included. Predominantly, retention of the prosthesis, retention loss of anchor crowns (decementations), fractures/repairs of frameworks, denture teeth, veneering or acrylic bases, and a need for relining were reported depending on prosthesis type and observation time. Focusing on technical complications and failures, only very heterogeneous data were found and publications with the highest quality level according to GRADE were scarce. Whenever possible, data on technical complications and failures should be reported separately when referencing the tooth, the prosthesis and the patient for comparability. Prostheses with differing anchorage types should be analyzed in different groups, as the respective complications and failures differ. A precise description of the kinds of complications and failures, as well as of the resulting follow-up treatment measures, should be given.
format Online
Article
Text
id pubmed-9955676
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99556762023-02-25 Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review Dawid, Marie-Theres Moldovan, Ovidiu Rudolph, Heike Kuhn, Katharina Luthardt, Ralph G. Dent J (Basel) Systematic Review The aim of this study was to conduct a systematic literature review with a subsequent meta-analysis on the technical complications and failures of removable partial denture (RPD) therapy in the moderately reduced dentition. A systematic literature search of established medical databases, last updated 06/2022, was conducted. RCTs and prospective and retrospective studies were included that had information on technical complications and failures of RPDs, at least 15 participants, an observation period of at least two years and a drop-out rate of less than 25%. Publications were selected on the title, abstract and full-text level by at least three of the participating authors. The evidence of the included studies was classified using the GRADE system. The bias risk was determined using the RoB2 tool and the ROBINS-I tool. Of 19,592 initial hits, 43 publications were included. Predominantly, retention of the prosthesis, retention loss of anchor crowns (decementations), fractures/repairs of frameworks, denture teeth, veneering or acrylic bases, and a need for relining were reported depending on prosthesis type and observation time. Focusing on technical complications and failures, only very heterogeneous data were found and publications with the highest quality level according to GRADE were scarce. Whenever possible, data on technical complications and failures should be reported separately when referencing the tooth, the prosthesis and the patient for comparability. Prostheses with differing anchorage types should be analyzed in different groups, as the respective complications and failures differ. A precise description of the kinds of complications and failures, as well as of the resulting follow-up treatment measures, should be given. MDPI 2023-02-20 /pmc/articles/PMC9955676/ /pubmed/36826200 http://dx.doi.org/10.3390/dj11020055 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Dawid, Marie-Theres
Moldovan, Ovidiu
Rudolph, Heike
Kuhn, Katharina
Luthardt, Ralph G.
Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review
title Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review
title_full Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review
title_fullStr Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review
title_full_unstemmed Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review
title_short Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review
title_sort technical complications of removable partial dentures in the moderately reduced dentition: a systematic review
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955676/
https://www.ncbi.nlm.nih.gov/pubmed/36826200
http://dx.doi.org/10.3390/dj11020055
work_keys_str_mv AT dawidmarietheres technicalcomplicationsofremovablepartialdenturesinthemoderatelyreduceddentitionasystematicreview
AT moldovanovidiu technicalcomplicationsofremovablepartialdenturesinthemoderatelyreduceddentitionasystematicreview
AT rudolphheike technicalcomplicationsofremovablepartialdenturesinthemoderatelyreduceddentitionasystematicreview
AT kuhnkatharina technicalcomplicationsofremovablepartialdenturesinthemoderatelyreduceddentitionasystematicreview
AT luthardtralphg technicalcomplicationsofremovablepartialdenturesinthemoderatelyreduceddentitionasystematicreview