Cargando…

Validation of the Measuring Protocol for the Infraspinatus Muscle with M-Mode Ultrasound in Asymptomatic Subjects. Intra- and Inter-examiner Reliability Study

M-mode ultrasound is a reliable and valid instrument for assessing muscle activity. However, it has not been studied in any of the muscles belonging to the shoulder joint complex, particularly in the infraspinatus muscle. The aim of this study is the validation of the infraspinatus muscle activity m...

Descripción completa

Detalles Bibliográficos
Autores principales: Ortega-Santamaría, Marina, Torralbo-Álvarez-Novoa, María-Eugenia, Cuenca-Zaldívar, Juan-Nicolás, Naranjo-Cinto, Fermin, Fernández-Carnero, Samuel, Pecos-Martín, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955823/
https://www.ncbi.nlm.nih.gov/pubmed/36832070
http://dx.doi.org/10.3390/diagnostics13040582
_version_ 1784894441658515456
author Ortega-Santamaría, Marina
Torralbo-Álvarez-Novoa, María-Eugenia
Cuenca-Zaldívar, Juan-Nicolás
Naranjo-Cinto, Fermin
Fernández-Carnero, Samuel
Pecos-Martín, Daniel
author_facet Ortega-Santamaría, Marina
Torralbo-Álvarez-Novoa, María-Eugenia
Cuenca-Zaldívar, Juan-Nicolás
Naranjo-Cinto, Fermin
Fernández-Carnero, Samuel
Pecos-Martín, Daniel
author_sort Ortega-Santamaría, Marina
collection PubMed
description M-mode ultrasound is a reliable and valid instrument for assessing muscle activity. However, it has not been studied in any of the muscles belonging to the shoulder joint complex, particularly in the infraspinatus muscle. The aim of this study is the validation of the infraspinatus muscle activity measurement protocol with the M-mode ultrasound in asymptomatic subjects. Sixty asymptomatic volunteers were evaluated by two physiotherapists who were blinded; each of them carried out three measurements with the M-mode ultrasound in infraspinatus muscle and analysed the muscle thickness at rest and contraction, velocity of muscle activation and relaxation and Maximum Voluntary Isometric Contraction (MVIC). Intra-observer reliability was significant in both observers, showing good thickness at rest (ICC = 0.833–0.889), thickness in contraction (ICC = 0.861–0.933) and MVIC (ICC = 0.875–0.813); moderate in the activation velocity (ICC = 0.499–0.547) and relaxation velocity (ICC = 0.457–0.606). The inter-observer reliability also had good thickness at rest (ICC = 0.797), thickness in contraction (ICC = 0.89) and MVIC (ICC = 0.84); poor in relaxation time variable (ICC = 0.474) and not significant at the activation velocity (ICC = 0). The muscle activity measurement protocol of the infraspinatus muscle measured with M-mode ultrasound has been found to be reliable in asymptomatic subjects, for both the intra-examiner and inter-examiner.
format Online
Article
Text
id pubmed-9955823
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99558232023-02-25 Validation of the Measuring Protocol for the Infraspinatus Muscle with M-Mode Ultrasound in Asymptomatic Subjects. Intra- and Inter-examiner Reliability Study Ortega-Santamaría, Marina Torralbo-Álvarez-Novoa, María-Eugenia Cuenca-Zaldívar, Juan-Nicolás Naranjo-Cinto, Fermin Fernández-Carnero, Samuel Pecos-Martín, Daniel Diagnostics (Basel) Article M-mode ultrasound is a reliable and valid instrument for assessing muscle activity. However, it has not been studied in any of the muscles belonging to the shoulder joint complex, particularly in the infraspinatus muscle. The aim of this study is the validation of the infraspinatus muscle activity measurement protocol with the M-mode ultrasound in asymptomatic subjects. Sixty asymptomatic volunteers were evaluated by two physiotherapists who were blinded; each of them carried out three measurements with the M-mode ultrasound in infraspinatus muscle and analysed the muscle thickness at rest and contraction, velocity of muscle activation and relaxation and Maximum Voluntary Isometric Contraction (MVIC). Intra-observer reliability was significant in both observers, showing good thickness at rest (ICC = 0.833–0.889), thickness in contraction (ICC = 0.861–0.933) and MVIC (ICC = 0.875–0.813); moderate in the activation velocity (ICC = 0.499–0.547) and relaxation velocity (ICC = 0.457–0.606). The inter-observer reliability also had good thickness at rest (ICC = 0.797), thickness in contraction (ICC = 0.89) and MVIC (ICC = 0.84); poor in relaxation time variable (ICC = 0.474) and not significant at the activation velocity (ICC = 0). The muscle activity measurement protocol of the infraspinatus muscle measured with M-mode ultrasound has been found to be reliable in asymptomatic subjects, for both the intra-examiner and inter-examiner. MDPI 2023-02-04 /pmc/articles/PMC9955823/ /pubmed/36832070 http://dx.doi.org/10.3390/diagnostics13040582 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ortega-Santamaría, Marina
Torralbo-Álvarez-Novoa, María-Eugenia
Cuenca-Zaldívar, Juan-Nicolás
Naranjo-Cinto, Fermin
Fernández-Carnero, Samuel
Pecos-Martín, Daniel
Validation of the Measuring Protocol for the Infraspinatus Muscle with M-Mode Ultrasound in Asymptomatic Subjects. Intra- and Inter-examiner Reliability Study
title Validation of the Measuring Protocol for the Infraspinatus Muscle with M-Mode Ultrasound in Asymptomatic Subjects. Intra- and Inter-examiner Reliability Study
title_full Validation of the Measuring Protocol for the Infraspinatus Muscle with M-Mode Ultrasound in Asymptomatic Subjects. Intra- and Inter-examiner Reliability Study
title_fullStr Validation of the Measuring Protocol for the Infraspinatus Muscle with M-Mode Ultrasound in Asymptomatic Subjects. Intra- and Inter-examiner Reliability Study
title_full_unstemmed Validation of the Measuring Protocol for the Infraspinatus Muscle with M-Mode Ultrasound in Asymptomatic Subjects. Intra- and Inter-examiner Reliability Study
title_short Validation of the Measuring Protocol for the Infraspinatus Muscle with M-Mode Ultrasound in Asymptomatic Subjects. Intra- and Inter-examiner Reliability Study
title_sort validation of the measuring protocol for the infraspinatus muscle with m-mode ultrasound in asymptomatic subjects. intra- and inter-examiner reliability study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9955823/
https://www.ncbi.nlm.nih.gov/pubmed/36832070
http://dx.doi.org/10.3390/diagnostics13040582
work_keys_str_mv AT ortegasantamariamarina validationofthemeasuringprotocolfortheinfraspinatusmusclewithmmodeultrasoundinasymptomaticsubjectsintraandinterexaminerreliabilitystudy
AT torralboalvareznovoamariaeugenia validationofthemeasuringprotocolfortheinfraspinatusmusclewithmmodeultrasoundinasymptomaticsubjectsintraandinterexaminerreliabilitystudy
AT cuencazaldivarjuannicolas validationofthemeasuringprotocolfortheinfraspinatusmusclewithmmodeultrasoundinasymptomaticsubjectsintraandinterexaminerreliabilitystudy
AT naranjocintofermin validationofthemeasuringprotocolfortheinfraspinatusmusclewithmmodeultrasoundinasymptomaticsubjectsintraandinterexaminerreliabilitystudy
AT fernandezcarnerosamuel validationofthemeasuringprotocolfortheinfraspinatusmusclewithmmodeultrasoundinasymptomaticsubjectsintraandinterexaminerreliabilitystudy
AT pecosmartindaniel validationofthemeasuringprotocolfortheinfraspinatusmusclewithmmodeultrasoundinasymptomaticsubjectsintraandinterexaminerreliabilitystudy