Cargando…
Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up
PURPOSE: Highly crosslinked polyethylene (HXLPE) was introduced in total knee arthroplasty (TKA) to reduce wear and consequent revisions for loosening due to conventional polyethylene (CPE) wear. This study aims to analyse whether HXLPE is as safe as CPE and could improve the TKA clinical and radiol...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958150/ https://www.ncbi.nlm.nih.gov/pubmed/36409325 http://dx.doi.org/10.1007/s00167-022-07226-6 |
_version_ | 1784894964759527424 |
---|---|
author | Giustra, Fortunato Bistolfi, Alessandro Bosco, Francesco Fresia, Nicolò Sabatini, Luigi Berchialla, Paola Sciannameo, Veronica Massè, Alessandro |
author_facet | Giustra, Fortunato Bistolfi, Alessandro Bosco, Francesco Fresia, Nicolò Sabatini, Luigi Berchialla, Paola Sciannameo, Veronica Massè, Alessandro |
author_sort | Giustra, Fortunato |
collection | PubMed |
description | PURPOSE: Highly crosslinked polyethylene (HXLPE) was introduced in total knee arthroplasty (TKA) to reduce wear and consequent revisions for loosening due to conventional polyethylene (CPE) wear. This study aims to analyse whether HXLPE is as safe as CPE and could improve the TKA clinical and radiological results in a long-term follow-up. METHODS: This retrospective study included all consecutive starting series of 223 patients with severe primary knee osteoarthritis (OA), with a minimum follow-up of 10 years treated between July 1st, 2007, and July 31st, 2010. After excluding patients who did not respect the inclusion and exclusion criteria, 128 patients were included in the analysis of this study. The patients were then divided into two groups according to the type of polyethylene (PE) implanted: CPE or HXLPE liners. All patients were evaluated for clinical and radiological parameters, causes and revision rates related to the type of PE implanted. RESULTS: HXLPE appears to be as safe as CPE in TKA, reporting no higher revisions for osteolysis, prosthesis loosening, infection, and mechanical failure. Nevertheless, no statistically significant differences were found between the two groups in the clinical and radiological outcomes evaluated. CONCLUSIONS: Clinical, radiological results, and revision rates are similar between HXLPE and CPE in TKA after 10 years of follow-up, although HXLPE benefits remain controversial. LEVEL OF EVIDENCE: III. |
format | Online Article Text |
id | pubmed-9958150 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-99581502023-02-26 Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up Giustra, Fortunato Bistolfi, Alessandro Bosco, Francesco Fresia, Nicolò Sabatini, Luigi Berchialla, Paola Sciannameo, Veronica Massè, Alessandro Knee Surg Sports Traumatol Arthrosc Knee PURPOSE: Highly crosslinked polyethylene (HXLPE) was introduced in total knee arthroplasty (TKA) to reduce wear and consequent revisions for loosening due to conventional polyethylene (CPE) wear. This study aims to analyse whether HXLPE is as safe as CPE and could improve the TKA clinical and radiological results in a long-term follow-up. METHODS: This retrospective study included all consecutive starting series of 223 patients with severe primary knee osteoarthritis (OA), with a minimum follow-up of 10 years treated between July 1st, 2007, and July 31st, 2010. After excluding patients who did not respect the inclusion and exclusion criteria, 128 patients were included in the analysis of this study. The patients were then divided into two groups according to the type of polyethylene (PE) implanted: CPE or HXLPE liners. All patients were evaluated for clinical and radiological parameters, causes and revision rates related to the type of PE implanted. RESULTS: HXLPE appears to be as safe as CPE in TKA, reporting no higher revisions for osteolysis, prosthesis loosening, infection, and mechanical failure. Nevertheless, no statistically significant differences were found between the two groups in the clinical and radiological outcomes evaluated. CONCLUSIONS: Clinical, radiological results, and revision rates are similar between HXLPE and CPE in TKA after 10 years of follow-up, although HXLPE benefits remain controversial. LEVEL OF EVIDENCE: III. Springer Berlin Heidelberg 2022-11-21 2023 /pmc/articles/PMC9958150/ /pubmed/36409325 http://dx.doi.org/10.1007/s00167-022-07226-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Knee Giustra, Fortunato Bistolfi, Alessandro Bosco, Francesco Fresia, Nicolò Sabatini, Luigi Berchialla, Paola Sciannameo, Veronica Massè, Alessandro Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up |
title | Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up |
title_full | Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up |
title_fullStr | Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up |
title_full_unstemmed | Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up |
title_short | Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up |
title_sort | highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958150/ https://www.ncbi.nlm.nih.gov/pubmed/36409325 http://dx.doi.org/10.1007/s00167-022-07226-6 |
work_keys_str_mv | AT giustrafortunato highlycrosslinkedpolyethyleneversusconventionalpolyethyleneinprimarytotalkneearthroplastycomparableclinicalandradiologicalresultsata10yearfollowup AT bistolfialessandro highlycrosslinkedpolyethyleneversusconventionalpolyethyleneinprimarytotalkneearthroplastycomparableclinicalandradiologicalresultsata10yearfollowup AT boscofrancesco highlycrosslinkedpolyethyleneversusconventionalpolyethyleneinprimarytotalkneearthroplastycomparableclinicalandradiologicalresultsata10yearfollowup AT fresianicolo highlycrosslinkedpolyethyleneversusconventionalpolyethyleneinprimarytotalkneearthroplastycomparableclinicalandradiologicalresultsata10yearfollowup AT sabatiniluigi highlycrosslinkedpolyethyleneversusconventionalpolyethyleneinprimarytotalkneearthroplastycomparableclinicalandradiologicalresultsata10yearfollowup AT berchiallapaola highlycrosslinkedpolyethyleneversusconventionalpolyethyleneinprimarytotalkneearthroplastycomparableclinicalandradiologicalresultsata10yearfollowup AT sciannameoveronica highlycrosslinkedpolyethyleneversusconventionalpolyethyleneinprimarytotalkneearthroplastycomparableclinicalandradiologicalresultsata10yearfollowup AT massealessandro highlycrosslinkedpolyethyleneversusconventionalpolyethyleneinprimarytotalkneearthroplastycomparableclinicalandradiologicalresultsata10yearfollowup |