Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up
PURPOSE: Highly crosslinked polyethylene (HXLPE) was introduced in total knee arthroplasty (TKA) to reduce wear and consequent revisions for loosening due to conventional polyethylene (CPE) wear. This study aims to analyse whether HXLPE is as safe as CPE and could improve the TKA clinical and radiol...
Autores principales: | Giustra, Fortunato, Bistolfi, Alessandro, Bosco, Francesco, Fresia, Nicolò, Sabatini, Luigi, Berchialla, Paola, Sciannameo, Veronica, Massè, Alessandro |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958150/ https://www.ncbi.nlm.nih.gov/pubmed/36409325 http://dx.doi.org/10.1007/s00167-022-07226-6 |
Ejemplares similares
-
Comparable results between crosslinked polyethylene and conventional ultra-high molecular weight polyethylene implanted in total knee arthroplasty: systematic review and meta-analysis of randomised clinical trials
por: Bistolfi, Alessandro, et al.
Publicado: (2022) -
The role of isolated polyethylene exchange in total knee arthroplasty
por: Pang, Hee-Nee, et al.
Publicado: (2017) -
No Significant Differences in Clinical and Radiographic Outcomes between PCL Retained or Sacrificed Kinematic Aligned Medial Pivot Total Knee Arthroplasty in Varus Knee
por: Giustra, Fortunato, et al.
Publicado: (2022) -
The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
por: Cowie, R. M., et al.
Publicado: (2019) -
Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model
por: Scott, C. E. H., et al.
Publicado: (2017)