Minifragment plating of the fibula in unstable ankle fractures
INTRODUCTION: Only 6.4–17% of the load is transmitted through the fibula when weight-bearing. Plate fixation of distal fibular fractures using minifragments (≤ 2.8 mm) could lead to similar reduction with less implant removal (IR) rates, compared to small-fragment plates (3.5 mm). We hypothesized th...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958153/ https://www.ncbi.nlm.nih.gov/pubmed/35224664 http://dx.doi.org/10.1007/s00402-022-04397-2 |
_version_ | 1784894965243969536 |
---|---|
author | Penning, D. Jonker, C. A. L. Buijsman, R. Halm, J. A. Schepers, T. |
author_facet | Penning, D. Jonker, C. A. L. Buijsman, R. Halm, J. A. Schepers, T. |
author_sort | Penning, D. |
collection | PubMed |
description | INTRODUCTION: Only 6.4–17% of the load is transmitted through the fibula when weight-bearing. Plate fixation of distal fibular fractures using minifragments (≤ 2.8 mm) could lead to similar reduction with less implant removal (IR) rates, compared to small-fragment plates (3.5 mm). We hypothesized that the use of minifragment plates is at least similar in unscheduled secondary surgery. MATERIALS AND METHODS: In this retrospective cohort study, all patients with surgically treated distal fibular fractures between October 2015 and March 2021 were included. Patients treated with plate fixation using minifragments and patients treated with small-fragment plates were compared regarding the following outcomes: secondary dislocation, malreduction, implant malposition, nonunion, surgical site infections (SSI) and IR. RESULTS: Sixty-five patients (54.2%) received a minifragment implant (≤ 2.8 mm) and 55 patients (45.8%) received a small-fragment implant (3.5 mm). There were no patients needing secondary surgery in the minifragment group compared to 9 patients following fixation using small-fragment implants (3 with secondary dislocation, 5 with malreduction and 1 with malposition, p = 0.001). SSI rates were 3.1% for minifragment and 9.1% for small-fragment implants (p = 0.161). Implant removal was performed significantly less often following use of minifragment implants (17.8% and 53.2%, p < 0.001). CONCLUSIONS: In this cohort, minifragment plate fixation for distal fibular fractures is an adequate fixation method offering stable fixation with significant lower need for implant removal and comparable complications to small-fragment plates, although an adequately powered randomized controlled study is needed for implementation in a clinical setting. LEVEL OF EVIDENCE: Therapeutic, III. |
format | Online Article Text |
id | pubmed-9958153 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-99581532023-02-26 Minifragment plating of the fibula in unstable ankle fractures Penning, D. Jonker, C. A. L. Buijsman, R. Halm, J. A. Schepers, T. Arch Orthop Trauma Surg Trauma Surgery INTRODUCTION: Only 6.4–17% of the load is transmitted through the fibula when weight-bearing. Plate fixation of distal fibular fractures using minifragments (≤ 2.8 mm) could lead to similar reduction with less implant removal (IR) rates, compared to small-fragment plates (3.5 mm). We hypothesized that the use of minifragment plates is at least similar in unscheduled secondary surgery. MATERIALS AND METHODS: In this retrospective cohort study, all patients with surgically treated distal fibular fractures between October 2015 and March 2021 were included. Patients treated with plate fixation using minifragments and patients treated with small-fragment plates were compared regarding the following outcomes: secondary dislocation, malreduction, implant malposition, nonunion, surgical site infections (SSI) and IR. RESULTS: Sixty-five patients (54.2%) received a minifragment implant (≤ 2.8 mm) and 55 patients (45.8%) received a small-fragment implant (3.5 mm). There were no patients needing secondary surgery in the minifragment group compared to 9 patients following fixation using small-fragment implants (3 with secondary dislocation, 5 with malreduction and 1 with malposition, p = 0.001). SSI rates were 3.1% for minifragment and 9.1% for small-fragment implants (p = 0.161). Implant removal was performed significantly less often following use of minifragment implants (17.8% and 53.2%, p < 0.001). CONCLUSIONS: In this cohort, minifragment plate fixation for distal fibular fractures is an adequate fixation method offering stable fixation with significant lower need for implant removal and comparable complications to small-fragment plates, although an adequately powered randomized controlled study is needed for implementation in a clinical setting. LEVEL OF EVIDENCE: Therapeutic, III. Springer Berlin Heidelberg 2022-02-28 2023 /pmc/articles/PMC9958153/ /pubmed/35224664 http://dx.doi.org/10.1007/s00402-022-04397-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Trauma Surgery Penning, D. Jonker, C. A. L. Buijsman, R. Halm, J. A. Schepers, T. Minifragment plating of the fibula in unstable ankle fractures |
title | Minifragment plating of the fibula in unstable ankle fractures |
title_full | Minifragment plating of the fibula in unstable ankle fractures |
title_fullStr | Minifragment plating of the fibula in unstable ankle fractures |
title_full_unstemmed | Minifragment plating of the fibula in unstable ankle fractures |
title_short | Minifragment plating of the fibula in unstable ankle fractures |
title_sort | minifragment plating of the fibula in unstable ankle fractures |
topic | Trauma Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958153/ https://www.ncbi.nlm.nih.gov/pubmed/35224664 http://dx.doi.org/10.1007/s00402-022-04397-2 |
work_keys_str_mv | AT penningd minifragmentplatingofthefibulainunstableanklefractures AT jonkercal minifragmentplatingofthefibulainunstableanklefractures AT buijsmanr minifragmentplatingofthefibulainunstableanklefractures AT halmja minifragmentplatingofthefibulainunstableanklefractures AT scheperst minifragmentplatingofthefibulainunstableanklefractures |