Cargando…

Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension

PURPOSE: In contrast to peridialytic blood pressure (BP), intradialytic and home BP measurements are accurate metrics of ambulatory BP load in hemodialysis patients. This study assessed the agreement of peridialytic, intradialytic, and scheduled interdialytic recordings with 44-h BP in a distinct he...

Descripción completa

Detalles Bibliográficos
Autores principales: Theodorakopoulou, Marieta P., Alexandrou, Maria-Eleni, Iatridi, Fotini, Karpetas, Antonios, Geladari, Virginia, Pella, Eva, Alexiou, Sophia, Sidiropoulou, Maria, Ziaka, Stavroula, Papagianni, Aikaterini, Sarafidis, Pantelis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958170/
https://www.ncbi.nlm.nih.gov/pubmed/36153412
http://dx.doi.org/10.1007/s11255-022-03369-0
_version_ 1784894969237995520
author Theodorakopoulou, Marieta P.
Alexandrou, Maria-Eleni
Iatridi, Fotini
Karpetas, Antonios
Geladari, Virginia
Pella, Eva
Alexiou, Sophia
Sidiropoulou, Maria
Ziaka, Stavroula
Papagianni, Aikaterini
Sarafidis, Pantelis
author_facet Theodorakopoulou, Marieta P.
Alexandrou, Maria-Eleni
Iatridi, Fotini
Karpetas, Antonios
Geladari, Virginia
Pella, Eva
Alexiou, Sophia
Sidiropoulou, Maria
Ziaka, Stavroula
Papagianni, Aikaterini
Sarafidis, Pantelis
author_sort Theodorakopoulou, Marieta P.
collection PubMed
description PURPOSE: In contrast to peridialytic blood pressure (BP), intradialytic and home BP measurements are accurate metrics of ambulatory BP load in hemodialysis patients. This study assessed the agreement of peridialytic, intradialytic, and scheduled interdialytic recordings with 44-h BP in a distinct hemodialysis population, patients with intradialytic hypertension (IDH). METHODS: This study included 45 IDH patients with valid 48-h ABPM and 197 without IDH. With 44-h BP used as reference method, we tested the accuracy of the following BP metrics: Pre- and post-dialysis, mean and median intradialytic, mean intradialytic plus pre/post-dialysis, and scheduled interdialytic BP (out-of-dialysis day: mean of 8:00am/8:00 pm readings). RESULTS: In IDH patients, peridialytic and intradialytic BP metrics showed at best moderate correlations, while averaged interdialytic SBP/DBP exhibited strong correlation (r = 0.882/r = 0.855) with 44-h SBP/DBP. Bland–Altman plots showed large between-method-difference for peri- and intradialytic-BP, but only + 0.7 mmHg between-method difference and good 95% limits of agreement for averaged interdialytic SBP. The sensitivity/specificity and κ-statistic for diagnosing 44-h SBP ≥ 130 mmHg were low for pre-dialysis (72.5/40.0%, κ-statistic = 0.074) and post-dialysis (90.0/0.0%, κ-statistic = − 0.110), mean intradialytic (85.0/40.0%, κ-statistic = 0.198), median intradialytic (85.0/60.0%, κ-statistic = 0.333), and intradialytic plus pre/post-dialysis SBP (85.0/20.0%, κ-statistic = 0.043). Averaged interdialytic SBP showed high sensitivity/specificity (97.5/80.0%) and strong agreement (κ-statistic = 0.775). In ROC analyses, scheduled interdialytic SBP/DBP had the highest AUC (0.967/0.951), sensitivity (90.0/88.0%), and specificity (100.0/90.0%). CONCLUSION: In IDH patients, only averaged scheduled interdialytic but not pre- and post-dialysis, nor intradialytic BP recordings show reasonable agreement with ABPM. Interdialytic BP recordings only could be used for hypertension diagnosis and management in these subjects. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11255-022-03369-0.
format Online
Article
Text
id pubmed-9958170
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-99581702023-02-26 Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension Theodorakopoulou, Marieta P. Alexandrou, Maria-Eleni Iatridi, Fotini Karpetas, Antonios Geladari, Virginia Pella, Eva Alexiou, Sophia Sidiropoulou, Maria Ziaka, Stavroula Papagianni, Aikaterini Sarafidis, Pantelis Int Urol Nephrol Nephrology - Original Paper PURPOSE: In contrast to peridialytic blood pressure (BP), intradialytic and home BP measurements are accurate metrics of ambulatory BP load in hemodialysis patients. This study assessed the agreement of peridialytic, intradialytic, and scheduled interdialytic recordings with 44-h BP in a distinct hemodialysis population, patients with intradialytic hypertension (IDH). METHODS: This study included 45 IDH patients with valid 48-h ABPM and 197 without IDH. With 44-h BP used as reference method, we tested the accuracy of the following BP metrics: Pre- and post-dialysis, mean and median intradialytic, mean intradialytic plus pre/post-dialysis, and scheduled interdialytic BP (out-of-dialysis day: mean of 8:00am/8:00 pm readings). RESULTS: In IDH patients, peridialytic and intradialytic BP metrics showed at best moderate correlations, while averaged interdialytic SBP/DBP exhibited strong correlation (r = 0.882/r = 0.855) with 44-h SBP/DBP. Bland–Altman plots showed large between-method-difference for peri- and intradialytic-BP, but only + 0.7 mmHg between-method difference and good 95% limits of agreement for averaged interdialytic SBP. The sensitivity/specificity and κ-statistic for diagnosing 44-h SBP ≥ 130 mmHg were low for pre-dialysis (72.5/40.0%, κ-statistic = 0.074) and post-dialysis (90.0/0.0%, κ-statistic = − 0.110), mean intradialytic (85.0/40.0%, κ-statistic = 0.198), median intradialytic (85.0/60.0%, κ-statistic = 0.333), and intradialytic plus pre/post-dialysis SBP (85.0/20.0%, κ-statistic = 0.043). Averaged interdialytic SBP showed high sensitivity/specificity (97.5/80.0%) and strong agreement (κ-statistic = 0.775). In ROC analyses, scheduled interdialytic SBP/DBP had the highest AUC (0.967/0.951), sensitivity (90.0/88.0%), and specificity (100.0/90.0%). CONCLUSION: In IDH patients, only averaged scheduled interdialytic but not pre- and post-dialysis, nor intradialytic BP recordings show reasonable agreement with ABPM. Interdialytic BP recordings only could be used for hypertension diagnosis and management in these subjects. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11255-022-03369-0. Springer Netherlands 2022-09-24 2023 /pmc/articles/PMC9958170/ /pubmed/36153412 http://dx.doi.org/10.1007/s11255-022-03369-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Nephrology - Original Paper
Theodorakopoulou, Marieta P.
Alexandrou, Maria-Eleni
Iatridi, Fotini
Karpetas, Antonios
Geladari, Virginia
Pella, Eva
Alexiou, Sophia
Sidiropoulou, Maria
Ziaka, Stavroula
Papagianni, Aikaterini
Sarafidis, Pantelis
Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension
title Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension
title_full Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension
title_fullStr Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension
title_full_unstemmed Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension
title_short Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension
title_sort peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension
topic Nephrology - Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958170/
https://www.ncbi.nlm.nih.gov/pubmed/36153412
http://dx.doi.org/10.1007/s11255-022-03369-0
work_keys_str_mv AT theodorakopouloumarietap peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT alexandroumariaeleni peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT iatridifotini peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT karpetasantonios peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT geladarivirginia peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT pellaeva peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT alexiousophia peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT sidiropouloumaria peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT ziakastavroula peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT papagianniaikaterini peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension
AT sarafidispantelis peridialyticandintradialyticbloodpressuremetricsarenotvalidestimatesof44hambulatorybloodpressureinpatientswithintradialytichypertension