Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?

Temporal modulation sensitivity has been studied extensively for cochlear implant (CI) users due to its strong correlation to speech recognition outcomes. Previous studies reported that temporal modulation detection thresholds (MDTs) vary across the tonotopic axis and attributed this variation to pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Ning, Shi, Xuyang, Dixit, Omkar, Firszt, Jill B., Holden, Timothy A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958279/
https://www.ncbi.nlm.nih.gov/pubmed/36852047
http://dx.doi.org/10.1016/j.heliyon.2022.e12467
_version_ 1784894988115509248
author Zhou, Ning
Shi, Xuyang
Dixit, Omkar
Firszt, Jill B.
Holden, Timothy A.
author_facet Zhou, Ning
Shi, Xuyang
Dixit, Omkar
Firszt, Jill B.
Holden, Timothy A.
author_sort Zhou, Ning
collection PubMed
description Temporal modulation sensitivity has been studied extensively for cochlear implant (CI) users due to its strong correlation to speech recognition outcomes. Previous studies reported that temporal modulation detection thresholds (MDTs) vary across the tonotopic axis and attributed this variation to patchy neural survival. However, correlates of neural health identified in animal models depend on electrode position in humans. Nonetheless, the relationship between MDT and electrode location has not been explored. We tested 13 ears for the effect of distance on modulation sensitivity, specifically targeting the question of whether electrodes closer to the modiolus are universally beneficial. Participants in this study were postlingually deafened and users of Cochlear Nucleus CIs. The distance of each electrode from the medial wall (MW) of the cochlea and mid-modiolar axis (MMA) was measured from scans obtained using computerized tomography (CT) imaging. The distance measures were correlated with slopes of spatial tuning curves measured on selected electrodes to investigate if electrode position accounts, at least in part, for the width of neural excitation. In accordance with previous findings, electrode position explained 24% of the variance in slopes of the spatial tuning curves. All functioning electrodes were also measured for MDTs. Five ears showed a positive correlation between MDTs and at least one distance measure across the array; 6 ears showed negative correlations and the remaining two ears showed no relationship. The ears showing positive MDT-distance correlations, thus benefiting from electrodes being close to the neural elements, were those who performed better on the two speech recognition measures, i.e., speech reception thresholds (SRTs) and recognition of the AzBio sentences. These results could suggest that ears able to take advantage of the proximal placement of electrodes are likely to have better speech recognition outcomes. Previous histological studies of humans demonstrated that speech recognition is correlated with spiral ganglion cell counts. Alternatively, ears with good speech recognition outcomes may have good overall neural health, which is a precondition for close electrodes to produce spatially confined neural excitation patterns that facilitate modulation sensitivity. These findings suggest that the methods to reduce channel interaction, e.g., perimodiolar electrode array or current focusing, may only be beneficial for a subgroup of CI users. Additionally, it suggests that estimating neural survival preoperatively is important for choosing the most appropriate electrode array type (perimodiolar vs. lateral wall) for optimal implant function.
format Online
Article
Text
id pubmed-9958279
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-99582792023-02-26 Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better? Zhou, Ning Shi, Xuyang Dixit, Omkar Firszt, Jill B. Holden, Timothy A. Heliyon Research Article Temporal modulation sensitivity has been studied extensively for cochlear implant (CI) users due to its strong correlation to speech recognition outcomes. Previous studies reported that temporal modulation detection thresholds (MDTs) vary across the tonotopic axis and attributed this variation to patchy neural survival. However, correlates of neural health identified in animal models depend on electrode position in humans. Nonetheless, the relationship between MDT and electrode location has not been explored. We tested 13 ears for the effect of distance on modulation sensitivity, specifically targeting the question of whether electrodes closer to the modiolus are universally beneficial. Participants in this study were postlingually deafened and users of Cochlear Nucleus CIs. The distance of each electrode from the medial wall (MW) of the cochlea and mid-modiolar axis (MMA) was measured from scans obtained using computerized tomography (CT) imaging. The distance measures were correlated with slopes of spatial tuning curves measured on selected electrodes to investigate if electrode position accounts, at least in part, for the width of neural excitation. In accordance with previous findings, electrode position explained 24% of the variance in slopes of the spatial tuning curves. All functioning electrodes were also measured for MDTs. Five ears showed a positive correlation between MDTs and at least one distance measure across the array; 6 ears showed negative correlations and the remaining two ears showed no relationship. The ears showing positive MDT-distance correlations, thus benefiting from electrodes being close to the neural elements, were those who performed better on the two speech recognition measures, i.e., speech reception thresholds (SRTs) and recognition of the AzBio sentences. These results could suggest that ears able to take advantage of the proximal placement of electrodes are likely to have better speech recognition outcomes. Previous histological studies of humans demonstrated that speech recognition is correlated with spiral ganglion cell counts. Alternatively, ears with good speech recognition outcomes may have good overall neural health, which is a precondition for close electrodes to produce spatially confined neural excitation patterns that facilitate modulation sensitivity. These findings suggest that the methods to reduce channel interaction, e.g., perimodiolar electrode array or current focusing, may only be beneficial for a subgroup of CI users. Additionally, it suggests that estimating neural survival preoperatively is important for choosing the most appropriate electrode array type (perimodiolar vs. lateral wall) for optimal implant function. Elsevier 2022-12-22 /pmc/articles/PMC9958279/ /pubmed/36852047 http://dx.doi.org/10.1016/j.heliyon.2022.e12467 Text en © 2022 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Zhou, Ning
Shi, Xuyang
Dixit, Omkar
Firszt, Jill B.
Holden, Timothy A.
Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?
title Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?
title_full Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?
title_fullStr Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?
title_full_unstemmed Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?
title_short Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?
title_sort relationship between electrode position and temporal modulation sensitivity in cochlear implant users: are close electrodes always better?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958279/
https://www.ncbi.nlm.nih.gov/pubmed/36852047
http://dx.doi.org/10.1016/j.heliyon.2022.e12467
work_keys_str_mv AT zhouning relationshipbetweenelectrodepositionandtemporalmodulationsensitivityincochlearimplantusersarecloseelectrodesalwaysbetter
AT shixuyang relationshipbetweenelectrodepositionandtemporalmodulationsensitivityincochlearimplantusersarecloseelectrodesalwaysbetter
AT dixitomkar relationshipbetweenelectrodepositionandtemporalmodulationsensitivityincochlearimplantusersarecloseelectrodesalwaysbetter
AT firsztjillb relationshipbetweenelectrodepositionandtemporalmodulationsensitivityincochlearimplantusersarecloseelectrodesalwaysbetter
AT holdentimothya relationshipbetweenelectrodepositionandtemporalmodulationsensitivityincochlearimplantusersarecloseelectrodesalwaysbetter