Cargando…

Simultaneous assessment of heart and lungs with gated high-pitch ultra-low dose chest CT using artificial intelligence-based calcium scoring

PURPOSE: The combined testing for coronary artery and pulmonary diseases is of clinical interest as risk factors are shared. In this study, a novel ECG-gated tin-filtered ultra-low dose chest CT protocol (GCCT) for integrated heart and lung acquisition and the applicability of artificial intelligenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Andre, Florian, Seitz, Sebastian, Fortner, Philipp, Allmendinger, Thomas, Sommer, André, Brado, Matthias, Sokiranski, Roman, Fink, Joana, Kauczor, Hans-Ulrich, Heussel, Claus P., Herth, Felix, Frey, Norbert, Görich, Johannes, Buss, Sebastian J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9958356/
https://www.ncbi.nlm.nih.gov/pubmed/36852255
http://dx.doi.org/10.1016/j.ejro.2023.100481
Descripción
Sumario:PURPOSE: The combined testing for coronary artery and pulmonary diseases is of clinical interest as risk factors are shared. In this study, a novel ECG-gated tin-filtered ultra-low dose chest CT protocol (GCCT) for integrated heart and lung acquisition and the applicability of artificial intelligence (AI)-based coronary artery calcium scoring were assessed. METHODS: In a clinical registry of 10481 patients undergoing heart and lung CT, GCCT was applied in 44 patients on a dual-source CT. Coronary calcium scans (CCS) with 120 kVp, 100 kVp, and tin-filtered 100 kVp (Sn100) of controls, matched with regard to age, sex, and body-mass index, were retrieved from the registry (n(total)=176, 66.5 (59.4–74.0) years, 52 men). Automatic tube current modulation was used in all scans. In 20 patients undergoing GCCT and Sn100 CCS, Agatston scores were measured both semi-automatically by experts and by AI, and classified into six groups (0, <10, <100, <400, <1000, ≥1000). RESULTS: Effective dose decreased significantly from 120 kVp CCS (0.50 (0.41–0.61) mSv) to 100 kVp CCS (0.34 (0.26–0.37) mSv) to Sn100 CCS (0.14 (0.11–0.17) mSv). GCCT showed higher values (0.28 (0.21–0.32) mSv) than Sn100 CCS but lower than 120 kVp and 100 kVp CCS (all p < 0.05) despite greater scan length. Agatston scores correlated strongly between GCCT and Sn100 CCS in semi-automatic and AI-based measurements (both ρ = 0.98, p < 0.001) resulting in high agreement in Agatston score classification (κ = 0.97, 95% CI 0.92–1.00; κ = 0.89, 95% CI 0.79–0.99). Regarding chest findings, further diagnostic steps were recommended in 28 patients. CONCLUSIONS: GCCT allows for reliable coronary artery disease and lung cancer screening with ultra-low radiation exposure. GCCT-derived Agatston score shows excellent agreement with standard CCS, resulting in equivalent risk stratification.