Cargando…

Structural Performance of Infilled Steel–Concrete Composite Thin-Walled Columns Combined with FRP and CFRP: A Comprehensive Review

Fiber addition enhances the composite action between the steel tube and concrete core, increasing the strength of the concrete core. To better understand how fiber-reinforced infilled steel–concrete composite thin-walled columns (SCTWCs) behave, multiple investigations have been conducted using both...

Descripción completa

Detalles Bibliográficos
Autores principales: Rashid, S. M. Priok, Bahrami, Alireza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9959073/
https://www.ncbi.nlm.nih.gov/pubmed/36837197
http://dx.doi.org/10.3390/ma16041564
_version_ 1784895182871724032
author Rashid, S. M. Priok
Bahrami, Alireza
author_facet Rashid, S. M. Priok
Bahrami, Alireza
author_sort Rashid, S. M. Priok
collection PubMed
description Fiber addition enhances the composite action between the steel tube and concrete core, increasing the strength of the concrete core. To better understand how fiber-reinforced infilled steel–concrete composite thin-walled columns (SCTWCs) behave, multiple investigations have been conducted using both experimental and analytical methods. This article provides a comprehensive review of SCTWCs’ confinement approaches using fiber-reinforced polymer (FRP) and carbon fiber-reinforced polymer (CFRP). In this research, the behavior and formation of FRP and CFRP wrappings of the SCTWCs are reviewed and discussed. The ability of the FRP to serve as a confining material and reinforcement for the columns has increased its use in columns applications. The FRP can be applied to reinforce the structures from the exterior. By applying the CFRP strips, the columns’ load-carrying capacity is improved up to 30% when compared with their corresponding un-strengthened columns. External bonding of the CFRP strips efficiently creates external confinement pressure, prevents local buckling of the steel tubes, and enhances the load-carrying capacity of the SCTWCs. The primary goal is to facilitate a clear understanding of the SCTWCs. This article helps structural researchers and engineers better understand the behavior of the SCTWCs that include the FRP and CFRP composites as external reinforcement. Future research directions are also suggested, which utilize previous research works.
format Online
Article
Text
id pubmed-9959073
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99590732023-02-26 Structural Performance of Infilled Steel–Concrete Composite Thin-Walled Columns Combined with FRP and CFRP: A Comprehensive Review Rashid, S. M. Priok Bahrami, Alireza Materials (Basel) Review Fiber addition enhances the composite action between the steel tube and concrete core, increasing the strength of the concrete core. To better understand how fiber-reinforced infilled steel–concrete composite thin-walled columns (SCTWCs) behave, multiple investigations have been conducted using both experimental and analytical methods. This article provides a comprehensive review of SCTWCs’ confinement approaches using fiber-reinforced polymer (FRP) and carbon fiber-reinforced polymer (CFRP). In this research, the behavior and formation of FRP and CFRP wrappings of the SCTWCs are reviewed and discussed. The ability of the FRP to serve as a confining material and reinforcement for the columns has increased its use in columns applications. The FRP can be applied to reinforce the structures from the exterior. By applying the CFRP strips, the columns’ load-carrying capacity is improved up to 30% when compared with their corresponding un-strengthened columns. External bonding of the CFRP strips efficiently creates external confinement pressure, prevents local buckling of the steel tubes, and enhances the load-carrying capacity of the SCTWCs. The primary goal is to facilitate a clear understanding of the SCTWCs. This article helps structural researchers and engineers better understand the behavior of the SCTWCs that include the FRP and CFRP composites as external reinforcement. Future research directions are also suggested, which utilize previous research works. MDPI 2023-02-13 /pmc/articles/PMC9959073/ /pubmed/36837197 http://dx.doi.org/10.3390/ma16041564 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Rashid, S. M. Priok
Bahrami, Alireza
Structural Performance of Infilled Steel–Concrete Composite Thin-Walled Columns Combined with FRP and CFRP: A Comprehensive Review
title Structural Performance of Infilled Steel–Concrete Composite Thin-Walled Columns Combined with FRP and CFRP: A Comprehensive Review
title_full Structural Performance of Infilled Steel–Concrete Composite Thin-Walled Columns Combined with FRP and CFRP: A Comprehensive Review
title_fullStr Structural Performance of Infilled Steel–Concrete Composite Thin-Walled Columns Combined with FRP and CFRP: A Comprehensive Review
title_full_unstemmed Structural Performance of Infilled Steel–Concrete Composite Thin-Walled Columns Combined with FRP and CFRP: A Comprehensive Review
title_short Structural Performance of Infilled Steel–Concrete Composite Thin-Walled Columns Combined with FRP and CFRP: A Comprehensive Review
title_sort structural performance of infilled steel–concrete composite thin-walled columns combined with frp and cfrp: a comprehensive review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9959073/
https://www.ncbi.nlm.nih.gov/pubmed/36837197
http://dx.doi.org/10.3390/ma16041564
work_keys_str_mv AT rashidsmpriok structuralperformanceofinfilledsteelconcretecompositethinwalledcolumnscombinedwithfrpandcfrpacomprehensivereview
AT bahramialireza structuralperformanceofinfilledsteelconcretecompositethinwalledcolumnscombinedwithfrpandcfrpacomprehensivereview