Cargando…

Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates

Various testing methods and techniques have been used to identify and quantify per- and polyfluoroalkyl substances (PFAS) in food packaging. A common indirect measurement of PFAS is total fluorine (TF) and total organic fluorine (TOF). These methods are critical in rapidly screening food packaging m...

Descripción completa

Detalles Bibliográficos
Autores principales: Ignacio, Ma Cristine Concepcion D., Curtzwiler, Greg W., Early, Mark R., Updegraff, Katie M., Vorst, Keith L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9959142/
https://www.ncbi.nlm.nih.gov/pubmed/36827497
http://dx.doi.org/10.3390/mps6010010
_version_ 1784895200723730432
author Ignacio, Ma Cristine Concepcion D.
Curtzwiler, Greg W.
Early, Mark R.
Updegraff, Katie M.
Vorst, Keith L.
author_facet Ignacio, Ma Cristine Concepcion D.
Curtzwiler, Greg W.
Early, Mark R.
Updegraff, Katie M.
Vorst, Keith L.
author_sort Ignacio, Ma Cristine Concepcion D.
collection PubMed
description Various testing methods and techniques have been used to identify and quantify per- and polyfluoroalkyl substances (PFAS) in food packaging. A common indirect measurement of PFAS is total fluorine (TF) and total organic fluorine (TOF). These methods are critical in rapidly screening food packaging materials for the >9000 PFAS and are often globally used for regulatory limits. However, this destructive approach requires careful sample preparation, combustion, and the analysis of the solution by a fluoride-specific electrode. The method described herein is a cost-effective, rapid, quantitative, and externally validated initial screening of packaging materials for fluoro-chemistry. This study presents validated protocols for measuring TF and TOF in packaging substrates using oxygen combustion sample preparation coupled with fluoride ion-selective electrode (F-ISE); the materials and required equipment are provided, and the step-by-step procedure from sample preparation to the analysis are described, including critical steps to minimize contamination and interferences during sample preparation.
format Online
Article
Text
id pubmed-9959142
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99591422023-02-26 Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates Ignacio, Ma Cristine Concepcion D. Curtzwiler, Greg W. Early, Mark R. Updegraff, Katie M. Vorst, Keith L. Methods Protoc Protocol Various testing methods and techniques have been used to identify and quantify per- and polyfluoroalkyl substances (PFAS) in food packaging. A common indirect measurement of PFAS is total fluorine (TF) and total organic fluorine (TOF). These methods are critical in rapidly screening food packaging materials for the >9000 PFAS and are often globally used for regulatory limits. However, this destructive approach requires careful sample preparation, combustion, and the analysis of the solution by a fluoride-specific electrode. The method described herein is a cost-effective, rapid, quantitative, and externally validated initial screening of packaging materials for fluoro-chemistry. This study presents validated protocols for measuring TF and TOF in packaging substrates using oxygen combustion sample preparation coupled with fluoride ion-selective electrode (F-ISE); the materials and required equipment are provided, and the step-by-step procedure from sample preparation to the analysis are described, including critical steps to minimize contamination and interferences during sample preparation. MDPI 2023-01-18 /pmc/articles/PMC9959142/ /pubmed/36827497 http://dx.doi.org/10.3390/mps6010010 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Protocol
Ignacio, Ma Cristine Concepcion D.
Curtzwiler, Greg W.
Early, Mark R.
Updegraff, Katie M.
Vorst, Keith L.
Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates
title Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates
title_full Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates
title_fullStr Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates
title_full_unstemmed Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates
title_short Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates
title_sort ion selective electrode (ise) method for determination of total fluorine and total organic fluorine in packaging substrates
topic Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9959142/
https://www.ncbi.nlm.nih.gov/pubmed/36827497
http://dx.doi.org/10.3390/mps6010010
work_keys_str_mv AT ignaciomacristineconcepciond ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates
AT curtzwilergregw ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates
AT earlymarkr ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates
AT updegraffkatiem ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates
AT vorstkeithl ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates