Cargando…
Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates
Various testing methods and techniques have been used to identify and quantify per- and polyfluoroalkyl substances (PFAS) in food packaging. A common indirect measurement of PFAS is total fluorine (TF) and total organic fluorine (TOF). These methods are critical in rapidly screening food packaging m...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9959142/ https://www.ncbi.nlm.nih.gov/pubmed/36827497 http://dx.doi.org/10.3390/mps6010010 |
_version_ | 1784895200723730432 |
---|---|
author | Ignacio, Ma Cristine Concepcion D. Curtzwiler, Greg W. Early, Mark R. Updegraff, Katie M. Vorst, Keith L. |
author_facet | Ignacio, Ma Cristine Concepcion D. Curtzwiler, Greg W. Early, Mark R. Updegraff, Katie M. Vorst, Keith L. |
author_sort | Ignacio, Ma Cristine Concepcion D. |
collection | PubMed |
description | Various testing methods and techniques have been used to identify and quantify per- and polyfluoroalkyl substances (PFAS) in food packaging. A common indirect measurement of PFAS is total fluorine (TF) and total organic fluorine (TOF). These methods are critical in rapidly screening food packaging materials for the >9000 PFAS and are often globally used for regulatory limits. However, this destructive approach requires careful sample preparation, combustion, and the analysis of the solution by a fluoride-specific electrode. The method described herein is a cost-effective, rapid, quantitative, and externally validated initial screening of packaging materials for fluoro-chemistry. This study presents validated protocols for measuring TF and TOF in packaging substrates using oxygen combustion sample preparation coupled with fluoride ion-selective electrode (F-ISE); the materials and required equipment are provided, and the step-by-step procedure from sample preparation to the analysis are described, including critical steps to minimize contamination and interferences during sample preparation. |
format | Online Article Text |
id | pubmed-9959142 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99591422023-02-26 Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates Ignacio, Ma Cristine Concepcion D. Curtzwiler, Greg W. Early, Mark R. Updegraff, Katie M. Vorst, Keith L. Methods Protoc Protocol Various testing methods and techniques have been used to identify and quantify per- and polyfluoroalkyl substances (PFAS) in food packaging. A common indirect measurement of PFAS is total fluorine (TF) and total organic fluorine (TOF). These methods are critical in rapidly screening food packaging materials for the >9000 PFAS and are often globally used for regulatory limits. However, this destructive approach requires careful sample preparation, combustion, and the analysis of the solution by a fluoride-specific electrode. The method described herein is a cost-effective, rapid, quantitative, and externally validated initial screening of packaging materials for fluoro-chemistry. This study presents validated protocols for measuring TF and TOF in packaging substrates using oxygen combustion sample preparation coupled with fluoride ion-selective electrode (F-ISE); the materials and required equipment are provided, and the step-by-step procedure from sample preparation to the analysis are described, including critical steps to minimize contamination and interferences during sample preparation. MDPI 2023-01-18 /pmc/articles/PMC9959142/ /pubmed/36827497 http://dx.doi.org/10.3390/mps6010010 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Protocol Ignacio, Ma Cristine Concepcion D. Curtzwiler, Greg W. Early, Mark R. Updegraff, Katie M. Vorst, Keith L. Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates |
title | Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates |
title_full | Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates |
title_fullStr | Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates |
title_full_unstemmed | Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates |
title_short | Ion Selective Electrode (ISE) Method for Determination of Total Fluorine and Total Organic Fluorine in Packaging Substrates |
title_sort | ion selective electrode (ise) method for determination of total fluorine and total organic fluorine in packaging substrates |
topic | Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9959142/ https://www.ncbi.nlm.nih.gov/pubmed/36827497 http://dx.doi.org/10.3390/mps6010010 |
work_keys_str_mv | AT ignaciomacristineconcepciond ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates AT curtzwilergregw ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates AT earlymarkr ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates AT updegraffkatiem ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates AT vorstkeithl ionselectiveelectrodeisemethodfordeterminationoftotalfluorineandtotalorganicfluorineinpackagingsubstrates |