Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA)
In the present work, the microclimatic conditions (temperature (T), relative humidity (RH), and illuminance (I)), together with the air quality (both aerosol particulate matter (PM) and gaseous pollutants), were monitored to evaluate the environmental conditions inside the Santuario della Beata Verg...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9959446/ https://www.ncbi.nlm.nih.gov/pubmed/36838603 http://dx.doi.org/10.3390/molecules28041615 |
_version_ | 1784895278525972480 |
---|---|
author | Bergomi, Andrea Comite, Valeria Guglielmi, Vittoria Borelli, Mattia Lombardi, Chiara Andrea Bonomi, Roberto Pironti, Concetta Ricciardi, Maria Proto, Antonio Mariani, Carlo Fermo, Paola |
author_facet | Bergomi, Andrea Comite, Valeria Guglielmi, Vittoria Borelli, Mattia Lombardi, Chiara Andrea Bonomi, Roberto Pironti, Concetta Ricciardi, Maria Proto, Antonio Mariani, Carlo Fermo, Paola |
author_sort | Bergomi, Andrea |
collection | PubMed |
description | In the present work, the microclimatic conditions (temperature (T), relative humidity (RH), and illuminance (I)), together with the air quality (both aerosol particulate matter (PM) and gaseous pollutants), were monitored to evaluate the environmental conditions inside the Santuario della Beata Vergine dei Miracoli in Saronno (VA), a masterpiece of the Italian Renaissance. For this purpose, dataloggers were used to carry out the T, RH, and I measurements, whereas an optical particle counter (OPC) was employed to perform the particle count and determine the concentration of the aerosol PM. Finally, diffusive passive samplers were used to determine the concentration of nitrogen dioxide (NO(2)) and BTEX (benzene, toluene, ethylbenzene, and xylenes). To identify possible spatial variations, the studies were conducted at different sites and different heights in the Sanctuary. Particular focus was given to the Easter week during which liturgical services attracting large numbers of people were carried out. Additionally, a comparison with the outdoor values was performed to highlight the accumulation phenomena and other variations in the concentrations of the species. Despite the indoor concentrations of pollutants and variations in the thermohygrometric parameters being generally lower compared to the outdoors (e.g., 5.2–15.0 µg m(−3) versus 17.7–45.3 µg m(−3) for NO(2)), the microclimatic conditions were often not in line with the Italian legislation and technical standards. |
format | Online Article Text |
id | pubmed-9959446 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99594462023-02-26 Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA) Bergomi, Andrea Comite, Valeria Guglielmi, Vittoria Borelli, Mattia Lombardi, Chiara Andrea Bonomi, Roberto Pironti, Concetta Ricciardi, Maria Proto, Antonio Mariani, Carlo Fermo, Paola Molecules Article In the present work, the microclimatic conditions (temperature (T), relative humidity (RH), and illuminance (I)), together with the air quality (both aerosol particulate matter (PM) and gaseous pollutants), were monitored to evaluate the environmental conditions inside the Santuario della Beata Vergine dei Miracoli in Saronno (VA), a masterpiece of the Italian Renaissance. For this purpose, dataloggers were used to carry out the T, RH, and I measurements, whereas an optical particle counter (OPC) was employed to perform the particle count and determine the concentration of the aerosol PM. Finally, diffusive passive samplers were used to determine the concentration of nitrogen dioxide (NO(2)) and BTEX (benzene, toluene, ethylbenzene, and xylenes). To identify possible spatial variations, the studies were conducted at different sites and different heights in the Sanctuary. Particular focus was given to the Easter week during which liturgical services attracting large numbers of people were carried out. Additionally, a comparison with the outdoor values was performed to highlight the accumulation phenomena and other variations in the concentrations of the species. Despite the indoor concentrations of pollutants and variations in the thermohygrometric parameters being generally lower compared to the outdoors (e.g., 5.2–15.0 µg m(−3) versus 17.7–45.3 µg m(−3) for NO(2)), the microclimatic conditions were often not in line with the Italian legislation and technical standards. MDPI 2023-02-07 /pmc/articles/PMC9959446/ /pubmed/36838603 http://dx.doi.org/10.3390/molecules28041615 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bergomi, Andrea Comite, Valeria Guglielmi, Vittoria Borelli, Mattia Lombardi, Chiara Andrea Bonomi, Roberto Pironti, Concetta Ricciardi, Maria Proto, Antonio Mariani, Carlo Fermo, Paola Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA) |
title | Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA) |
title_full | Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA) |
title_fullStr | Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA) |
title_full_unstemmed | Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA) |
title_short | Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA) |
title_sort | preliminary air quality and microclimatic conditions study in the santuario della beata vergine dei miracoli in saronno (va) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9959446/ https://www.ncbi.nlm.nih.gov/pubmed/36838603 http://dx.doi.org/10.3390/molecules28041615 |
work_keys_str_mv | AT bergomiandrea preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT comitevaleria preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT guglielmivittoria preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT borellimattia preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT lombardichiaraandrea preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT bonomiroberto preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT pironticoncetta preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT ricciardimaria preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT protoantonio preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT marianicarlo preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova AT fermopaola preliminaryairqualityandmicroclimaticconditionsstudyinthesantuariodellabeataverginedeimiracoliinsaronnova |