Cargando…

Design and Testing of a Novel Nested, Compliant, Constant-Force Mechanism with Millimeter-Scale Strokes

This paper presents a novel nested, compliant, constant-force mechanism (CFM) that generates millimeter-scale manipulation stroke. The nested structure is utilized to improve the overall compactness of the CFM. A combination strategy of positive and negative stiffness is induced to generate constant...

Descripción completa

Detalles Bibliográficos
Autores principales: Qin, Xuejiao, Lu, Shuaishuai, Liu, Pengbo, Yan, Peng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9960792/
https://www.ncbi.nlm.nih.gov/pubmed/36838180
http://dx.doi.org/10.3390/mi14020480
_version_ 1784895595817730048
author Qin, Xuejiao
Lu, Shuaishuai
Liu, Pengbo
Yan, Peng
author_facet Qin, Xuejiao
Lu, Shuaishuai
Liu, Pengbo
Yan, Peng
author_sort Qin, Xuejiao
collection PubMed
description This paper presents a novel nested, compliant, constant-force mechanism (CFM) that generates millimeter-scale manipulation stroke. The nested structure is utilized to improve the overall compactness of the CFM. A combination strategy of positive and negative stiffness is induced to generate constant force with a millimeter-level range. In particular, bi-stable beams are used as the negative stiffness part, and V-shaped beams are selected as the positive stiffness part, and they are constructed into the nested structures. With this, a design concept of the CFM is first proposed. From this, an analytical model of the CFM was developed based on the pseudo-rigid body method (PRBM) and chain beam constraint model (CBCM), which was verified by conducting a simulation study with nonlinear finite-element analysis (FEA). Meanwhile, a parametric study was conducted to investigate the influence of the dominant design variable on the CFM performance. To demonstrate the performance of the CFM, a prototype was fabricated by wire cutting. The experimental results revealed that the proposed CFM owns a good constant-force property. This configuration of CFM provides new ideas for the design of millimeter-scale, constant-force, micro/nano, and hard-surface manipulation systems.
format Online
Article
Text
id pubmed-9960792
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99607922023-02-26 Design and Testing of a Novel Nested, Compliant, Constant-Force Mechanism with Millimeter-Scale Strokes Qin, Xuejiao Lu, Shuaishuai Liu, Pengbo Yan, Peng Micromachines (Basel) Article This paper presents a novel nested, compliant, constant-force mechanism (CFM) that generates millimeter-scale manipulation stroke. The nested structure is utilized to improve the overall compactness of the CFM. A combination strategy of positive and negative stiffness is induced to generate constant force with a millimeter-level range. In particular, bi-stable beams are used as the negative stiffness part, and V-shaped beams are selected as the positive stiffness part, and they are constructed into the nested structures. With this, a design concept of the CFM is first proposed. From this, an analytical model of the CFM was developed based on the pseudo-rigid body method (PRBM) and chain beam constraint model (CBCM), which was verified by conducting a simulation study with nonlinear finite-element analysis (FEA). Meanwhile, a parametric study was conducted to investigate the influence of the dominant design variable on the CFM performance. To demonstrate the performance of the CFM, a prototype was fabricated by wire cutting. The experimental results revealed that the proposed CFM owns a good constant-force property. This configuration of CFM provides new ideas for the design of millimeter-scale, constant-force, micro/nano, and hard-surface manipulation systems. MDPI 2023-02-18 /pmc/articles/PMC9960792/ /pubmed/36838180 http://dx.doi.org/10.3390/mi14020480 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Qin, Xuejiao
Lu, Shuaishuai
Liu, Pengbo
Yan, Peng
Design and Testing of a Novel Nested, Compliant, Constant-Force Mechanism with Millimeter-Scale Strokes
title Design and Testing of a Novel Nested, Compliant, Constant-Force Mechanism with Millimeter-Scale Strokes
title_full Design and Testing of a Novel Nested, Compliant, Constant-Force Mechanism with Millimeter-Scale Strokes
title_fullStr Design and Testing of a Novel Nested, Compliant, Constant-Force Mechanism with Millimeter-Scale Strokes
title_full_unstemmed Design and Testing of a Novel Nested, Compliant, Constant-Force Mechanism with Millimeter-Scale Strokes
title_short Design and Testing of a Novel Nested, Compliant, Constant-Force Mechanism with Millimeter-Scale Strokes
title_sort design and testing of a novel nested, compliant, constant-force mechanism with millimeter-scale strokes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9960792/
https://www.ncbi.nlm.nih.gov/pubmed/36838180
http://dx.doi.org/10.3390/mi14020480
work_keys_str_mv AT qinxuejiao designandtestingofanovelnestedcompliantconstantforcemechanismwithmillimeterscalestrokes
AT lushuaishuai designandtestingofanovelnestedcompliantconstantforcemechanismwithmillimeterscalestrokes
AT liupengbo designandtestingofanovelnestedcompliantconstantforcemechanismwithmillimeterscalestrokes
AT yanpeng designandtestingofanovelnestedcompliantconstantforcemechanismwithmillimeterscalestrokes