Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement
The ability to generate force in the lower body can be considered a performance factor in sports. This study aims to analyze the test–retest and between-device reliability related to the location on the body of the inertial measurement unit Vmaxpro for the estimation of vertical jump. Eleven highly...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9960825/ https://www.ncbi.nlm.nih.gov/pubmed/36850666 http://dx.doi.org/10.3390/s23042068 |
_version_ | 1784895603878133760 |
---|---|
author | Villalon-Gasch, Lamberto Jimenez-Olmedo, Jose M. Olaya-Cuartero, Javier Pueo, Basilio |
author_facet | Villalon-Gasch, Lamberto Jimenez-Olmedo, Jose M. Olaya-Cuartero, Javier Pueo, Basilio |
author_sort | Villalon-Gasch, Lamberto |
collection | PubMed |
description | The ability to generate force in the lower body can be considered a performance factor in sports. This study aims to analyze the test–retest and between-device reliability related to the location on the body of the inertial measurement unit Vmaxpro for the estimation of vertical jump. Eleven highly trained female athletes performed 220 countermovement jumps (CMJ). Data were simultaneously captured by two Vmaxpro units located between L4 and L5 vertebrae (hip method) and on top of the tibial malleolus (ankle method). Intrasession reliability was higher for ankle (ICC = 0.96; CCC = 0.93; SEM = 1.0 cm; CV = 4.64%) than hip (ICC = 0.91; CCC = 0.92; SEM = 3.4 cm; CV = 5.13%). In addition, sensitivity was higher for ankle (SWC = 0.28) than for the hip method (SWC = 0.40). The noise of the measurement (SEM) was higher than the worthwhile change (SWC), indicating lack of ability to detect meaningful changes. The agreement between methods was moderate (r(s) = 0.84; ICC = 0.77; CCC = 0.25; SEM = 1.47 cm). Significant differences were detected between methods (−8.5 cm, p < 0.05, ES = 2.2). In conclusion, the location of the device affects the measurement by underestimating CMJ on ankle. Despite the acceptable consistency of the instrument, the results of the reliability analysis reveal a significant magnitude of both random and systematic error. As such, the Vmaxpro should not be considered a reliable instrument for measuring CMJ. |
format | Online Article Text |
id | pubmed-9960825 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99608252023-02-26 Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement Villalon-Gasch, Lamberto Jimenez-Olmedo, Jose M. Olaya-Cuartero, Javier Pueo, Basilio Sensors (Basel) Article The ability to generate force in the lower body can be considered a performance factor in sports. This study aims to analyze the test–retest and between-device reliability related to the location on the body of the inertial measurement unit Vmaxpro for the estimation of vertical jump. Eleven highly trained female athletes performed 220 countermovement jumps (CMJ). Data were simultaneously captured by two Vmaxpro units located between L4 and L5 vertebrae (hip method) and on top of the tibial malleolus (ankle method). Intrasession reliability was higher for ankle (ICC = 0.96; CCC = 0.93; SEM = 1.0 cm; CV = 4.64%) than hip (ICC = 0.91; CCC = 0.92; SEM = 3.4 cm; CV = 5.13%). In addition, sensitivity was higher for ankle (SWC = 0.28) than for the hip method (SWC = 0.40). The noise of the measurement (SEM) was higher than the worthwhile change (SWC), indicating lack of ability to detect meaningful changes. The agreement between methods was moderate (r(s) = 0.84; ICC = 0.77; CCC = 0.25; SEM = 1.47 cm). Significant differences were detected between methods (−8.5 cm, p < 0.05, ES = 2.2). In conclusion, the location of the device affects the measurement by underestimating CMJ on ankle. Despite the acceptable consistency of the instrument, the results of the reliability analysis reveal a significant magnitude of both random and systematic error. As such, the Vmaxpro should not be considered a reliable instrument for measuring CMJ. MDPI 2023-02-12 /pmc/articles/PMC9960825/ /pubmed/36850666 http://dx.doi.org/10.3390/s23042068 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Villalon-Gasch, Lamberto Jimenez-Olmedo, Jose M. Olaya-Cuartero, Javier Pueo, Basilio Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement |
title | Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement |
title_full | Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement |
title_fullStr | Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement |
title_full_unstemmed | Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement |
title_short | Test–Retest and Between–Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement |
title_sort | test–retest and between–device reliability of vmaxpro imu at hip and ankle for vertical jump measurement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9960825/ https://www.ncbi.nlm.nih.gov/pubmed/36850666 http://dx.doi.org/10.3390/s23042068 |
work_keys_str_mv | AT villalongaschlamberto testretestandbetweendevicereliabilityofvmaxproimuathipandankleforverticaljumpmeasurement AT jimenezolmedojosem testretestandbetweendevicereliabilityofvmaxproimuathipandankleforverticaljumpmeasurement AT olayacuarterojavier testretestandbetweendevicereliabilityofvmaxproimuathipandankleforverticaljumpmeasurement AT pueobasilio testretestandbetweendevicereliabilityofvmaxproimuathipandankleforverticaljumpmeasurement |