Cargando…

Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study

Purpose: To propose a novel, radiation-free method for postoperative three-dimensional (3D) position analysis of dental implants based on the dynamic navigation system (DNS) and evaluate its accuracy in vitro. Methods: A total of 60 implants were digitally planned and then placed in the standardized...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Feifei, Liu, Mingyue, Liu, Xiaoqiang, Wei, Tai, Liu, Lilan, Sun, Feng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9960986/
https://www.ncbi.nlm.nih.gov/pubmed/36836596
http://dx.doi.org/10.3390/jpm13020362
_version_ 1784895643865579520
author Ma, Feifei
Liu, Mingyue
Liu, Xiaoqiang
Wei, Tai
Liu, Lilan
Sun, Feng
author_facet Ma, Feifei
Liu, Mingyue
Liu, Xiaoqiang
Wei, Tai
Liu, Lilan
Sun, Feng
author_sort Ma, Feifei
collection PubMed
description Purpose: To propose a novel, radiation-free method for postoperative three-dimensional (3D) position analysis of dental implants based on the dynamic navigation system (DNS) and evaluate its accuracy in vitro. Methods: A total of 60 implants were digitally planned and then placed in the standardized plastic models with a single-tooth gap and a free-end gap under the guidance of the DNS. Postoperative 3D positions of the inserted implants were evaluated using specially designed navigation-based software, and its datasets were superimposed onto those of cone beam computed tomography (CBCT) for accuracy analyses. Deviations at the coronal, apical, and angular levels were measured and statistically analyzed. Results: The mean 3D deviation was 0.88 ± 0.37 mm at the entry point and 1.02 ± 0.35 mm at the apex point. The mean angular deviation was 1.83 ± 0.79 degrees. No significant differences were noted in the deviations between implants placed in the single-tooth gap and the free-end situation (p > 0.05) or between different tooth positions at distal extensions (p > 0.05). Conclusions: This non-radiographic method provides facile, efficient, and reliable postoperative implant position evaluation and may be a potential substitute for CBCT, particularly for implants placed under the guidance of dynamic navigation.
format Online
Article
Text
id pubmed-9960986
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99609862023-02-26 Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study Ma, Feifei Liu, Mingyue Liu, Xiaoqiang Wei, Tai Liu, Lilan Sun, Feng J Pers Med Article Purpose: To propose a novel, radiation-free method for postoperative three-dimensional (3D) position analysis of dental implants based on the dynamic navigation system (DNS) and evaluate its accuracy in vitro. Methods: A total of 60 implants were digitally planned and then placed in the standardized plastic models with a single-tooth gap and a free-end gap under the guidance of the DNS. Postoperative 3D positions of the inserted implants were evaluated using specially designed navigation-based software, and its datasets were superimposed onto those of cone beam computed tomography (CBCT) for accuracy analyses. Deviations at the coronal, apical, and angular levels were measured and statistically analyzed. Results: The mean 3D deviation was 0.88 ± 0.37 mm at the entry point and 1.02 ± 0.35 mm at the apex point. The mean angular deviation was 1.83 ± 0.79 degrees. No significant differences were noted in the deviations between implants placed in the single-tooth gap and the free-end situation (p > 0.05) or between different tooth positions at distal extensions (p > 0.05). Conclusions: This non-radiographic method provides facile, efficient, and reliable postoperative implant position evaluation and may be a potential substitute for CBCT, particularly for implants placed under the guidance of dynamic navigation. MDPI 2023-02-18 /pmc/articles/PMC9960986/ /pubmed/36836596 http://dx.doi.org/10.3390/jpm13020362 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ma, Feifei
Liu, Mingyue
Liu, Xiaoqiang
Wei, Tai
Liu, Lilan
Sun, Feng
Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study
title Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study
title_full Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study
title_fullStr Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study
title_full_unstemmed Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study
title_short Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study
title_sort proposal and validation of a new nonradiological method for postoperative three-dimensional implant position analysis based on the dynamic navigation system: an in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9960986/
https://www.ncbi.nlm.nih.gov/pubmed/36836596
http://dx.doi.org/10.3390/jpm13020362
work_keys_str_mv AT mafeifei proposalandvalidationofanewnonradiologicalmethodforpostoperativethreedimensionalimplantpositionanalysisbasedonthedynamicnavigationsystemaninvitrostudy
AT liumingyue proposalandvalidationofanewnonradiologicalmethodforpostoperativethreedimensionalimplantpositionanalysisbasedonthedynamicnavigationsystemaninvitrostudy
AT liuxiaoqiang proposalandvalidationofanewnonradiologicalmethodforpostoperativethreedimensionalimplantpositionanalysisbasedonthedynamicnavigationsystemaninvitrostudy
AT weitai proposalandvalidationofanewnonradiologicalmethodforpostoperativethreedimensionalimplantpositionanalysisbasedonthedynamicnavigationsystemaninvitrostudy
AT liulilan proposalandvalidationofanewnonradiologicalmethodforpostoperativethreedimensionalimplantpositionanalysisbasedonthedynamicnavigationsystemaninvitrostudy
AT sunfeng proposalandvalidationofanewnonradiologicalmethodforpostoperativethreedimensionalimplantpositionanalysisbasedonthedynamicnavigationsystemaninvitrostudy