Cargando…
Non-Contact, Continuous Sampling of Porous Surfaces for the Detection of Particulate and Adsorbed Organic Contaminations by Low-Temperature Plasma Coupled to Ion Mobility Spectrometer
Chemical analysis of hazardous surface contaminations, such as hazardous substances, explosives or illicit drugs, is an essential task in security, environmental and safety applications. This task is mostly based on the collection of particles with swabs, followed by thermal desorption into a vapor...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9961393/ https://www.ncbi.nlm.nih.gov/pubmed/36850851 http://dx.doi.org/10.3390/s23042253 |
_version_ | 1784895743395364864 |
---|---|
author | Ron, Izhar Sharabi, Hagay Zaltsman, Amalia Leibman, Amir Hotoveli, Mordi Pevzner, Alexander Kendler, Shai |
author_facet | Ron, Izhar Sharabi, Hagay Zaltsman, Amalia Leibman, Amir Hotoveli, Mordi Pevzner, Alexander Kendler, Shai |
author_sort | Ron, Izhar |
collection | PubMed |
description | Chemical analysis of hazardous surface contaminations, such as hazardous substances, explosives or illicit drugs, is an essential task in security, environmental and safety applications. This task is mostly based on the collection of particles with swabs, followed by thermal desorption into a vapor analyzer, usually a detector based on ion mobility spectrometry (IMS). While this methodology is well established for several civil applications, such as border control, it is still not efficient enough for various conditions, as in sampling rough and porous surfaces. Additionally, the process of thermal desorption is energetically inefficient, requires bulky hardware and introduces device contamination memory effects. Low-temperature plasma (LTP) has been demonstrated as an ionization and desorption source for sample preparation-free analysis, mostly at the inlet of a mass spectrometer analyzer, and in rare cases in conjunction with an ion mobility spectrometer. Herein, we demonstrate, for the first time, the operation of a simple, low cost, home-built LTP apparatus for desorbing non-volatile analytes from various porous surfaces into the inlet of a handheld IMS vapor analyzer. We show ion mobility spectra that originate from operating the LTP jet on porous surfaces such as asphalt and shoes, contaminated with model amine-containing organic compounds. The spectra are in good correlation with spectra measured for thermally desorbed species. We verify through LC-MS analysis of the collected vapors that the sampled species are not fragmented, and can thus be identified by commercial IMS detectors. |
format | Online Article Text |
id | pubmed-9961393 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99613932023-02-26 Non-Contact, Continuous Sampling of Porous Surfaces for the Detection of Particulate and Adsorbed Organic Contaminations by Low-Temperature Plasma Coupled to Ion Mobility Spectrometer Ron, Izhar Sharabi, Hagay Zaltsman, Amalia Leibman, Amir Hotoveli, Mordi Pevzner, Alexander Kendler, Shai Sensors (Basel) Article Chemical analysis of hazardous surface contaminations, such as hazardous substances, explosives or illicit drugs, is an essential task in security, environmental and safety applications. This task is mostly based on the collection of particles with swabs, followed by thermal desorption into a vapor analyzer, usually a detector based on ion mobility spectrometry (IMS). While this methodology is well established for several civil applications, such as border control, it is still not efficient enough for various conditions, as in sampling rough and porous surfaces. Additionally, the process of thermal desorption is energetically inefficient, requires bulky hardware and introduces device contamination memory effects. Low-temperature plasma (LTP) has been demonstrated as an ionization and desorption source for sample preparation-free analysis, mostly at the inlet of a mass spectrometer analyzer, and in rare cases in conjunction with an ion mobility spectrometer. Herein, we demonstrate, for the first time, the operation of a simple, low cost, home-built LTP apparatus for desorbing non-volatile analytes from various porous surfaces into the inlet of a handheld IMS vapor analyzer. We show ion mobility spectra that originate from operating the LTP jet on porous surfaces such as asphalt and shoes, contaminated with model amine-containing organic compounds. The spectra are in good correlation with spectra measured for thermally desorbed species. We verify through LC-MS analysis of the collected vapors that the sampled species are not fragmented, and can thus be identified by commercial IMS detectors. MDPI 2023-02-17 /pmc/articles/PMC9961393/ /pubmed/36850851 http://dx.doi.org/10.3390/s23042253 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ron, Izhar Sharabi, Hagay Zaltsman, Amalia Leibman, Amir Hotoveli, Mordi Pevzner, Alexander Kendler, Shai Non-Contact, Continuous Sampling of Porous Surfaces for the Detection of Particulate and Adsorbed Organic Contaminations by Low-Temperature Plasma Coupled to Ion Mobility Spectrometer |
title | Non-Contact, Continuous Sampling of Porous Surfaces for the Detection of Particulate and Adsorbed Organic Contaminations by Low-Temperature Plasma Coupled to Ion Mobility Spectrometer |
title_full | Non-Contact, Continuous Sampling of Porous Surfaces for the Detection of Particulate and Adsorbed Organic Contaminations by Low-Temperature Plasma Coupled to Ion Mobility Spectrometer |
title_fullStr | Non-Contact, Continuous Sampling of Porous Surfaces for the Detection of Particulate and Adsorbed Organic Contaminations by Low-Temperature Plasma Coupled to Ion Mobility Spectrometer |
title_full_unstemmed | Non-Contact, Continuous Sampling of Porous Surfaces for the Detection of Particulate and Adsorbed Organic Contaminations by Low-Temperature Plasma Coupled to Ion Mobility Spectrometer |
title_short | Non-Contact, Continuous Sampling of Porous Surfaces for the Detection of Particulate and Adsorbed Organic Contaminations by Low-Temperature Plasma Coupled to Ion Mobility Spectrometer |
title_sort | non-contact, continuous sampling of porous surfaces for the detection of particulate and adsorbed organic contaminations by low-temperature plasma coupled to ion mobility spectrometer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9961393/ https://www.ncbi.nlm.nih.gov/pubmed/36850851 http://dx.doi.org/10.3390/s23042253 |
work_keys_str_mv | AT ronizhar noncontactcontinuoussamplingofporoussurfacesforthedetectionofparticulateandadsorbedorganiccontaminationsbylowtemperatureplasmacoupledtoionmobilityspectrometer AT sharabihagay noncontactcontinuoussamplingofporoussurfacesforthedetectionofparticulateandadsorbedorganiccontaminationsbylowtemperatureplasmacoupledtoionmobilityspectrometer AT zaltsmanamalia noncontactcontinuoussamplingofporoussurfacesforthedetectionofparticulateandadsorbedorganiccontaminationsbylowtemperatureplasmacoupledtoionmobilityspectrometer AT leibmanamir noncontactcontinuoussamplingofporoussurfacesforthedetectionofparticulateandadsorbedorganiccontaminationsbylowtemperatureplasmacoupledtoionmobilityspectrometer AT hotovelimordi noncontactcontinuoussamplingofporoussurfacesforthedetectionofparticulateandadsorbedorganiccontaminationsbylowtemperatureplasmacoupledtoionmobilityspectrometer AT pevzneralexander noncontactcontinuoussamplingofporoussurfacesforthedetectionofparticulateandadsorbedorganiccontaminationsbylowtemperatureplasmacoupledtoionmobilityspectrometer AT kendlershai noncontactcontinuoussamplingofporoussurfacesforthedetectionofparticulateandadsorbedorganiccontaminationsbylowtemperatureplasmacoupledtoionmobilityspectrometer |