Numerical Study on Thermal Stress of High Temperature Proton Exchange Membrane Fuel Cells during Start-Up Process
High-temperature proton-exchange membrane fuel cells (HT-PEMFCs) with phosphoric-doped polybenzimidazole (PBI) membranes have a higher operating temperature compared to the PEMFCs operating below 373.15 K. The fuel cell is first heated from room temperature to the minimum operating temperature to av...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963054/ https://www.ncbi.nlm.nih.gov/pubmed/36837718 http://dx.doi.org/10.3390/membranes13020215 |
_version_ | 1784896156282650624 |
---|---|
author | Li, Shian Peng, Chengdong Shen, Qiuwan Cheng, Yuanzhe Wang, Chongyang Yang, Guogang |
author_facet | Li, Shian Peng, Chengdong Shen, Qiuwan Cheng, Yuanzhe Wang, Chongyang Yang, Guogang |
author_sort | Li, Shian |
collection | PubMed |
description | High-temperature proton-exchange membrane fuel cells (HT-PEMFCs) with phosphoric-doped polybenzimidazole (PBI) membranes have a higher operating temperature compared to the PEMFCs operating below 373.15 K. The fuel cell is first heated from room temperature to the minimum operating temperature to avoid the generation of liquid water. The existence of liquid water can result in the loss of phosphoric acid and then affect the cell performance. In this study, the start-up process of HT-PEMFCs is numerically studied by establishing a three-dimensional non-isothermal mathematical model. Preheated gas is supplied into gas flow channels to heat the fuel cell, and then voltage load is applied to accelerate the start-up process. Effects of voltage (0.9 V, 0.7 V and 0.5 V) and flow arrangement (co-flow and counter flow) on temperature, current density, proton conductivity and stress distributions of fuel cells are examined. It is found that the maximum stress is increased when a lower voltage is adopted, and the counter-flow arrangement provides a more uniform stress distribution than that of co-flow arrangement. |
format | Online Article Text |
id | pubmed-9963054 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99630542023-02-26 Numerical Study on Thermal Stress of High Temperature Proton Exchange Membrane Fuel Cells during Start-Up Process Li, Shian Peng, Chengdong Shen, Qiuwan Cheng, Yuanzhe Wang, Chongyang Yang, Guogang Membranes (Basel) Article High-temperature proton-exchange membrane fuel cells (HT-PEMFCs) with phosphoric-doped polybenzimidazole (PBI) membranes have a higher operating temperature compared to the PEMFCs operating below 373.15 K. The fuel cell is first heated from room temperature to the minimum operating temperature to avoid the generation of liquid water. The existence of liquid water can result in the loss of phosphoric acid and then affect the cell performance. In this study, the start-up process of HT-PEMFCs is numerically studied by establishing a three-dimensional non-isothermal mathematical model. Preheated gas is supplied into gas flow channels to heat the fuel cell, and then voltage load is applied to accelerate the start-up process. Effects of voltage (0.9 V, 0.7 V and 0.5 V) and flow arrangement (co-flow and counter flow) on temperature, current density, proton conductivity and stress distributions of fuel cells are examined. It is found that the maximum stress is increased when a lower voltage is adopted, and the counter-flow arrangement provides a more uniform stress distribution than that of co-flow arrangement. MDPI 2023-02-09 /pmc/articles/PMC9963054/ /pubmed/36837718 http://dx.doi.org/10.3390/membranes13020215 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Shian Peng, Chengdong Shen, Qiuwan Cheng, Yuanzhe Wang, Chongyang Yang, Guogang Numerical Study on Thermal Stress of High Temperature Proton Exchange Membrane Fuel Cells during Start-Up Process |
title | Numerical Study on Thermal Stress of High Temperature Proton Exchange Membrane Fuel Cells during Start-Up Process |
title_full | Numerical Study on Thermal Stress of High Temperature Proton Exchange Membrane Fuel Cells during Start-Up Process |
title_fullStr | Numerical Study on Thermal Stress of High Temperature Proton Exchange Membrane Fuel Cells during Start-Up Process |
title_full_unstemmed | Numerical Study on Thermal Stress of High Temperature Proton Exchange Membrane Fuel Cells during Start-Up Process |
title_short | Numerical Study on Thermal Stress of High Temperature Proton Exchange Membrane Fuel Cells during Start-Up Process |
title_sort | numerical study on thermal stress of high temperature proton exchange membrane fuel cells during start-up process |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963054/ https://www.ncbi.nlm.nih.gov/pubmed/36837718 http://dx.doi.org/10.3390/membranes13020215 |
work_keys_str_mv | AT lishian numericalstudyonthermalstressofhightemperatureprotonexchangemembranefuelcellsduringstartupprocess AT pengchengdong numericalstudyonthermalstressofhightemperatureprotonexchangemembranefuelcellsduringstartupprocess AT shenqiuwan numericalstudyonthermalstressofhightemperatureprotonexchangemembranefuelcellsduringstartupprocess AT chengyuanzhe numericalstudyonthermalstressofhightemperatureprotonexchangemembranefuelcellsduringstartupprocess AT wangchongyang numericalstudyonthermalstressofhightemperatureprotonexchangemembranefuelcellsduringstartupprocess AT yangguogang numericalstudyonthermalstressofhightemperatureprotonexchangemembranefuelcellsduringstartupprocess |