Cargando…
Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions
Purpose, Retrograde recanalizations have gained increasing recognition in complex arterial occlusive disease. Re-entry devices are a well described adjunct for antegrade recanalizations. We present our experience with target balloon-assisted antegrade and retrograde recanalizations using re-entry de...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963594/ https://www.ncbi.nlm.nih.gov/pubmed/36826548 http://dx.doi.org/10.3390/jcdd10020053 |
_version_ | 1784896290395521024 |
---|---|
author | Patrone, Lorenzo Theivacumar, Nada Selva Dharmarajah, Brahman Thulasidasan, Narayanan Diamantopoulos, Athanasios Palena, Luis Mariano Antaredja, Muliadi Tilemann, Lisa Blessing, Erwin |
author_facet | Patrone, Lorenzo Theivacumar, Nada Selva Dharmarajah, Brahman Thulasidasan, Narayanan Diamantopoulos, Athanasios Palena, Luis Mariano Antaredja, Muliadi Tilemann, Lisa Blessing, Erwin |
author_sort | Patrone, Lorenzo |
collection | PubMed |
description | Purpose, Retrograde recanalizations have gained increasing recognition in complex arterial occlusive disease. Re-entry devices are a well described adjunct for antegrade recanalizations. We present our experience with target balloon-assisted antegrade and retrograde recanalizations using re-entry devices in challenging chronic total occlusions. Materials and Methods: We report data from a retrospective multicenter registry. Eligibility criteria included either antegrade or retrograde use of the Outback(TM) or GoBack(TM) re-entry catheter in combination with a balloon as a target to accomplish wire passage, when conventional antegrade and retrograde recanalization attempts had been unsuccessful. Procedural outcomes included technical success (defined as wire passage though the occlusion and delivery of adjunctive therapy with <30% residual stenosis at final angiogram), safety (periprocedural complications, e.g., bleeding, vessel injury, or occlusion of the artery at the re-entry site, and distal embolizations), and clinical outcome (amputation-free survival and freedom from target lesion revascularization after 12-months follow-up). Results: Thirty-six consecutive patients underwent target balloon-assisted recanalization attempts. Fourteen (39 %) patients had a history of open vascular surgery in the index limb. Fifteen patients were claudications (Rutherford Class 2 or 3, 21 presented with chronic limb threatening limb ischemia (Rutherford Class 4 to 6). The locations of the occlusive lesions were as follows: iliac arteries in 3 cases, femoropopliteal artery in 39 cases, and in below-the-knee arteries in 12 cases. In 15 cases, recanalization was attempted in multilevel occlusions. Retrograde access was attempted in 1 case in the common femoral artery, in the femoropopliteal segment in 10 cases, in below-the-knee arteries in 23 cases, and finally in 2 patients via the brachial artery. In 10 cases, the re-entry devices were inserted via the retrograde access site. Technical success was achieved in 34 (94 %) patients. There were 3 periprocedural complications, none directly related to the target balloon-assisted re-entry maneuver. Amputation-free survival was 87.8 % and freedom from clinically driven target lesion revascularization was 86.6 % after 12-months follow-up. Conclusion: Target balloon-assisted use of re-entry devices in chronic total occlusions provides an effective and safe endovascular adjunct, when conventional antegrade and retrograde recanalization attempts have failed. |
format | Online Article Text |
id | pubmed-9963594 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99635942023-02-26 Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions Patrone, Lorenzo Theivacumar, Nada Selva Dharmarajah, Brahman Thulasidasan, Narayanan Diamantopoulos, Athanasios Palena, Luis Mariano Antaredja, Muliadi Tilemann, Lisa Blessing, Erwin J Cardiovasc Dev Dis Article Purpose, Retrograde recanalizations have gained increasing recognition in complex arterial occlusive disease. Re-entry devices are a well described adjunct for antegrade recanalizations. We present our experience with target balloon-assisted antegrade and retrograde recanalizations using re-entry devices in challenging chronic total occlusions. Materials and Methods: We report data from a retrospective multicenter registry. Eligibility criteria included either antegrade or retrograde use of the Outback(TM) or GoBack(TM) re-entry catheter in combination with a balloon as a target to accomplish wire passage, when conventional antegrade and retrograde recanalization attempts had been unsuccessful. Procedural outcomes included technical success (defined as wire passage though the occlusion and delivery of adjunctive therapy with <30% residual stenosis at final angiogram), safety (periprocedural complications, e.g., bleeding, vessel injury, or occlusion of the artery at the re-entry site, and distal embolizations), and clinical outcome (amputation-free survival and freedom from target lesion revascularization after 12-months follow-up). Results: Thirty-six consecutive patients underwent target balloon-assisted recanalization attempts. Fourteen (39 %) patients had a history of open vascular surgery in the index limb. Fifteen patients were claudications (Rutherford Class 2 or 3, 21 presented with chronic limb threatening limb ischemia (Rutherford Class 4 to 6). The locations of the occlusive lesions were as follows: iliac arteries in 3 cases, femoropopliteal artery in 39 cases, and in below-the-knee arteries in 12 cases. In 15 cases, recanalization was attempted in multilevel occlusions. Retrograde access was attempted in 1 case in the common femoral artery, in the femoropopliteal segment in 10 cases, in below-the-knee arteries in 23 cases, and finally in 2 patients via the brachial artery. In 10 cases, the re-entry devices were inserted via the retrograde access site. Technical success was achieved in 34 (94 %) patients. There were 3 periprocedural complications, none directly related to the target balloon-assisted re-entry maneuver. Amputation-free survival was 87.8 % and freedom from clinically driven target lesion revascularization was 86.6 % after 12-months follow-up. Conclusion: Target balloon-assisted use of re-entry devices in chronic total occlusions provides an effective and safe endovascular adjunct, when conventional antegrade and retrograde recanalization attempts have failed. MDPI 2023-01-29 /pmc/articles/PMC9963594/ /pubmed/36826548 http://dx.doi.org/10.3390/jcdd10020053 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Patrone, Lorenzo Theivacumar, Nada Selva Dharmarajah, Brahman Thulasidasan, Narayanan Diamantopoulos, Athanasios Palena, Luis Mariano Antaredja, Muliadi Tilemann, Lisa Blessing, Erwin Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions |
title | Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions |
title_full | Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions |
title_fullStr | Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions |
title_full_unstemmed | Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions |
title_short | Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions |
title_sort | target balloon-assisted antegrade and retrograde use of re-entry catheters in complex chronic total occlusions |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963594/ https://www.ncbi.nlm.nih.gov/pubmed/36826548 http://dx.doi.org/10.3390/jcdd10020053 |
work_keys_str_mv | AT patronelorenzo targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions AT theivacumarnadaselva targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions AT dharmarajahbrahman targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions AT thulasidasannarayanan targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions AT diamantopoulosathanasios targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions AT palenaluismariano targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions AT antaredjamuliadi targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions AT tilemannlisa targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions AT blessingerwin targetballoonassistedantegradeandretrogradeuseofreentrycathetersincomplexchronictotalocclusions |