Cargando…
Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot
Minimally invasive surgical robots have the advantages of high positioning accuracy, good stability, and flexible operation, which can effectively improve the quality of surgery and reduce the difficulty for doctors to operate. However, in order to realize the translation of the existing RCM mechani...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963641/ https://www.ncbi.nlm.nih.gov/pubmed/36850959 http://dx.doi.org/10.3390/s23042361 |
_version_ | 1784896303046590464 |
---|---|
author | Shi, Hu Liang, Zhixin Zhang, Boyang Wang, Haitao |
author_facet | Shi, Hu Liang, Zhixin Zhang, Boyang Wang, Haitao |
author_sort | Shi, Hu |
collection | PubMed |
description | Minimally invasive surgical robots have the advantages of high positioning accuracy, good stability, and flexible operation, which can effectively improve the quality of surgery and reduce the difficulty for doctors to operate. However, in order to realize the translation of the existing RCM mechanism, it is often necessary to add a mobile unit, which is often bulky and occupies most space above the patient’s body, thus causing interference to the operation. In this paper, a new type of planar RCM mechanism is proposed. Based on this mechanism, a 3-DOF robotic arm is designed, which can complete the required motion for surgery without adding a mobile unit. In this paper, the geometric model of the mechanism is first introduced, and the RCM point of the mechanism is proven during the motion process. Then, based on the establishment of the geometric model of the mechanism, a kinematics analysis of the mechanism is carried out. The singularity, the Jacobian matrix, and the kinematic performance of the mechanism are analyzed, and the working space of the mechanism is verified according to the kinematic equations. Finally, a prototype of the RCM mechanism was built, and its functionality was tested using a master–slave control strategy. |
format | Online Article Text |
id | pubmed-9963641 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99636412023-02-26 Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot Shi, Hu Liang, Zhixin Zhang, Boyang Wang, Haitao Sensors (Basel) Article Minimally invasive surgical robots have the advantages of high positioning accuracy, good stability, and flexible operation, which can effectively improve the quality of surgery and reduce the difficulty for doctors to operate. However, in order to realize the translation of the existing RCM mechanism, it is often necessary to add a mobile unit, which is often bulky and occupies most space above the patient’s body, thus causing interference to the operation. In this paper, a new type of planar RCM mechanism is proposed. Based on this mechanism, a 3-DOF robotic arm is designed, which can complete the required motion for surgery without adding a mobile unit. In this paper, the geometric model of the mechanism is first introduced, and the RCM point of the mechanism is proven during the motion process. Then, based on the establishment of the geometric model of the mechanism, a kinematics analysis of the mechanism is carried out. The singularity, the Jacobian matrix, and the kinematic performance of the mechanism are analyzed, and the working space of the mechanism is verified according to the kinematic equations. Finally, a prototype of the RCM mechanism was built, and its functionality was tested using a master–slave control strategy. MDPI 2023-02-20 /pmc/articles/PMC9963641/ /pubmed/36850959 http://dx.doi.org/10.3390/s23042361 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shi, Hu Liang, Zhixin Zhang, Boyang Wang, Haitao Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot |
title | Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot |
title_full | Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot |
title_fullStr | Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot |
title_full_unstemmed | Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot |
title_short | Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot |
title_sort | design and performance verification of a novel rcm mechanism for a minimally invasive surgical robot |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963641/ https://www.ncbi.nlm.nih.gov/pubmed/36850959 http://dx.doi.org/10.3390/s23042361 |
work_keys_str_mv | AT shihu designandperformanceverificationofanovelrcmmechanismforaminimallyinvasivesurgicalrobot AT liangzhixin designandperformanceverificationofanovelrcmmechanismforaminimallyinvasivesurgicalrobot AT zhangboyang designandperformanceverificationofanovelrcmmechanismforaminimallyinvasivesurgicalrobot AT wanghaitao designandperformanceverificationofanovelrcmmechanismforaminimallyinvasivesurgicalrobot |