Cargando…

Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot

Minimally invasive surgical robots have the advantages of high positioning accuracy, good stability, and flexible operation, which can effectively improve the quality of surgery and reduce the difficulty for doctors to operate. However, in order to realize the translation of the existing RCM mechani...

Descripción completa

Detalles Bibliográficos
Autores principales: Shi, Hu, Liang, Zhixin, Zhang, Boyang, Wang, Haitao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963641/
https://www.ncbi.nlm.nih.gov/pubmed/36850959
http://dx.doi.org/10.3390/s23042361
_version_ 1784896303046590464
author Shi, Hu
Liang, Zhixin
Zhang, Boyang
Wang, Haitao
author_facet Shi, Hu
Liang, Zhixin
Zhang, Boyang
Wang, Haitao
author_sort Shi, Hu
collection PubMed
description Minimally invasive surgical robots have the advantages of high positioning accuracy, good stability, and flexible operation, which can effectively improve the quality of surgery and reduce the difficulty for doctors to operate. However, in order to realize the translation of the existing RCM mechanism, it is often necessary to add a mobile unit, which is often bulky and occupies most space above the patient’s body, thus causing interference to the operation. In this paper, a new type of planar RCM mechanism is proposed. Based on this mechanism, a 3-DOF robotic arm is designed, which can complete the required motion for surgery without adding a mobile unit. In this paper, the geometric model of the mechanism is first introduced, and the RCM point of the mechanism is proven during the motion process. Then, based on the establishment of the geometric model of the mechanism, a kinematics analysis of the mechanism is carried out. The singularity, the Jacobian matrix, and the kinematic performance of the mechanism are analyzed, and the working space of the mechanism is verified according to the kinematic equations. Finally, a prototype of the RCM mechanism was built, and its functionality was tested using a master–slave control strategy.
format Online
Article
Text
id pubmed-9963641
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99636412023-02-26 Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot Shi, Hu Liang, Zhixin Zhang, Boyang Wang, Haitao Sensors (Basel) Article Minimally invasive surgical robots have the advantages of high positioning accuracy, good stability, and flexible operation, which can effectively improve the quality of surgery and reduce the difficulty for doctors to operate. However, in order to realize the translation of the existing RCM mechanism, it is often necessary to add a mobile unit, which is often bulky and occupies most space above the patient’s body, thus causing interference to the operation. In this paper, a new type of planar RCM mechanism is proposed. Based on this mechanism, a 3-DOF robotic arm is designed, which can complete the required motion for surgery without adding a mobile unit. In this paper, the geometric model of the mechanism is first introduced, and the RCM point of the mechanism is proven during the motion process. Then, based on the establishment of the geometric model of the mechanism, a kinematics analysis of the mechanism is carried out. The singularity, the Jacobian matrix, and the kinematic performance of the mechanism are analyzed, and the working space of the mechanism is verified according to the kinematic equations. Finally, a prototype of the RCM mechanism was built, and its functionality was tested using a master–slave control strategy. MDPI 2023-02-20 /pmc/articles/PMC9963641/ /pubmed/36850959 http://dx.doi.org/10.3390/s23042361 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shi, Hu
Liang, Zhixin
Zhang, Boyang
Wang, Haitao
Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot
title Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot
title_full Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot
title_fullStr Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot
title_full_unstemmed Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot
title_short Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot
title_sort design and performance verification of a novel rcm mechanism for a minimally invasive surgical robot
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963641/
https://www.ncbi.nlm.nih.gov/pubmed/36850959
http://dx.doi.org/10.3390/s23042361
work_keys_str_mv AT shihu designandperformanceverificationofanovelrcmmechanismforaminimallyinvasivesurgicalrobot
AT liangzhixin designandperformanceverificationofanovelrcmmechanismforaminimallyinvasivesurgicalrobot
AT zhangboyang designandperformanceverificationofanovelrcmmechanismforaminimallyinvasivesurgicalrobot
AT wanghaitao designandperformanceverificationofanovelrcmmechanismforaminimallyinvasivesurgicalrobot