Cargando…
A Novel Baseline-Free Method for Damage Localization Using Guided Waves Based on Hyperbola Imaging Algorithm
Most imaging methods based on ultrasonic Lamb waves in structural health monitoring requires reference signals, recorded in the intact state. This paper focuses on a novel baseline-free method for damage localization using Lamb waves based on a hyperbolic algorithm. This method employs a special arr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963664/ https://www.ncbi.nlm.nih.gov/pubmed/36850649 http://dx.doi.org/10.3390/s23042050 |
_version_ | 1784896309717630976 |
---|---|
author | Xu, Jichao Zhu, Wujun Qiu, Xunlin Xiang, Yanxun |
author_facet | Xu, Jichao Zhu, Wujun Qiu, Xunlin Xiang, Yanxun |
author_sort | Xu, Jichao |
collection | PubMed |
description | Most imaging methods based on ultrasonic Lamb waves in structural health monitoring requires reference signals, recorded in the intact state. This paper focuses on a novel baseline-free method for damage localization using Lamb waves based on a hyperbolic algorithm. This method employs a special array with a relatively small number of transducers and only one branch of the hyperbola. The novel symmetrical array was arranged on plate structures to eliminate the direct waves. The time difference between the received signals at symmetrical sensors was obtained from the damage-scattered waves. The sequence of time difference for constructing the hyperbolic trajectory was calculated by the cross-correlation method. Numerical simulation and experimental measurements were implemented on an aluminum plate with a through-thickness hole in the current state. The imaging results show that both the damages outside and inside the diamond-shaped arrays can be localized, and the positioning error reaches the maximum for the diamond-shaped array with the minimum size. The results indicate that the position of the through-hole in the aluminum plate can be identified and localized by the proposed baseline-free method. |
format | Online Article Text |
id | pubmed-9963664 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99636642023-02-26 A Novel Baseline-Free Method for Damage Localization Using Guided Waves Based on Hyperbola Imaging Algorithm Xu, Jichao Zhu, Wujun Qiu, Xunlin Xiang, Yanxun Sensors (Basel) Article Most imaging methods based on ultrasonic Lamb waves in structural health monitoring requires reference signals, recorded in the intact state. This paper focuses on a novel baseline-free method for damage localization using Lamb waves based on a hyperbolic algorithm. This method employs a special array with a relatively small number of transducers and only one branch of the hyperbola. The novel symmetrical array was arranged on plate structures to eliminate the direct waves. The time difference between the received signals at symmetrical sensors was obtained from the damage-scattered waves. The sequence of time difference for constructing the hyperbolic trajectory was calculated by the cross-correlation method. Numerical simulation and experimental measurements were implemented on an aluminum plate with a through-thickness hole in the current state. The imaging results show that both the damages outside and inside the diamond-shaped arrays can be localized, and the positioning error reaches the maximum for the diamond-shaped array with the minimum size. The results indicate that the position of the through-hole in the aluminum plate can be identified and localized by the proposed baseline-free method. MDPI 2023-02-11 /pmc/articles/PMC9963664/ /pubmed/36850649 http://dx.doi.org/10.3390/s23042050 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xu, Jichao Zhu, Wujun Qiu, Xunlin Xiang, Yanxun A Novel Baseline-Free Method for Damage Localization Using Guided Waves Based on Hyperbola Imaging Algorithm |
title | A Novel Baseline-Free Method for Damage Localization Using Guided Waves Based on Hyperbola Imaging Algorithm |
title_full | A Novel Baseline-Free Method for Damage Localization Using Guided Waves Based on Hyperbola Imaging Algorithm |
title_fullStr | A Novel Baseline-Free Method for Damage Localization Using Guided Waves Based on Hyperbola Imaging Algorithm |
title_full_unstemmed | A Novel Baseline-Free Method for Damage Localization Using Guided Waves Based on Hyperbola Imaging Algorithm |
title_short | A Novel Baseline-Free Method for Damage Localization Using Guided Waves Based on Hyperbola Imaging Algorithm |
title_sort | novel baseline-free method for damage localization using guided waves based on hyperbola imaging algorithm |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9963664/ https://www.ncbi.nlm.nih.gov/pubmed/36850649 http://dx.doi.org/10.3390/s23042050 |
work_keys_str_mv | AT xujichao anovelbaselinefreemethodfordamagelocalizationusingguidedwavesbasedonhyperbolaimagingalgorithm AT zhuwujun anovelbaselinefreemethodfordamagelocalizationusingguidedwavesbasedonhyperbolaimagingalgorithm AT qiuxunlin anovelbaselinefreemethodfordamagelocalizationusingguidedwavesbasedonhyperbolaimagingalgorithm AT xiangyanxun anovelbaselinefreemethodfordamagelocalizationusingguidedwavesbasedonhyperbolaimagingalgorithm AT xujichao novelbaselinefreemethodfordamagelocalizationusingguidedwavesbasedonhyperbolaimagingalgorithm AT zhuwujun novelbaselinefreemethodfordamagelocalizationusingguidedwavesbasedonhyperbolaimagingalgorithm AT qiuxunlin novelbaselinefreemethodfordamagelocalizationusingguidedwavesbasedonhyperbolaimagingalgorithm AT xiangyanxun novelbaselinefreemethodfordamagelocalizationusingguidedwavesbasedonhyperbolaimagingalgorithm |