Cargando…

Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography

The electrocardiogram (ECG) is the standard method in clinical practice to non-invasively analyze the electrical activity of the heart, from electrodes placed on the body’s surface. The ECG can provide a cardiologist with relevant information to assess the condition of the heart and the possible pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Tiantian, Karel, Joël, Bonizzi, Pietro, Peeters, Ralf L. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9964356/
https://www.ncbi.nlm.nih.gov/pubmed/36850438
http://dx.doi.org/10.3390/s23041841
_version_ 1784896484317069312
author Wang, Tiantian
Karel, Joël
Bonizzi, Pietro
Peeters, Ralf L. M.
author_facet Wang, Tiantian
Karel, Joël
Bonizzi, Pietro
Peeters, Ralf L. M.
author_sort Wang, Tiantian
collection PubMed
description The electrocardiogram (ECG) is the standard method in clinical practice to non-invasively analyze the electrical activity of the heart, from electrodes placed on the body’s surface. The ECG can provide a cardiologist with relevant information to assess the condition of the heart and the possible presence of cardiac pathology. Nonetheless, the global view of the heart’s electrical activity given by the ECG cannot provide fully detailed and localized information about abnormal electrical propagation patterns and corresponding substrates on the surface of the heart. Electrocardiographic imaging, also known as the inverse problem in electrocardiography, tries to overcome these limitations by non-invasively reconstructing the heart surface potentials, starting from the corresponding body surface potentials, and the geometry of the torso and the heart. This problem is ill-posed, and regularization techniques are needed to achieve a stable and accurate solution. The standard approach is to use zero-order Tikhonov regularization and the L-curve approach to choose the optimal value for the regularization parameter. However, different methods have been proposed for computing the optimal value of the regularization parameter. Moreover, regardless of the estimation method used, this may still lead to over-regularization or under-regularization. In order to gain a better understanding of the effects of the choice of regularization parameter value, in this study, we first focused on the regularization parameter itself, and investigated its influence on the accuracy of the reconstruction of heart surface potentials, by assessing the reconstruction accuracy with high-precision simultaneous heart and torso recordings from four dogs. For this, we analyzed a sufficiently large range of parameter values. Secondly, we evaluated the performance of five different methods for the estimation of the regularization parameter, also in view of the results of the first analysis. Thirdly, we investigated the effect of using a fixed value of the regularization parameter across all reconstructed beats. Accuracy was measured in terms of the quality of reconstruction of the heart surface potentials and estimation of the activation and recovery times, when compared with ground truth recordings from the experimental dog data. Results show that values of the regularization parameter in the range (0.01–0.03) provide the best accuracy, and that the three best-performing estimation methods (L-Curve, Zero-Crossing, and CRESO) give values in this range. Moreover, a fixed value of the regularization parameter could achieve very similar performance to the beat-specific parameter values calculated by the different estimation methods. These findings are relevant as they suggest that regularization parameter estimation methods may provide the accurate reconstruction of heart surface potentials only for specific ranges of regularization parameter values, and that using a fixed value of the regularization parameter may represent a valid alternative, especially when computational efficiency or consistency across time is required.
format Online
Article
Text
id pubmed-9964356
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99643562023-02-26 Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography Wang, Tiantian Karel, Joël Bonizzi, Pietro Peeters, Ralf L. M. Sensors (Basel) Article The electrocardiogram (ECG) is the standard method in clinical practice to non-invasively analyze the electrical activity of the heart, from electrodes placed on the body’s surface. The ECG can provide a cardiologist with relevant information to assess the condition of the heart and the possible presence of cardiac pathology. Nonetheless, the global view of the heart’s electrical activity given by the ECG cannot provide fully detailed and localized information about abnormal electrical propagation patterns and corresponding substrates on the surface of the heart. Electrocardiographic imaging, also known as the inverse problem in electrocardiography, tries to overcome these limitations by non-invasively reconstructing the heart surface potentials, starting from the corresponding body surface potentials, and the geometry of the torso and the heart. This problem is ill-posed, and regularization techniques are needed to achieve a stable and accurate solution. The standard approach is to use zero-order Tikhonov regularization and the L-curve approach to choose the optimal value for the regularization parameter. However, different methods have been proposed for computing the optimal value of the regularization parameter. Moreover, regardless of the estimation method used, this may still lead to over-regularization or under-regularization. In order to gain a better understanding of the effects of the choice of regularization parameter value, in this study, we first focused on the regularization parameter itself, and investigated its influence on the accuracy of the reconstruction of heart surface potentials, by assessing the reconstruction accuracy with high-precision simultaneous heart and torso recordings from four dogs. For this, we analyzed a sufficiently large range of parameter values. Secondly, we evaluated the performance of five different methods for the estimation of the regularization parameter, also in view of the results of the first analysis. Thirdly, we investigated the effect of using a fixed value of the regularization parameter across all reconstructed beats. Accuracy was measured in terms of the quality of reconstruction of the heart surface potentials and estimation of the activation and recovery times, when compared with ground truth recordings from the experimental dog data. Results show that values of the regularization parameter in the range (0.01–0.03) provide the best accuracy, and that the three best-performing estimation methods (L-Curve, Zero-Crossing, and CRESO) give values in this range. Moreover, a fixed value of the regularization parameter could achieve very similar performance to the beat-specific parameter values calculated by the different estimation methods. These findings are relevant as they suggest that regularization parameter estimation methods may provide the accurate reconstruction of heart surface potentials only for specific ranges of regularization parameter values, and that using a fixed value of the regularization parameter may represent a valid alternative, especially when computational efficiency or consistency across time is required. MDPI 2023-02-07 /pmc/articles/PMC9964356/ /pubmed/36850438 http://dx.doi.org/10.3390/s23041841 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Tiantian
Karel, Joël
Bonizzi, Pietro
Peeters, Ralf L. M.
Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography
title Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography
title_full Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography
title_fullStr Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography
title_full_unstemmed Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography
title_short Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography
title_sort influence of the tikhonov regularization parameter on the accuracy of the inverse problem in electrocardiography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9964356/
https://www.ncbi.nlm.nih.gov/pubmed/36850438
http://dx.doi.org/10.3390/s23041841
work_keys_str_mv AT wangtiantian influenceofthetikhonovregularizationparameterontheaccuracyoftheinverseprobleminelectrocardiography
AT kareljoel influenceofthetikhonovregularizationparameterontheaccuracyoftheinverseprobleminelectrocardiography
AT bonizzipietro influenceofthetikhonovregularizationparameterontheaccuracyoftheinverseprobleminelectrocardiography
AT peetersralflm influenceofthetikhonovregularizationparameterontheaccuracyoftheinverseprobleminelectrocardiography