Cargando…

Experimental Investigation of the Effect of Steel Fibers on the Flexural Behavior of Corroded Prestressed Reinforced Concrete Beams

Rebar corrosion and its consequences are one of the most common damages to reinforced concrete (RC) structures. In structures with greater sensitivity, such as prestressed reinforced concrete (PRC) structures, where steel elements, including prestressed tendons, play a more significant role in suppo...

Descripción completa

Detalles Bibliográficos
Autores principales: Hassanvand, Pouya, Rezaie, Freydoon, Kioumarsi, Mahdi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9964733/
https://www.ncbi.nlm.nih.gov/pubmed/36837260
http://dx.doi.org/10.3390/ma16041629
_version_ 1784896581234851840
author Hassanvand, Pouya
Rezaie, Freydoon
Kioumarsi, Mahdi
author_facet Hassanvand, Pouya
Rezaie, Freydoon
Kioumarsi, Mahdi
author_sort Hassanvand, Pouya
collection PubMed
description Rebar corrosion and its consequences are one of the most common damages to reinforced concrete (RC) structures. In structures with greater sensitivity, such as prestressed reinforced concrete (PRC) structures, where steel elements, including prestressed tendons, play a more significant role in supporting the structure, the importance of this issue increases. Methods for repairing and reinforcing such structures have been developed, including incorporating fibers into the concrete mixture to improve its mechanical properties, particularly its bending resistance. This paper presents the results of an experiment that studied the influence of steel fibers on the flexural behavior of PRC beams subjected to accelerated corrosion. Twelve beams with a rectangular cross-section of 150 mm × 300 mm and a length of 2000 mm were fabricated. The steel fibers used in the experiment were corrugated and hooked-end types, with volume fractions of 0.5% and 1.0% in the concrete. Nine beams were subjected to accelerated corrosion testing, with three of them being without fibers and the remaining six being reinforced with steel fibers at volume fractions of 0.5% and 1.0%. Each group of three beams was exposed to three different levels of corrosion, namely 5%, 10%, and 15%. The specimens were tested after exposure to corrosion through a four-point bending load. The accelerated corrosion was induced using an electric current on the prestressing tendons. The results indicated that different levels of corrosion reduced the final bearing capacity and other behavioral characteristics of the specimen, including the amount of energy absorption, effective hardness, and midspan displacement. Adding fibers to the concrete mixture positively affects the compensation of these reduced capacities. Moreover, the amount of this compensation was directly correlated with the volume fraction of used fibers.
format Online
Article
Text
id pubmed-9964733
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99647332023-02-26 Experimental Investigation of the Effect of Steel Fibers on the Flexural Behavior of Corroded Prestressed Reinforced Concrete Beams Hassanvand, Pouya Rezaie, Freydoon Kioumarsi, Mahdi Materials (Basel) Article Rebar corrosion and its consequences are one of the most common damages to reinforced concrete (RC) structures. In structures with greater sensitivity, such as prestressed reinforced concrete (PRC) structures, where steel elements, including prestressed tendons, play a more significant role in supporting the structure, the importance of this issue increases. Methods for repairing and reinforcing such structures have been developed, including incorporating fibers into the concrete mixture to improve its mechanical properties, particularly its bending resistance. This paper presents the results of an experiment that studied the influence of steel fibers on the flexural behavior of PRC beams subjected to accelerated corrosion. Twelve beams with a rectangular cross-section of 150 mm × 300 mm and a length of 2000 mm were fabricated. The steel fibers used in the experiment were corrugated and hooked-end types, with volume fractions of 0.5% and 1.0% in the concrete. Nine beams were subjected to accelerated corrosion testing, with three of them being without fibers and the remaining six being reinforced with steel fibers at volume fractions of 0.5% and 1.0%. Each group of three beams was exposed to three different levels of corrosion, namely 5%, 10%, and 15%. The specimens were tested after exposure to corrosion through a four-point bending load. The accelerated corrosion was induced using an electric current on the prestressing tendons. The results indicated that different levels of corrosion reduced the final bearing capacity and other behavioral characteristics of the specimen, including the amount of energy absorption, effective hardness, and midspan displacement. Adding fibers to the concrete mixture positively affects the compensation of these reduced capacities. Moreover, the amount of this compensation was directly correlated with the volume fraction of used fibers. MDPI 2023-02-15 /pmc/articles/PMC9964733/ /pubmed/36837260 http://dx.doi.org/10.3390/ma16041629 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hassanvand, Pouya
Rezaie, Freydoon
Kioumarsi, Mahdi
Experimental Investigation of the Effect of Steel Fibers on the Flexural Behavior of Corroded Prestressed Reinforced Concrete Beams
title Experimental Investigation of the Effect of Steel Fibers on the Flexural Behavior of Corroded Prestressed Reinforced Concrete Beams
title_full Experimental Investigation of the Effect of Steel Fibers on the Flexural Behavior of Corroded Prestressed Reinforced Concrete Beams
title_fullStr Experimental Investigation of the Effect of Steel Fibers on the Flexural Behavior of Corroded Prestressed Reinforced Concrete Beams
title_full_unstemmed Experimental Investigation of the Effect of Steel Fibers on the Flexural Behavior of Corroded Prestressed Reinforced Concrete Beams
title_short Experimental Investigation of the Effect of Steel Fibers on the Flexural Behavior of Corroded Prestressed Reinforced Concrete Beams
title_sort experimental investigation of the effect of steel fibers on the flexural behavior of corroded prestressed reinforced concrete beams
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9964733/
https://www.ncbi.nlm.nih.gov/pubmed/36837260
http://dx.doi.org/10.3390/ma16041629
work_keys_str_mv AT hassanvandpouya experimentalinvestigationoftheeffectofsteelfibersontheflexuralbehaviorofcorrodedprestressedreinforcedconcretebeams
AT rezaiefreydoon experimentalinvestigationoftheeffectofsteelfibersontheflexuralbehaviorofcorrodedprestressedreinforcedconcretebeams
AT kioumarsimahdi experimentalinvestigationoftheeffectofsteelfibersontheflexuralbehaviorofcorrodedprestressedreinforcedconcretebeams