Cargando…

Automatic Detection of the Orientation of Strain Gauges Bonded on Composite Materials with Polymer Matrix, in Order to Reduce the Measurement Errors

Composite materials with a polymer matrix are used on a large scale to make light structures that involve high responsibility. The failure mechanisms of composite materials are very complex and for this reason, advanced techniques for damage detection and the assessment of structural integrity are r...

Descripción completa

Detalles Bibliográficos
Autores principales: Serban, Alexandru, Barsanescu, Paul Doru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9964756/
https://www.ncbi.nlm.nih.gov/pubmed/36850160
http://dx.doi.org/10.3390/polym15040876
_version_ 1784896587032428544
author Serban, Alexandru
Barsanescu, Paul Doru
author_facet Serban, Alexandru
Barsanescu, Paul Doru
author_sort Serban, Alexandru
collection PubMed
description Composite materials with a polymer matrix are used on a large scale to make light structures that involve high responsibility. The failure mechanisms of composite materials are very complex and for this reason, advanced techniques for damage detection and the assessment of structural integrity are required. The continuous structural health monitoring (SHM) uses nondestructive testing (NDT) techniques, sensors integrated into the structures, computers and dedicated software. This article presents a new automatic and precise method for detecting the orientation of strain gauges glued onto composite materials with a polymer matrix. The automatic identification of both the directions of the reinforcing fibers and that of the orientation of the strain gauge, respectively, allows for the calculation of the angle between these two directions. By knowing the difference between the nominal value of this angle and the value actually obtained after gluing the strain gauge, corrections obtained by calculation on the experimental values can be applied, using equations found in specialized literature. In this way, a drastic reduction of measurement errors introduced by the misalignment of strain gauges glued on composite materials can be achieved, resulting in a significant increase of measurement accuracy, which contributes to increasing the security of the monitored structures.
format Online
Article
Text
id pubmed-9964756
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99647562023-02-26 Automatic Detection of the Orientation of Strain Gauges Bonded on Composite Materials with Polymer Matrix, in Order to Reduce the Measurement Errors Serban, Alexandru Barsanescu, Paul Doru Polymers (Basel) Article Composite materials with a polymer matrix are used on a large scale to make light structures that involve high responsibility. The failure mechanisms of composite materials are very complex and for this reason, advanced techniques for damage detection and the assessment of structural integrity are required. The continuous structural health monitoring (SHM) uses nondestructive testing (NDT) techniques, sensors integrated into the structures, computers and dedicated software. This article presents a new automatic and precise method for detecting the orientation of strain gauges glued onto composite materials with a polymer matrix. The automatic identification of both the directions of the reinforcing fibers and that of the orientation of the strain gauge, respectively, allows for the calculation of the angle between these two directions. By knowing the difference between the nominal value of this angle and the value actually obtained after gluing the strain gauge, corrections obtained by calculation on the experimental values can be applied, using equations found in specialized literature. In this way, a drastic reduction of measurement errors introduced by the misalignment of strain gauges glued on composite materials can be achieved, resulting in a significant increase of measurement accuracy, which contributes to increasing the security of the monitored structures. MDPI 2023-02-10 /pmc/articles/PMC9964756/ /pubmed/36850160 http://dx.doi.org/10.3390/polym15040876 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Serban, Alexandru
Barsanescu, Paul Doru
Automatic Detection of the Orientation of Strain Gauges Bonded on Composite Materials with Polymer Matrix, in Order to Reduce the Measurement Errors
title Automatic Detection of the Orientation of Strain Gauges Bonded on Composite Materials with Polymer Matrix, in Order to Reduce the Measurement Errors
title_full Automatic Detection of the Orientation of Strain Gauges Bonded on Composite Materials with Polymer Matrix, in Order to Reduce the Measurement Errors
title_fullStr Automatic Detection of the Orientation of Strain Gauges Bonded on Composite Materials with Polymer Matrix, in Order to Reduce the Measurement Errors
title_full_unstemmed Automatic Detection of the Orientation of Strain Gauges Bonded on Composite Materials with Polymer Matrix, in Order to Reduce the Measurement Errors
title_short Automatic Detection of the Orientation of Strain Gauges Bonded on Composite Materials with Polymer Matrix, in Order to Reduce the Measurement Errors
title_sort automatic detection of the orientation of strain gauges bonded on composite materials with polymer matrix, in order to reduce the measurement errors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9964756/
https://www.ncbi.nlm.nih.gov/pubmed/36850160
http://dx.doi.org/10.3390/polym15040876
work_keys_str_mv AT serbanalexandru automaticdetectionoftheorientationofstraingaugesbondedoncompositematerialswithpolymermatrixinordertoreducethemeasurementerrors
AT barsanescupauldoru automaticdetectionoftheorientationofstraingaugesbondedoncompositematerialswithpolymermatrixinordertoreducethemeasurementerrors