3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems
Background: In recent years, three-dimensional exoscopes have been increasingly applied in neurosurgery. Multiple exoscopic systems are available, all offering specific features. In this study, we assessed practical and visualization performance of four different exoscopic systems in a highly challe...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966143/ https://www.ncbi.nlm.nih.gov/pubmed/36836941 http://dx.doi.org/10.3390/life13020584 |
_version_ | 1784896942611890176 |
---|---|
author | Hafez, Ahmad Haeren, Roel Huhtakangas, Justiina Nurminen, Ville Niemelä, Mika Lehecka, Martin |
author_facet | Hafez, Ahmad Haeren, Roel Huhtakangas, Justiina Nurminen, Ville Niemelä, Mika Lehecka, Martin |
author_sort | Hafez, Ahmad |
collection | PubMed |
description | Background: In recent years, three-dimensional exoscopes have been increasingly applied in neurosurgery. Multiple exoscopic systems are available, all offering specific features. In this study, we assessed practical and visualization performance of four different exoscopic systems in a highly challenging microsurgical procedure, and evaluated whether these affected the quality of work. Methods: We included four different exoscopes: Olympus ORBEYE, Zeiss KINEVO, Storz VITOM, and Aesculap AEOS. With each exoscope, ten experimental bypass procedures were carried out on chicken wing vessels at a depth of 3 cm. We evaluated the quality of the anastomoses, the practical considerations for the setup of the exoscopic systems, and the visualization quality by tracking the number of unnecessary movements. Results: All included exoscopes enabled us to perform the bypass procedures with mostly adequate or excellent results. Surgically, the most pronounced difference between the exoscopes was the duration of the procedure, which was mainly due to the number of unnecessary movements. Practically, the exoscopes differ highly which is important when considering which exoscope to apply. Conclusions: This is the first study comparing different exoscope systems while performing the same challenging microsurgical procedure. We found major practical differences between the exoscopes that determine the suitability of an exoscope based on the demands and conditions of the surgical procedure. Therefore, preprocedural practical training with the exoscope is required. |
format | Online Article Text |
id | pubmed-9966143 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99661432023-02-26 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems Hafez, Ahmad Haeren, Roel Huhtakangas, Justiina Nurminen, Ville Niemelä, Mika Lehecka, Martin Life (Basel) Article Background: In recent years, three-dimensional exoscopes have been increasingly applied in neurosurgery. Multiple exoscopic systems are available, all offering specific features. In this study, we assessed practical and visualization performance of four different exoscopic systems in a highly challenging microsurgical procedure, and evaluated whether these affected the quality of work. Methods: We included four different exoscopes: Olympus ORBEYE, Zeiss KINEVO, Storz VITOM, and Aesculap AEOS. With each exoscope, ten experimental bypass procedures were carried out on chicken wing vessels at a depth of 3 cm. We evaluated the quality of the anastomoses, the practical considerations for the setup of the exoscopic systems, and the visualization quality by tracking the number of unnecessary movements. Results: All included exoscopes enabled us to perform the bypass procedures with mostly adequate or excellent results. Surgically, the most pronounced difference between the exoscopes was the duration of the procedure, which was mainly due to the number of unnecessary movements. Practically, the exoscopes differ highly which is important when considering which exoscope to apply. Conclusions: This is the first study comparing different exoscope systems while performing the same challenging microsurgical procedure. We found major practical differences between the exoscopes that determine the suitability of an exoscope based on the demands and conditions of the surgical procedure. Therefore, preprocedural practical training with the exoscope is required. MDPI 2023-02-19 /pmc/articles/PMC9966143/ /pubmed/36836941 http://dx.doi.org/10.3390/life13020584 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hafez, Ahmad Haeren, Roel Huhtakangas, Justiina Nurminen, Ville Niemelä, Mika Lehecka, Martin 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems |
title | 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems |
title_full | 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems |
title_fullStr | 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems |
title_full_unstemmed | 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems |
title_short | 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems |
title_sort | 3d exoscopes in experimental microanastomosis: a comparison of different systems |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966143/ https://www.ncbi.nlm.nih.gov/pubmed/36836941 http://dx.doi.org/10.3390/life13020584 |
work_keys_str_mv | AT hafezahmad 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems AT haerenroel 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems AT huhtakangasjustiina 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems AT nurminenville 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems AT niemelamika 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems AT leheckamartin 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems |