3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems

Background: In recent years, three-dimensional exoscopes have been increasingly applied in neurosurgery. Multiple exoscopic systems are available, all offering specific features. In this study, we assessed practical and visualization performance of four different exoscopic systems in a highly challe...

Descripción completa

Detalles Bibliográficos
Autores principales: Hafez, Ahmad, Haeren, Roel, Huhtakangas, Justiina, Nurminen, Ville, Niemelä, Mika, Lehecka, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966143/
https://www.ncbi.nlm.nih.gov/pubmed/36836941
http://dx.doi.org/10.3390/life13020584
_version_ 1784896942611890176
author Hafez, Ahmad
Haeren, Roel
Huhtakangas, Justiina
Nurminen, Ville
Niemelä, Mika
Lehecka, Martin
author_facet Hafez, Ahmad
Haeren, Roel
Huhtakangas, Justiina
Nurminen, Ville
Niemelä, Mika
Lehecka, Martin
author_sort Hafez, Ahmad
collection PubMed
description Background: In recent years, three-dimensional exoscopes have been increasingly applied in neurosurgery. Multiple exoscopic systems are available, all offering specific features. In this study, we assessed practical and visualization performance of four different exoscopic systems in a highly challenging microsurgical procedure, and evaluated whether these affected the quality of work. Methods: We included four different exoscopes: Olympus ORBEYE, Zeiss KINEVO, Storz VITOM, and Aesculap AEOS. With each exoscope, ten experimental bypass procedures were carried out on chicken wing vessels at a depth of 3 cm. We evaluated the quality of the anastomoses, the practical considerations for the setup of the exoscopic systems, and the visualization quality by tracking the number of unnecessary movements. Results: All included exoscopes enabled us to perform the bypass procedures with mostly adequate or excellent results. Surgically, the most pronounced difference between the exoscopes was the duration of the procedure, which was mainly due to the number of unnecessary movements. Practically, the exoscopes differ highly which is important when considering which exoscope to apply. Conclusions: This is the first study comparing different exoscope systems while performing the same challenging microsurgical procedure. We found major practical differences between the exoscopes that determine the suitability of an exoscope based on the demands and conditions of the surgical procedure. Therefore, preprocedural practical training with the exoscope is required.
format Online
Article
Text
id pubmed-9966143
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99661432023-02-26 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems Hafez, Ahmad Haeren, Roel Huhtakangas, Justiina Nurminen, Ville Niemelä, Mika Lehecka, Martin Life (Basel) Article Background: In recent years, three-dimensional exoscopes have been increasingly applied in neurosurgery. Multiple exoscopic systems are available, all offering specific features. In this study, we assessed practical and visualization performance of four different exoscopic systems in a highly challenging microsurgical procedure, and evaluated whether these affected the quality of work. Methods: We included four different exoscopes: Olympus ORBEYE, Zeiss KINEVO, Storz VITOM, and Aesculap AEOS. With each exoscope, ten experimental bypass procedures were carried out on chicken wing vessels at a depth of 3 cm. We evaluated the quality of the anastomoses, the practical considerations for the setup of the exoscopic systems, and the visualization quality by tracking the number of unnecessary movements. Results: All included exoscopes enabled us to perform the bypass procedures with mostly adequate or excellent results. Surgically, the most pronounced difference between the exoscopes was the duration of the procedure, which was mainly due to the number of unnecessary movements. Practically, the exoscopes differ highly which is important when considering which exoscope to apply. Conclusions: This is the first study comparing different exoscope systems while performing the same challenging microsurgical procedure. We found major practical differences between the exoscopes that determine the suitability of an exoscope based on the demands and conditions of the surgical procedure. Therefore, preprocedural practical training with the exoscope is required. MDPI 2023-02-19 /pmc/articles/PMC9966143/ /pubmed/36836941 http://dx.doi.org/10.3390/life13020584 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hafez, Ahmad
Haeren, Roel
Huhtakangas, Justiina
Nurminen, Ville
Niemelä, Mika
Lehecka, Martin
3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems
title 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems
title_full 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems
title_fullStr 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems
title_full_unstemmed 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems
title_short 3D Exoscopes in Experimental Microanastomosis: A Comparison of Different Systems
title_sort 3d exoscopes in experimental microanastomosis: a comparison of different systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966143/
https://www.ncbi.nlm.nih.gov/pubmed/36836941
http://dx.doi.org/10.3390/life13020584
work_keys_str_mv AT hafezahmad 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems
AT haerenroel 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems
AT huhtakangasjustiina 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems
AT nurminenville 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems
AT niemelamika 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems
AT leheckamartin 3dexoscopesinexperimentalmicroanastomosisacomparisonofdifferentsystems