Development of a Biomechanical Device for Parameter Quantification Associated with the Sit-to-Stand Movement

The “sit-to-stand” (STS) movement is essential during activities of daily living (ADL). In individuals with physical-motor diseases, its execution and repetition increases activity levels, which is crucial for a good motor rehabilitation process and daily training. Interestingly, there are no sit-to...

Descripción completa

Detalles Bibliográficos
Autores principales: Oliveira, Natacha, Carvalho, Filipe, Laíns, Jorge, Rasteiro, Deolinda, Roseiro, Luis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966365/
https://www.ncbi.nlm.nih.gov/pubmed/36850435
http://dx.doi.org/10.3390/s23041837
_version_ 1784896999004307456
author Oliveira, Natacha
Carvalho, Filipe
Laíns, Jorge
Rasteiro, Deolinda
Roseiro, Luis
author_facet Oliveira, Natacha
Carvalho, Filipe
Laíns, Jorge
Rasteiro, Deolinda
Roseiro, Luis
author_sort Oliveira, Natacha
collection PubMed
description The “sit-to-stand” (STS) movement is essential during activities of daily living (ADL). In individuals with physical-motor diseases, its execution and repetition increases activity levels, which is crucial for a good motor rehabilitation process and daily training. Interestingly, there are no sit-to-stand devices that allow a quantitative assessment of the key variables that happen during STS, and there is a need to come up with a new device. This work presents a developed biomechanical support device that measures the force of the upper limbs during the STS movement, aiming to motivate and encourage people undergoing physical therapy in the lower limbs. The device uses two instrumented beams and allows real-time visualization of both arms’ applied force and it records the data for post-processing. The device was tested with a well-defined protocol on a group of 34 healthy young volunteers and an elderly group of 16 volunteers from a continuing care unit. The system showed robust strength and stiffness, good usability, and a user interface that acquired and recorded data effectively, allowing one to observe force-time during the execution of the movement through the application interface developed and in recording data for post-processing. Asymmetries in the applied forces in the STS movement between the upper limbs were identified, particularly in volunteers of the continuing care unit. From the application and the registered data, it can be observed that volunteers with motor problems in the lower limbs performed more strength in their arms to compensate. As expected, the maximum average strength of the healthy volunteers (both arms: force = 105 Newton) was higher than that of the volunteers from the continuing care unit (right arm: force = 54 Newton; left arm: force = 56 Newton). Among others, moderate correlations were observed between weight-applied and height-applied forces and there was a moderately high correlation between the Sequential Clinical Assessment of Respiratory Function (SCAR-F score) and time to perform the movement. Based on the obtained results, the developed device can be a helpful tool for monitoring the evaluation of a patient with limitations in the upper and lower limbs. In addition, the developed system allows for easy evolution, such as including a barometric platform and implementing serious games that can stimulate the execution of the STS movement.
format Online
Article
Text
id pubmed-9966365
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99663652023-02-26 Development of a Biomechanical Device for Parameter Quantification Associated with the Sit-to-Stand Movement Oliveira, Natacha Carvalho, Filipe Laíns, Jorge Rasteiro, Deolinda Roseiro, Luis Sensors (Basel) Article The “sit-to-stand” (STS) movement is essential during activities of daily living (ADL). In individuals with physical-motor diseases, its execution and repetition increases activity levels, which is crucial for a good motor rehabilitation process and daily training. Interestingly, there are no sit-to-stand devices that allow a quantitative assessment of the key variables that happen during STS, and there is a need to come up with a new device. This work presents a developed biomechanical support device that measures the force of the upper limbs during the STS movement, aiming to motivate and encourage people undergoing physical therapy in the lower limbs. The device uses two instrumented beams and allows real-time visualization of both arms’ applied force and it records the data for post-processing. The device was tested with a well-defined protocol on a group of 34 healthy young volunteers and an elderly group of 16 volunteers from a continuing care unit. The system showed robust strength and stiffness, good usability, and a user interface that acquired and recorded data effectively, allowing one to observe force-time during the execution of the movement through the application interface developed and in recording data for post-processing. Asymmetries in the applied forces in the STS movement between the upper limbs were identified, particularly in volunteers of the continuing care unit. From the application and the registered data, it can be observed that volunteers with motor problems in the lower limbs performed more strength in their arms to compensate. As expected, the maximum average strength of the healthy volunteers (both arms: force = 105 Newton) was higher than that of the volunteers from the continuing care unit (right arm: force = 54 Newton; left arm: force = 56 Newton). Among others, moderate correlations were observed between weight-applied and height-applied forces and there was a moderately high correlation between the Sequential Clinical Assessment of Respiratory Function (SCAR-F score) and time to perform the movement. Based on the obtained results, the developed device can be a helpful tool for monitoring the evaluation of a patient with limitations in the upper and lower limbs. In addition, the developed system allows for easy evolution, such as including a barometric platform and implementing serious games that can stimulate the execution of the STS movement. MDPI 2023-02-07 /pmc/articles/PMC9966365/ /pubmed/36850435 http://dx.doi.org/10.3390/s23041837 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oliveira, Natacha
Carvalho, Filipe
Laíns, Jorge
Rasteiro, Deolinda
Roseiro, Luis
Development of a Biomechanical Device for Parameter Quantification Associated with the Sit-to-Stand Movement
title Development of a Biomechanical Device for Parameter Quantification Associated with the Sit-to-Stand Movement
title_full Development of a Biomechanical Device for Parameter Quantification Associated with the Sit-to-Stand Movement
title_fullStr Development of a Biomechanical Device for Parameter Quantification Associated with the Sit-to-Stand Movement
title_full_unstemmed Development of a Biomechanical Device for Parameter Quantification Associated with the Sit-to-Stand Movement
title_short Development of a Biomechanical Device for Parameter Quantification Associated with the Sit-to-Stand Movement
title_sort development of a biomechanical device for parameter quantification associated with the sit-to-stand movement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966365/
https://www.ncbi.nlm.nih.gov/pubmed/36850435
http://dx.doi.org/10.3390/s23041837
work_keys_str_mv AT oliveiranatacha developmentofabiomechanicaldeviceforparameterquantificationassociatedwiththesittostandmovement
AT carvalhofilipe developmentofabiomechanicaldeviceforparameterquantificationassociatedwiththesittostandmovement
AT lainsjorge developmentofabiomechanicaldeviceforparameterquantificationassociatedwiththesittostandmovement
AT rasteirodeolinda developmentofabiomechanicaldeviceforparameterquantificationassociatedwiththesittostandmovement
AT roseiroluis developmentofabiomechanicaldeviceforparameterquantificationassociatedwiththesittostandmovement