Cargando…

Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes

Due to its important environmental role, the analysis of trace metals in natural waters is attracting increasing attention; consequently, faster and more accurate analytical methods are now needed to reach even lower limits of detection. In this work, we propose the use of electro-membrane extractio...

Descripción completa

Detalles Bibliográficos
Autores principales: Pinto, Juan J., Mendiguchía, Carolina, López-López, José A., Martín-Barata, Mabel, Silva, Macarena, Moreno, Carlos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966385/
https://www.ncbi.nlm.nih.gov/pubmed/36837655
http://dx.doi.org/10.3390/membranes13020152
_version_ 1784897003727093760
author Pinto, Juan J.
Mendiguchía, Carolina
López-López, José A.
Martín-Barata, Mabel
Silva, Macarena
Moreno, Carlos
author_facet Pinto, Juan J.
Mendiguchía, Carolina
López-López, José A.
Martín-Barata, Mabel
Silva, Macarena
Moreno, Carlos
author_sort Pinto, Juan J.
collection PubMed
description Due to its important environmental role, the analysis of trace metals in natural waters is attracting increasing attention; consequently, faster and more accurate analytical methods are now needed to reach even lower limits of detection. In this work, we propose the use of electro-membrane extraction (EME) to improve analytical methods based on hollow fiber liquid phase micro-extraction (HFLPME). Specifically, an EME-based method for the determination of trace Ni in seawater has been developed, using an HFLPME system with di-2-ethylhexyl phosphoric acid (DEHPA) in kerosene as a chemical carrier, followed by instrumental determination by graphite furnace atomic absorption spectroscopy (GFAAS). Under optimum conditions, Ni was pre-concentrated 180 ± 17 times after 15 min, using sample pH = 5.5, the concentration of DEHPA 0.9 M in the liquid membranes, and 1.9 M HNO(3) in the acceptor solution, as well as an electric potential of 25 V with the sample being stirred at 500 rpm. When compared with other HFLPME systems for pre-concentration of trace Ni in seawater in the absence of electric potential, the enrichment factor was improved 2.2 times, while the time of extraction was reduced an 89%. The limit of detection of the new method was 23.3 ng L(−1), and both its applicability and accuracy were successfully evaluated by analyzing Ni concentration in a seawater-certified reference material (BCR-403), showing the reliability of EME for sample preparation in the determination of trace metals in marine water samples.
format Online
Article
Text
id pubmed-9966385
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99663852023-02-26 Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes Pinto, Juan J. Mendiguchía, Carolina López-López, José A. Martín-Barata, Mabel Silva, Macarena Moreno, Carlos Membranes (Basel) Article Due to its important environmental role, the analysis of trace metals in natural waters is attracting increasing attention; consequently, faster and more accurate analytical methods are now needed to reach even lower limits of detection. In this work, we propose the use of electro-membrane extraction (EME) to improve analytical methods based on hollow fiber liquid phase micro-extraction (HFLPME). Specifically, an EME-based method for the determination of trace Ni in seawater has been developed, using an HFLPME system with di-2-ethylhexyl phosphoric acid (DEHPA) in kerosene as a chemical carrier, followed by instrumental determination by graphite furnace atomic absorption spectroscopy (GFAAS). Under optimum conditions, Ni was pre-concentrated 180 ± 17 times after 15 min, using sample pH = 5.5, the concentration of DEHPA 0.9 M in the liquid membranes, and 1.9 M HNO(3) in the acceptor solution, as well as an electric potential of 25 V with the sample being stirred at 500 rpm. When compared with other HFLPME systems for pre-concentration of trace Ni in seawater in the absence of electric potential, the enrichment factor was improved 2.2 times, while the time of extraction was reduced an 89%. The limit of detection of the new method was 23.3 ng L(−1), and both its applicability and accuracy were successfully evaluated by analyzing Ni concentration in a seawater-certified reference material (BCR-403), showing the reliability of EME for sample preparation in the determination of trace metals in marine water samples. MDPI 2023-01-24 /pmc/articles/PMC9966385/ /pubmed/36837655 http://dx.doi.org/10.3390/membranes13020152 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pinto, Juan J.
Mendiguchía, Carolina
López-López, José A.
Martín-Barata, Mabel
Silva, Macarena
Moreno, Carlos
Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes
title Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes
title_full Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes
title_fullStr Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes
title_full_unstemmed Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes
title_short Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes
title_sort improvement of advanced sample preparation systems for the determination of trace ni in seawater by electro-membranes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966385/
https://www.ncbi.nlm.nih.gov/pubmed/36837655
http://dx.doi.org/10.3390/membranes13020152
work_keys_str_mv AT pintojuanj improvementofadvancedsamplepreparationsystemsforthedeterminationoftraceniinseawaterbyelectromembranes
AT mendiguchiacarolina improvementofadvancedsamplepreparationsystemsforthedeterminationoftraceniinseawaterbyelectromembranes
AT lopezlopezjosea improvementofadvancedsamplepreparationsystemsforthedeterminationoftraceniinseawaterbyelectromembranes
AT martinbaratamabel improvementofadvancedsamplepreparationsystemsforthedeterminationoftraceniinseawaterbyelectromembranes
AT silvamacarena improvementofadvancedsamplepreparationsystemsforthedeterminationoftraceniinseawaterbyelectromembranes
AT morenocarlos improvementofadvancedsamplepreparationsystemsforthedeterminationoftraceniinseawaterbyelectromembranes