Cargando…
Port Placement Variations for Robotic Lung Resection: Focusing on Their History, Conventional Look-Up-View and Horizontal Open-Thoracotomy-View Techniques, and More
This is a narrative review that summarizes the variations in approaches and port placements used for performing robotic lung resections on the da Vinci Surgical Platforms. Currently, the four-arm, look-up-view method, in which the intrathoracic cranial side is viewed from the caudal side, is conside...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966785/ https://www.ncbi.nlm.nih.gov/pubmed/36836464 http://dx.doi.org/10.3390/jpm13020230 |
_version_ | 1784897103165652992 |
---|---|
author | Sakakura, Noriaki Eguchi, Takashi |
author_facet | Sakakura, Noriaki Eguchi, Takashi |
author_sort | Sakakura, Noriaki |
collection | PubMed |
description | This is a narrative review that summarizes the variations in approaches and port placements used for performing robotic lung resections on the da Vinci Surgical Platforms. Currently, the four-arm, look-up-view method, in which the intrathoracic cranial side is viewed from the caudal side, is considered the mainstream approach worldwide. Several variations were devised from this conventional technique, including the so-called horizontal open-thoracotomy-view techniques in which the intrathoracic craniocaudal axis is aligned with the horizontal direction of the console monitor, and fewer port and incision techniques. In September 2022, 166 reports were surveyed using a PubMed English literature search, and this review finally included 30 reports describing the approaches. We categorized the variations into four-phase groups considering advent histories: (I) early era, three-arm technique with utility incisions; (II) four-arm, total port technique without robotic staplers; (III) four-arm technique using robotic staplers; (IV) maximizing the functional features of the Xi, significant alterations in viewing directions, and reducing ports, including the ultimate uniport technique. To comprehensibly visualize these variations for practical use, we created elaborate illustrations based on the literature. The familiarity of thoracic surgeons with the variations and characteristics allows them to choose the optimal procedure that best suits each patient and their preferences. |
format | Online Article Text |
id | pubmed-9966785 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99667852023-02-26 Port Placement Variations for Robotic Lung Resection: Focusing on Their History, Conventional Look-Up-View and Horizontal Open-Thoracotomy-View Techniques, and More Sakakura, Noriaki Eguchi, Takashi J Pers Med Review This is a narrative review that summarizes the variations in approaches and port placements used for performing robotic lung resections on the da Vinci Surgical Platforms. Currently, the four-arm, look-up-view method, in which the intrathoracic cranial side is viewed from the caudal side, is considered the mainstream approach worldwide. Several variations were devised from this conventional technique, including the so-called horizontal open-thoracotomy-view techniques in which the intrathoracic craniocaudal axis is aligned with the horizontal direction of the console monitor, and fewer port and incision techniques. In September 2022, 166 reports were surveyed using a PubMed English literature search, and this review finally included 30 reports describing the approaches. We categorized the variations into four-phase groups considering advent histories: (I) early era, three-arm technique with utility incisions; (II) four-arm, total port technique without robotic staplers; (III) four-arm technique using robotic staplers; (IV) maximizing the functional features of the Xi, significant alterations in viewing directions, and reducing ports, including the ultimate uniport technique. To comprehensibly visualize these variations for practical use, we created elaborate illustrations based on the literature. The familiarity of thoracic surgeons with the variations and characteristics allows them to choose the optimal procedure that best suits each patient and their preferences. MDPI 2023-01-27 /pmc/articles/PMC9966785/ /pubmed/36836464 http://dx.doi.org/10.3390/jpm13020230 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Sakakura, Noriaki Eguchi, Takashi Port Placement Variations for Robotic Lung Resection: Focusing on Their History, Conventional Look-Up-View and Horizontal Open-Thoracotomy-View Techniques, and More |
title | Port Placement Variations for Robotic Lung Resection: Focusing on Their History, Conventional Look-Up-View and Horizontal Open-Thoracotomy-View Techniques, and More |
title_full | Port Placement Variations for Robotic Lung Resection: Focusing on Their History, Conventional Look-Up-View and Horizontal Open-Thoracotomy-View Techniques, and More |
title_fullStr | Port Placement Variations for Robotic Lung Resection: Focusing on Their History, Conventional Look-Up-View and Horizontal Open-Thoracotomy-View Techniques, and More |
title_full_unstemmed | Port Placement Variations for Robotic Lung Resection: Focusing on Their History, Conventional Look-Up-View and Horizontal Open-Thoracotomy-View Techniques, and More |
title_short | Port Placement Variations for Robotic Lung Resection: Focusing on Their History, Conventional Look-Up-View and Horizontal Open-Thoracotomy-View Techniques, and More |
title_sort | port placement variations for robotic lung resection: focusing on their history, conventional look-up-view and horizontal open-thoracotomy-view techniques, and more |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9966785/ https://www.ncbi.nlm.nih.gov/pubmed/36836464 http://dx.doi.org/10.3390/jpm13020230 |
work_keys_str_mv | AT sakakuranoriaki portplacementvariationsforroboticlungresectionfocusingontheirhistoryconventionallookupviewandhorizontalopenthoracotomyviewtechniquesandmore AT eguchitakashi portplacementvariationsforroboticlungresectionfocusingontheirhistoryconventionallookupviewandhorizontalopenthoracotomyviewtechniquesandmore |