Cargando…

Influence of Cathode Channel Parameters and Fan Duty Ratio on Low Power Forced-Convection Open-Cathode Proton Exchange Membrane Fuel Cell Stack

The open-cathode forced-convection proton exchange membrane fuel cell has emerged as a viable option for portable energy sources. The forced-convection open-cathode mode, however, makes the cell’s performance sensitive to changes in the cathode channel and fan parameters. In this study, small fuel c...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Jiaxu, Deng, Huichao, Xue, Rui, Zhang, Yufeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967076/
https://www.ncbi.nlm.nih.gov/pubmed/36837987
http://dx.doi.org/10.3390/mi14020286
_version_ 1784897175132569600
author Zhou, Jiaxu
Deng, Huichao
Xue, Rui
Zhang, Yufeng
author_facet Zhou, Jiaxu
Deng, Huichao
Xue, Rui
Zhang, Yufeng
author_sort Zhou, Jiaxu
collection PubMed
description The open-cathode forced-convection proton exchange membrane fuel cell has emerged as a viable option for portable energy sources. The forced-convection open-cathode mode, however, makes the cell’s performance sensitive to changes in the cathode channel and fan parameters. In this study, small fuel cell stacks with varying cathode channel depths, widths, and width–rib ratios were assembled, and the effects of different cathode channel parameters and fan duty ratios on cell performance were investigated. The experimental results show that changing the cathode channel parameters has a significant impact on oxidant supply. When the channel width is increased, the cell performance increases first, then decreases. The cell performance decreases as the channel width–rib ratio increases. The performance of the cell improves as the cathode channel depth increases. Furthermore, the experimental results show that decreasing the duty ratio of the fan and using moderate heating improves cell performance.
format Online
Article
Text
id pubmed-9967076
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99670762023-02-26 Influence of Cathode Channel Parameters and Fan Duty Ratio on Low Power Forced-Convection Open-Cathode Proton Exchange Membrane Fuel Cell Stack Zhou, Jiaxu Deng, Huichao Xue, Rui Zhang, Yufeng Micromachines (Basel) Article The open-cathode forced-convection proton exchange membrane fuel cell has emerged as a viable option for portable energy sources. The forced-convection open-cathode mode, however, makes the cell’s performance sensitive to changes in the cathode channel and fan parameters. In this study, small fuel cell stacks with varying cathode channel depths, widths, and width–rib ratios were assembled, and the effects of different cathode channel parameters and fan duty ratios on cell performance were investigated. The experimental results show that changing the cathode channel parameters has a significant impact on oxidant supply. When the channel width is increased, the cell performance increases first, then decreases. The cell performance decreases as the channel width–rib ratio increases. The performance of the cell improves as the cathode channel depth increases. Furthermore, the experimental results show that decreasing the duty ratio of the fan and using moderate heating improves cell performance. MDPI 2023-01-22 /pmc/articles/PMC9967076/ /pubmed/36837987 http://dx.doi.org/10.3390/mi14020286 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhou, Jiaxu
Deng, Huichao
Xue, Rui
Zhang, Yufeng
Influence of Cathode Channel Parameters and Fan Duty Ratio on Low Power Forced-Convection Open-Cathode Proton Exchange Membrane Fuel Cell Stack
title Influence of Cathode Channel Parameters and Fan Duty Ratio on Low Power Forced-Convection Open-Cathode Proton Exchange Membrane Fuel Cell Stack
title_full Influence of Cathode Channel Parameters and Fan Duty Ratio on Low Power Forced-Convection Open-Cathode Proton Exchange Membrane Fuel Cell Stack
title_fullStr Influence of Cathode Channel Parameters and Fan Duty Ratio on Low Power Forced-Convection Open-Cathode Proton Exchange Membrane Fuel Cell Stack
title_full_unstemmed Influence of Cathode Channel Parameters and Fan Duty Ratio on Low Power Forced-Convection Open-Cathode Proton Exchange Membrane Fuel Cell Stack
title_short Influence of Cathode Channel Parameters and Fan Duty Ratio on Low Power Forced-Convection Open-Cathode Proton Exchange Membrane Fuel Cell Stack
title_sort influence of cathode channel parameters and fan duty ratio on low power forced-convection open-cathode proton exchange membrane fuel cell stack
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967076/
https://www.ncbi.nlm.nih.gov/pubmed/36837987
http://dx.doi.org/10.3390/mi14020286
work_keys_str_mv AT zhoujiaxu influenceofcathodechannelparametersandfandutyratioonlowpowerforcedconvectionopencathodeprotonexchangemembranefuelcellstack
AT denghuichao influenceofcathodechannelparametersandfandutyratioonlowpowerforcedconvectionopencathodeprotonexchangemembranefuelcellstack
AT xuerui influenceofcathodechannelparametersandfandutyratioonlowpowerforcedconvectionopencathodeprotonexchangemembranefuelcellstack
AT zhangyufeng influenceofcathodechannelparametersandfandutyratioonlowpowerforcedconvectionopencathodeprotonexchangemembranefuelcellstack