Cargando…
Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage
Background and Objectives: To prevent postoperative problems in extreme lateral interbody fusion (XLIF), it is critical that the vertebral endplate not be injured. Unintentional endplate injuries may depend on the cage. A novel porous titanium cage for XLIF has improved geometry with a tapered tip a...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967078/ https://www.ncbi.nlm.nih.gov/pubmed/36837573 http://dx.doi.org/10.3390/medicina59020372 |
_version_ | 1784897175702994944 |
---|---|
author | Segi, Naoki Nakashima, Hiroaki Shinjo, Ryuichi Kagami, Yujiro Machino, Masaaki Ito, Sadayuki Ouchida, Jun Morishita, Kazuaki Oishi, Ryotaro Yamauchi, Ippei Imagama, Shiro |
author_facet | Segi, Naoki Nakashima, Hiroaki Shinjo, Ryuichi Kagami, Yujiro Machino, Masaaki Ito, Sadayuki Ouchida, Jun Morishita, Kazuaki Oishi, Ryotaro Yamauchi, Ippei Imagama, Shiro |
author_sort | Segi, Naoki |
collection | PubMed |
description | Background and Objectives: To prevent postoperative problems in extreme lateral interbody fusion (XLIF), it is critical that the vertebral endplate not be injured. Unintentional endplate injuries may depend on the cage. A novel porous titanium cage for XLIF has improved geometry with a tapered tip and smooth surface. We hypothesized that this new cage should lead to fewer endplate injuries. Materials and Methods: This retrospective study included 32 patients (mean 74.1 ± 6.7 years, 22 females) who underwent anterior and posterior combined surgery with XLIF for lumbar degenerative disease or adult spinal deformity from January 2018 to June 2022. A tapered 3D porous titanium cage (3DTi; 11 patients) and a squared PEEK cage (sPEEK; 21 patients) were used. Spinal alignment values were measured on X-ray images. Vertebral endplate concavity (VEC) was defined as concavity ≥ 1 mm of the endplate on computed tomography (CT) images, which were evaluated preoperatively and at 1 week and 3 months postoperatively. Results: There were no significant differences in the patient demographic data and preoperative and 3-month postoperative spinal alignments between the groups. A 3DTi was used for 25 levels and an sPEEK was used for 38 levels. Preoperative local lordotic angles were 4.3° for 3DTi vs. 4.7° for sPEEK (p = 0.90), which were corrected to 12.3° and 9.1° (p = 0.029), respectively. At 3 months postoperatively, the angles were 11.6° for 3DTi and 8.2° for sPEEK (p = 0.013). VEC was present in 2 levels (8.0%) for 3DTi vs. 17 levels (45%) for sPEEK (p = 0.002). After 3 months postoperatively, none of the 3DTi had VEC progression; however, eight (21%) levels in sPEEK showed VEC progression (p = 0.019). Conclusions: The novel 3DTi cage reduced endplate injuries by reducing the endplate load during cage insertion. |
format | Online Article Text |
id | pubmed-9967078 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99670782023-02-26 Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage Segi, Naoki Nakashima, Hiroaki Shinjo, Ryuichi Kagami, Yujiro Machino, Masaaki Ito, Sadayuki Ouchida, Jun Morishita, Kazuaki Oishi, Ryotaro Yamauchi, Ippei Imagama, Shiro Medicina (Kaunas) Article Background and Objectives: To prevent postoperative problems in extreme lateral interbody fusion (XLIF), it is critical that the vertebral endplate not be injured. Unintentional endplate injuries may depend on the cage. A novel porous titanium cage for XLIF has improved geometry with a tapered tip and smooth surface. We hypothesized that this new cage should lead to fewer endplate injuries. Materials and Methods: This retrospective study included 32 patients (mean 74.1 ± 6.7 years, 22 females) who underwent anterior and posterior combined surgery with XLIF for lumbar degenerative disease or adult spinal deformity from January 2018 to June 2022. A tapered 3D porous titanium cage (3DTi; 11 patients) and a squared PEEK cage (sPEEK; 21 patients) were used. Spinal alignment values were measured on X-ray images. Vertebral endplate concavity (VEC) was defined as concavity ≥ 1 mm of the endplate on computed tomography (CT) images, which were evaluated preoperatively and at 1 week and 3 months postoperatively. Results: There were no significant differences in the patient demographic data and preoperative and 3-month postoperative spinal alignments between the groups. A 3DTi was used for 25 levels and an sPEEK was used for 38 levels. Preoperative local lordotic angles were 4.3° for 3DTi vs. 4.7° for sPEEK (p = 0.90), which were corrected to 12.3° and 9.1° (p = 0.029), respectively. At 3 months postoperatively, the angles were 11.6° for 3DTi and 8.2° for sPEEK (p = 0.013). VEC was present in 2 levels (8.0%) for 3DTi vs. 17 levels (45%) for sPEEK (p = 0.002). After 3 months postoperatively, none of the 3DTi had VEC progression; however, eight (21%) levels in sPEEK showed VEC progression (p = 0.019). Conclusions: The novel 3DTi cage reduced endplate injuries by reducing the endplate load during cage insertion. MDPI 2023-02-15 /pmc/articles/PMC9967078/ /pubmed/36837573 http://dx.doi.org/10.3390/medicina59020372 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Segi, Naoki Nakashima, Hiroaki Shinjo, Ryuichi Kagami, Yujiro Machino, Masaaki Ito, Sadayuki Ouchida, Jun Morishita, Kazuaki Oishi, Ryotaro Yamauchi, Ippei Imagama, Shiro Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage |
title | Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage |
title_full | Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage |
title_fullStr | Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage |
title_full_unstemmed | Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage |
title_short | Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage |
title_sort | vertebral endplate concavity in lateral lumbar interbody fusion: tapered 3d-printed porous titanium cage versus squared peek cage |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967078/ https://www.ncbi.nlm.nih.gov/pubmed/36837573 http://dx.doi.org/10.3390/medicina59020372 |
work_keys_str_mv | AT seginaoki vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT nakashimahiroaki vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT shinjoryuichi vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT kagamiyujiro vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT machinomasaaki vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT itosadayuki vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT ouchidajun vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT morishitakazuaki vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT oishiryotaro vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT yamauchiippei vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage AT imagamashiro vertebralendplateconcavityinlaterallumbarinterbodyfusiontapered3dprintedporoustitaniumcageversussquaredpeekcage |