Peri-implantitis is an inflammatory disease similar to periodontitis, caused by biofilms formed on the surface of dental implants. This inflammation can spread to bone tissues and result in bone loss. Therefore, it is essential to inhibit the formation of biofilms on the surface of dental implants....

Descripción completa

Detalles Bibliográficos
Autores principales: Ji, Min-Kyung, Lee, Seon-Ki, Kim, Hee-Seon, Oh, Gye-Jeong, Cho, Hoonsung, Lim, Hyun-Pil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967395/
https://www.ncbi.nlm.nih.gov/pubmed/36834746
http://dx.doi.org/10.3390/ijms24043335
_version_ 1784897253641551872
author Ji, Min-Kyung
Lee, Seon-Ki
Kim, Hee-Seon
Oh, Gye-Jeong
Cho, Hoonsung
Lim, Hyun-Pil
author_facet Ji, Min-Kyung
Lee, Seon-Ki
Kim, Hee-Seon
Oh, Gye-Jeong
Cho, Hoonsung
Lim, Hyun-Pil
author_sort Ji, Min-Kyung
collection PubMed
description Peri-implantitis is an inflammatory disease similar to periodontitis, caused by biofilms formed on the surface of dental implants. This inflammation can spread to bone tissues and result in bone loss. Therefore, it is essential to inhibit the formation of biofilms on the surface of dental implants. Thus, this study examined the inhibition of biofilm formation by treating TiO(2) nanotubes with heat and plasma. Commercially pure titanium specimens were anodized to form TiO(2) nanotubes. Heat treatment was performed at 400 and 600 °C, and atmospheric pressure plasma was applied using a plasma generator (PGS-200, Expantech, Suwon, Republic of Korea). Contact angles, surface roughness, surface structure, crystal structure, and chemical compositions were measured to analyze the surface properties of the specimens. The inhibition of biofilm formation was assessed using two methods. The results of this study showed that the heat treatment of TiO(2) nanotubes at 400 °C inhibited the adhesion of Streptococcus mutans (S. mutans), associated with initial biofilm formation, and that heat treatment of TiO(2) nanotubes at 600 °C inhibited the adhesion of Porphyromonas gingivalis (P. gingivalis), which causes peri-implantitis. Applying plasma to the TiO(2) nanotubes heat-treated at 600 °C inhibited the adhesion of S. mutans and P. gingivalis.
format Online
Article
Text
id pubmed-9967395
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99673952023-02-26 Assessment of Inhibition of Biofilm Formation on Non-Thermal Plasma-Treated TiO(2) Nanotubes Ji, Min-Kyung Lee, Seon-Ki Kim, Hee-Seon Oh, Gye-Jeong Cho, Hoonsung Lim, Hyun-Pil Int J Mol Sci Article Peri-implantitis is an inflammatory disease similar to periodontitis, caused by biofilms formed on the surface of dental implants. This inflammation can spread to bone tissues and result in bone loss. Therefore, it is essential to inhibit the formation of biofilms on the surface of dental implants. Thus, this study examined the inhibition of biofilm formation by treating TiO(2) nanotubes with heat and plasma. Commercially pure titanium specimens were anodized to form TiO(2) nanotubes. Heat treatment was performed at 400 and 600 °C, and atmospheric pressure plasma was applied using a plasma generator (PGS-200, Expantech, Suwon, Republic of Korea). Contact angles, surface roughness, surface structure, crystal structure, and chemical compositions were measured to analyze the surface properties of the specimens. The inhibition of biofilm formation was assessed using two methods. The results of this study showed that the heat treatment of TiO(2) nanotubes at 400 °C inhibited the adhesion of Streptococcus mutans (S. mutans), associated with initial biofilm formation, and that heat treatment of TiO(2) nanotubes at 600 °C inhibited the adhesion of Porphyromonas gingivalis (P. gingivalis), which causes peri-implantitis. Applying plasma to the TiO(2) nanotubes heat-treated at 600 °C inhibited the adhesion of S. mutans and P. gingivalis. MDPI 2023-02-07 /pmc/articles/PMC9967395/ /pubmed/36834746 http://dx.doi.org/10.3390/ijms24043335 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ji, Min-Kyung
Lee, Seon-Ki
Kim, Hee-Seon
Oh, Gye-Jeong
Cho, Hoonsung
Lim, Hyun-Pil
Assessment of Inhibition of Biofilm Formation on Non-Thermal Plasma-Treated TiO(2) Nanotubes
title Assessment of Inhibition of Biofilm Formation on Non-Thermal Plasma-Treated TiO(2) Nanotubes
title_full Assessment of Inhibition of Biofilm Formation on Non-Thermal Plasma-Treated TiO(2) Nanotubes
title_fullStr Assessment of Inhibition of Biofilm Formation on Non-Thermal Plasma-Treated TiO(2) Nanotubes
title_full_unstemmed Assessment of Inhibition of Biofilm Formation on Non-Thermal Plasma-Treated TiO(2) Nanotubes
title_short Assessment of Inhibition of Biofilm Formation on Non-Thermal Plasma-Treated TiO(2) Nanotubes
title_sort assessment of inhibition of biofilm formation on non-thermal plasma-treated tio(2) nanotubes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967395/
https://www.ncbi.nlm.nih.gov/pubmed/36834746
http://dx.doi.org/10.3390/ijms24043335
work_keys_str_mv AT jiminkyung assessmentofinhibitionofbiofilmformationonnonthermalplasmatreatedtio2nanotubes
AT leeseonki assessmentofinhibitionofbiofilmformationonnonthermalplasmatreatedtio2nanotubes
AT kimheeseon assessmentofinhibitionofbiofilmformationonnonthermalplasmatreatedtio2nanotubes
AT ohgyejeong assessmentofinhibitionofbiofilmformationonnonthermalplasmatreatedtio2nanotubes
AT chohoonsung assessmentofinhibitionofbiofilmformationonnonthermalplasmatreatedtio2nanotubes
AT limhyunpil assessmentofinhibitionofbiofilmformationonnonthermalplasmatreatedtio2nanotubes