Quantification of Comfort for the Development of Binding Parts in a Standing Rehabilitation Robot

Human-machine interfaces (HMI) refer to the physical interaction between a user and rehabilitation robots. A persisting excessive load leads to soft tissue damage, such as pressure ulcers. Therefore, it is necessary to define a comfortable binding part for a rehabilitation robot with the subject in...

Descripción completa

Detalles Bibliográficos
Autores principales: Nam, Yejin, Yang, Sumin, Kim, Jongman, Koo, Bummo, Song, Sunghyuk, Kim, Youngho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967481/
https://www.ncbi.nlm.nih.gov/pubmed/36850804
http://dx.doi.org/10.3390/s23042206
_version_ 1784897275346026496
author Nam, Yejin
Yang, Sumin
Kim, Jongman
Koo, Bummo
Song, Sunghyuk
Kim, Youngho
author_facet Nam, Yejin
Yang, Sumin
Kim, Jongman
Koo, Bummo
Song, Sunghyuk
Kim, Youngho
author_sort Nam, Yejin
collection PubMed
description Human-machine interfaces (HMI) refer to the physical interaction between a user and rehabilitation robots. A persisting excessive load leads to soft tissue damage, such as pressure ulcers. Therefore, it is necessary to define a comfortable binding part for a rehabilitation robot with the subject in a standing posture. The purpose of this study was to quantify the comfort at the binding parts of the standing rehabilitation robot. In Experiment 1, cuff pressures of 10–40 kPa were applied to the thigh, shank, and knee of standing subjects, and the interface pressure and pain scale were obtained. In Experiment 2, cuff pressures of 10–20 kPa were applied to the thigh, and the tissue oxygen saturation and the skin temperature were measured. Questionnaire responses regarding comfort during compression were obtained from the subjects using the visual analog scale and the Likert scale. The greatest pain was perceived in the thigh. The musculoskeletal configuration affected the pressure distribution. The interface pressure distribution by the binding part showed higher pressure at the intermuscular septum. Tissue oxygen saturation (StO(2)) increased to 111.9 ± 6.7% when a cuff pressure of 10 kPa was applied and decreased to 92.2 ± 16.9% for a cuff pressure of 20 kPa. A skin temperature variation greater than 0.2 °C occurred in the compressed leg. These findings would help evaluate and improve the comfort of rehabilitation robots.
format Online
Article
Text
id pubmed-9967481
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99674812023-02-27 Quantification of Comfort for the Development of Binding Parts in a Standing Rehabilitation Robot Nam, Yejin Yang, Sumin Kim, Jongman Koo, Bummo Song, Sunghyuk Kim, Youngho Sensors (Basel) Article Human-machine interfaces (HMI) refer to the physical interaction between a user and rehabilitation robots. A persisting excessive load leads to soft tissue damage, such as pressure ulcers. Therefore, it is necessary to define a comfortable binding part for a rehabilitation robot with the subject in a standing posture. The purpose of this study was to quantify the comfort at the binding parts of the standing rehabilitation robot. In Experiment 1, cuff pressures of 10–40 kPa were applied to the thigh, shank, and knee of standing subjects, and the interface pressure and pain scale were obtained. In Experiment 2, cuff pressures of 10–20 kPa were applied to the thigh, and the tissue oxygen saturation and the skin temperature were measured. Questionnaire responses regarding comfort during compression were obtained from the subjects using the visual analog scale and the Likert scale. The greatest pain was perceived in the thigh. The musculoskeletal configuration affected the pressure distribution. The interface pressure distribution by the binding part showed higher pressure at the intermuscular septum. Tissue oxygen saturation (StO(2)) increased to 111.9 ± 6.7% when a cuff pressure of 10 kPa was applied and decreased to 92.2 ± 16.9% for a cuff pressure of 20 kPa. A skin temperature variation greater than 0.2 °C occurred in the compressed leg. These findings would help evaluate and improve the comfort of rehabilitation robots. MDPI 2023-02-16 /pmc/articles/PMC9967481/ /pubmed/36850804 http://dx.doi.org/10.3390/s23042206 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nam, Yejin
Yang, Sumin
Kim, Jongman
Koo, Bummo
Song, Sunghyuk
Kim, Youngho
Quantification of Comfort for the Development of Binding Parts in a Standing Rehabilitation Robot
title Quantification of Comfort for the Development of Binding Parts in a Standing Rehabilitation Robot
title_full Quantification of Comfort for the Development of Binding Parts in a Standing Rehabilitation Robot
title_fullStr Quantification of Comfort for the Development of Binding Parts in a Standing Rehabilitation Robot
title_full_unstemmed Quantification of Comfort for the Development of Binding Parts in a Standing Rehabilitation Robot
title_short Quantification of Comfort for the Development of Binding Parts in a Standing Rehabilitation Robot
title_sort quantification of comfort for the development of binding parts in a standing rehabilitation robot
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967481/
https://www.ncbi.nlm.nih.gov/pubmed/36850804
http://dx.doi.org/10.3390/s23042206
work_keys_str_mv AT namyejin quantificationofcomfortforthedevelopmentofbindingpartsinastandingrehabilitationrobot
AT yangsumin quantificationofcomfortforthedevelopmentofbindingpartsinastandingrehabilitationrobot
AT kimjongman quantificationofcomfortforthedevelopmentofbindingpartsinastandingrehabilitationrobot
AT koobummo quantificationofcomfortforthedevelopmentofbindingpartsinastandingrehabilitationrobot
AT songsunghyuk quantificationofcomfortforthedevelopmentofbindingpartsinastandingrehabilitationrobot
AT kimyoungho quantificationofcomfortforthedevelopmentofbindingpartsinastandingrehabilitationrobot