Cargando…

Smart Cup for In-Situ 3D Measurement of Wall-Mounted Debris via 2D Sensing Grid in Production Pipelines

The accumulation of separated out impurities from pipeline transported medium onto the pipe wall is a major cause of downtime maintenance of oil and gas production systems. To regularly scrub off wall-mounted debris and probe the severity, pipeline inspection gauges (PIG) are the state-of-the-art to...

Descripción completa

Detalles Bibliográficos
Autores principales: Tian, Hao, Wang, Sunyi, Fu, Minglei, Ning, Dayong, Gong, Yongjun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967792/
https://www.ncbi.nlm.nih.gov/pubmed/36838189
http://dx.doi.org/10.3390/mi14020489
_version_ 1784897353526804480
author Tian, Hao
Wang, Sunyi
Fu, Minglei
Ning, Dayong
Gong, Yongjun
author_facet Tian, Hao
Wang, Sunyi
Fu, Minglei
Ning, Dayong
Gong, Yongjun
author_sort Tian, Hao
collection PubMed
description The accumulation of separated out impurities from pipeline transported medium onto the pipe wall is a major cause of downtime maintenance of oil and gas production systems. To regularly scrub off wall-mounted debris and probe the severity, pipeline inspection gauges (PIG) are the state-of-the-art tools developed for the task, using the pressure differential across the device as the driving force, and tag-along sensing equipment for wall defects measurement. Currently, the PIG propulsion and sensing tasks are realized by separate compartments, limited to large diameter operations. In this work, a soft solution for medium to small diameter pipelines has been demonstrated. The smart cup with integrated sensing grid is proposed to achieve integrated wall-mounted debris dimensional measurement, without the need of additional sensors. To achieve the goal, this work starts from the mathematical modelling of the geometric problem, to new fabrication procedures, experimental setup, and finally finishes with validation results. Initial results have shown that using the proposed smart cup, the wall-mounted debris can be detected, with modelling error maxed at 5.1%, and deformation detection accuracy between 1.18% and 1.92% with respect to the outer diameter.
format Online
Article
Text
id pubmed-9967792
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99677922023-02-27 Smart Cup for In-Situ 3D Measurement of Wall-Mounted Debris via 2D Sensing Grid in Production Pipelines Tian, Hao Wang, Sunyi Fu, Minglei Ning, Dayong Gong, Yongjun Micromachines (Basel) Article The accumulation of separated out impurities from pipeline transported medium onto the pipe wall is a major cause of downtime maintenance of oil and gas production systems. To regularly scrub off wall-mounted debris and probe the severity, pipeline inspection gauges (PIG) are the state-of-the-art tools developed for the task, using the pressure differential across the device as the driving force, and tag-along sensing equipment for wall defects measurement. Currently, the PIG propulsion and sensing tasks are realized by separate compartments, limited to large diameter operations. In this work, a soft solution for medium to small diameter pipelines has been demonstrated. The smart cup with integrated sensing grid is proposed to achieve integrated wall-mounted debris dimensional measurement, without the need of additional sensors. To achieve the goal, this work starts from the mathematical modelling of the geometric problem, to new fabrication procedures, experimental setup, and finally finishes with validation results. Initial results have shown that using the proposed smart cup, the wall-mounted debris can be detected, with modelling error maxed at 5.1%, and deformation detection accuracy between 1.18% and 1.92% with respect to the outer diameter. MDPI 2023-02-19 /pmc/articles/PMC9967792/ /pubmed/36838189 http://dx.doi.org/10.3390/mi14020489 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tian, Hao
Wang, Sunyi
Fu, Minglei
Ning, Dayong
Gong, Yongjun
Smart Cup for In-Situ 3D Measurement of Wall-Mounted Debris via 2D Sensing Grid in Production Pipelines
title Smart Cup for In-Situ 3D Measurement of Wall-Mounted Debris via 2D Sensing Grid in Production Pipelines
title_full Smart Cup for In-Situ 3D Measurement of Wall-Mounted Debris via 2D Sensing Grid in Production Pipelines
title_fullStr Smart Cup for In-Situ 3D Measurement of Wall-Mounted Debris via 2D Sensing Grid in Production Pipelines
title_full_unstemmed Smart Cup for In-Situ 3D Measurement of Wall-Mounted Debris via 2D Sensing Grid in Production Pipelines
title_short Smart Cup for In-Situ 3D Measurement of Wall-Mounted Debris via 2D Sensing Grid in Production Pipelines
title_sort smart cup for in-situ 3d measurement of wall-mounted debris via 2d sensing grid in production pipelines
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967792/
https://www.ncbi.nlm.nih.gov/pubmed/36838189
http://dx.doi.org/10.3390/mi14020489
work_keys_str_mv AT tianhao smartcupforinsitu3dmeasurementofwallmounteddebrisvia2dsensinggridinproductionpipelines
AT wangsunyi smartcupforinsitu3dmeasurementofwallmounteddebrisvia2dsensinggridinproductionpipelines
AT fuminglei smartcupforinsitu3dmeasurementofwallmounteddebrisvia2dsensinggridinproductionpipelines
AT ningdayong smartcupforinsitu3dmeasurementofwallmounteddebrisvia2dsensinggridinproductionpipelines
AT gongyongjun smartcupforinsitu3dmeasurementofwallmounteddebrisvia2dsensinggridinproductionpipelines