Cargando…

Right ventricular outflow tract stenting promotes pulmonary artery development in tetralogy of fallot

BACKGROUND: Right ventricular outflow tract (RVOT) stenting seems to be suggested as a promising treatment option and an alternative to modified Blalock-Taussig shunt (mBTS) in the initial palliation of patients with Fallot-type lesions in recent years. This study sought to assess the effect of RVOT...

Descripción completa

Detalles Bibliográficos
Autores principales: Guo, Hui, Wu, Zhongshi, Zhao, Tianli, Yang, Jinfu, Hu, Shijun, Huang, Can, Yang, Yifeng, Xie, Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9968738/
https://www.ncbi.nlm.nih.gov/pubmed/36860944
http://dx.doi.org/10.3389/fsurg.2023.1056772
Descripción
Sumario:BACKGROUND: Right ventricular outflow tract (RVOT) stenting seems to be suggested as a promising treatment option and an alternative to modified Blalock-Taussig shunt (mBTS) in the initial palliation of patients with Fallot-type lesions in recent years. This study sought to assess the effect of RVOT stenting on the growth of the pulmonary artery (PA) in patients with Tetralogy of Fallot (TOF). METHODS: Retrospective review analyzing 5 patients with Fallot-type congenital heart disease with small pulmonary arteries who underwent palliative with RVOT stenting and 9 patients underwent modified Blalock-Taussig shunt within 9 years period. Differential left PA (LPA) and right PA (RPA) growth was measured by Cardiovascular Computed Tomography Angiography (CTA). RESULTS: RVOT stenting improved arterial oxygen saturation from median of 60% (interquartile range [IQR]: 37% to 79%) to 95% (87.5% to 97.5%) (p = 0.028). The LPA diameter Z-score improved from −2.843 (−3.51–2.037) to −0.78 (−2.3305–0.19) (p = 0.03), the RPA diameter Z-score improved from median −2.843 (−3.51–2.037) to −0.477 (−1.1145–0.459) (p = 0.002), the Mc Goon ratio increased from median 1 (0.8–1.105) to 1.32 (1.25–1.98) (p = 0.017). There were no procedural complications and all 5 patients have undergone final repair in the RVOT stent group. In the mBTS group, the LPA diameter Z-score improved from −1.494 (−2.242–0.6135) to −0.396 (−1.488–1.228) (p = 0.15), the RPA diameter Z-score improved from median −1.328 (−2.036–0.838) to 0.088 (−0.486–1.223) (p = 0.007), and there were 5 patients occur different complications and 4 patients was not attained the standards of final surgical repair. CONCLUSION: RVOT stenting, compared with mBTS, seems to better promote pulmonary artery growth, improve arterial oxygen saturations, and have less procedure complications in patients with TOF who being absolute contraindicated for primary repair due to high risks.