Intrasession repeatability and agreement of a new method to measure the foveal fixation axis

PURPOSE: Ophthalmic lens adaptation, particularly with progressive addition lenses, requires accurate measurements of the patient nasopupillary distance (NPD) and interpupillary distance (IPD), which are usually collected using the pupil centre as a reference. However, differences between the pupil...

Descripción completa

Detalles Bibliográficos
Autores principales: Garcia Espinilla, Oscar, Sanchez, Irene, Martin, Raul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9969851/
https://www.ncbi.nlm.nih.gov/pubmed/36860763
http://dx.doi.org/10.7717/peerj.14942
_version_ 1784897809031364608
author Garcia Espinilla, Oscar
Sanchez, Irene
Martin, Raul
author_facet Garcia Espinilla, Oscar
Sanchez, Irene
Martin, Raul
author_sort Garcia Espinilla, Oscar
collection PubMed
description PURPOSE: Ophthalmic lens adaptation, particularly with progressive addition lenses, requires accurate measurements of the patient nasopupillary distance (NPD) and interpupillary distance (IPD), which are usually collected using the pupil centre as a reference. However, differences between the pupil centre and visual or foveal axis could induce some subsidiary effects of correcting lenses. This study aimed to assess the intrasession repeatability of a new prototype (Ergofocus®; Lentitech, Barakaldo, Spain) that can measure the foveal fixation axis (FFA) distance and assess the agreement with the NPD measurements collected using a traditional method (frame ruler). METHODS: The FFA at far and near distances was measured three consecutive times in 39 healthy volunteers to determine the intrasession repeatability according to the British Standards Institute and International Organization for Standardization. Additionally, the FFA and NPD (standard frame ruler) were measured in 71 healthy volunteers and compared using Bland–Altman analysis. Two blinded experienced practitioners conducted each FFA and NPD measurement. RESULTS: The FFA measurements showed acceptable repeatability at far distances (right eye (RE): Sw = 1.16 ± 0.76 mm and coefficient of variation (CV) = 3.92 ± 2.51%; left eye (LE) Sw = 1.11 ± 0.79 mm and CV = 3.76 ± 2.51%) and at near distances (RE: Sw = 0.97 ± 0.85 mm and CV = 3.52 ± 3.02%; LE: Sw = 1.17 ± 0.96 mm and CV = 4.54 ± 3.72%). Additionally, agreement with the NPD showed large differences at far distances (RE: −2.15 ± 2.34, LoA = −6.73 to 2.43 mm (P < 0.001); LE: −0.61 ± 2.62, LoA = −5.75 to 4.53 mm (P = 0.052)) and near distances (RE: −3.08 ± 2.80, LoA −8.57 to 2.42 mm (P < 0.001); LE: −2.97 ± 3.97, LoA: −10.75 to 4.80 mm (P < 0.001)). CONCLUSIONS: FFA measurements showed clinically acceptable repeatability at both far and near distances. Agreement with the NPD measured using a standard frame ruler showed significant differences, suggesting that both measurements are not interchangeable in clinical practice to prescribe and center ophthalmic lenses. Further research is necessary to assess the impact of FFA measurement in ophthalmic lens prescriptions.
format Online
Article
Text
id pubmed-9969851
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-99698512023-02-28 Intrasession repeatability and agreement of a new method to measure the foveal fixation axis Garcia Espinilla, Oscar Sanchez, Irene Martin, Raul PeerJ Anatomy and Physiology PURPOSE: Ophthalmic lens adaptation, particularly with progressive addition lenses, requires accurate measurements of the patient nasopupillary distance (NPD) and interpupillary distance (IPD), which are usually collected using the pupil centre as a reference. However, differences between the pupil centre and visual or foveal axis could induce some subsidiary effects of correcting lenses. This study aimed to assess the intrasession repeatability of a new prototype (Ergofocus®; Lentitech, Barakaldo, Spain) that can measure the foveal fixation axis (FFA) distance and assess the agreement with the NPD measurements collected using a traditional method (frame ruler). METHODS: The FFA at far and near distances was measured three consecutive times in 39 healthy volunteers to determine the intrasession repeatability according to the British Standards Institute and International Organization for Standardization. Additionally, the FFA and NPD (standard frame ruler) were measured in 71 healthy volunteers and compared using Bland–Altman analysis. Two blinded experienced practitioners conducted each FFA and NPD measurement. RESULTS: The FFA measurements showed acceptable repeatability at far distances (right eye (RE): Sw = 1.16 ± 0.76 mm and coefficient of variation (CV) = 3.92 ± 2.51%; left eye (LE) Sw = 1.11 ± 0.79 mm and CV = 3.76 ± 2.51%) and at near distances (RE: Sw = 0.97 ± 0.85 mm and CV = 3.52 ± 3.02%; LE: Sw = 1.17 ± 0.96 mm and CV = 4.54 ± 3.72%). Additionally, agreement with the NPD showed large differences at far distances (RE: −2.15 ± 2.34, LoA = −6.73 to 2.43 mm (P < 0.001); LE: −0.61 ± 2.62, LoA = −5.75 to 4.53 mm (P = 0.052)) and near distances (RE: −3.08 ± 2.80, LoA −8.57 to 2.42 mm (P < 0.001); LE: −2.97 ± 3.97, LoA: −10.75 to 4.80 mm (P < 0.001)). CONCLUSIONS: FFA measurements showed clinically acceptable repeatability at both far and near distances. Agreement with the NPD measured using a standard frame ruler showed significant differences, suggesting that both measurements are not interchangeable in clinical practice to prescribe and center ophthalmic lenses. Further research is necessary to assess the impact of FFA measurement in ophthalmic lens prescriptions. PeerJ Inc. 2023-02-24 /pmc/articles/PMC9969851/ /pubmed/36860763 http://dx.doi.org/10.7717/peerj.14942 Text en © 2023 Garcia Espinilla et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited.
spellingShingle Anatomy and Physiology
Garcia Espinilla, Oscar
Sanchez, Irene
Martin, Raul
Intrasession repeatability and agreement of a new method to measure the foveal fixation axis
title Intrasession repeatability and agreement of a new method to measure the foveal fixation axis
title_full Intrasession repeatability and agreement of a new method to measure the foveal fixation axis
title_fullStr Intrasession repeatability and agreement of a new method to measure the foveal fixation axis
title_full_unstemmed Intrasession repeatability and agreement of a new method to measure the foveal fixation axis
title_short Intrasession repeatability and agreement of a new method to measure the foveal fixation axis
title_sort intrasession repeatability and agreement of a new method to measure the foveal fixation axis
topic Anatomy and Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9969851/
https://www.ncbi.nlm.nih.gov/pubmed/36860763
http://dx.doi.org/10.7717/peerj.14942
work_keys_str_mv AT garciaespinillaoscar intrasessionrepeatabilityandagreementofanewmethodtomeasurethefovealfixationaxis
AT sanchezirene intrasessionrepeatabilityandagreementofanewmethodtomeasurethefovealfixationaxis
AT martinraul intrasessionrepeatabilityandagreementofanewmethodtomeasurethefovealfixationaxis