Cargando…
Diagnostic performance of cryobiopsy guided by radial-probe EBUS with a guide sheath for peripheral pulmonary lesions
OBJECTIVE: Transbronchial lung cryobiopsy (TBCB) has developed rapidly and has become one of the research hotspots of lung biopsy technology. The present study sought to evaluate the efficacy of TBCB guided by radial-probe EBUS (RP-EBUS) and a guide sheath (GS) without fluoroscopy for peripheral pul...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Pneumologia e Tisiologia
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970367/ https://www.ncbi.nlm.nih.gov/pubmed/36629733 http://dx.doi.org/10.36416/1806-3756/e20220200 |
Sumario: | OBJECTIVE: Transbronchial lung cryobiopsy (TBCB) has developed rapidly and has become one of the research hotspots of lung biopsy technology. The present study sought to evaluate the efficacy of TBCB guided by radial-probe EBUS (RP-EBUS) and a guide sheath (GS) without fluoroscopy for peripheral pulmonary lesions. METHODS: In this retrospective study, McNemar’s test was used in order to compare TBCB and transbronchial forceps biopsy (TBFB) in terms of diagnostic performance. A multivariate logistic regression model was designed to explore the association between predictive variables and the diagnostic yield of TBCB. RESULTS: A total of 168 patients underwent GS-guided RP-EBUS. Of those, 157 had lesions that were visible and 11 had lesions that were not. Of those 157 patients, 24 were excluded because of missing data or an unclear final diagnosis. Therefore, 133 patients underwent RP-EBUS-GS-guided TBFB and TBCB. The pooled diagnostic yield of RP-EBUS-GS-guided TBCB without fluoroscopy was 71.5% (103/144). In 133 patients, the diagnostic yield of TBCB was significantly higher than that of TBFB (77.4% vs. 59.4%; p < 0.05). Multivariate analysis indicated that lesion size and site were independently associated with the diagnostic yield of TBCB (OR = 2.8, p = 0.03 and OR = 4.1, p = 0.01, respectively), although cryoprobe size was not. There was no significant difference between the 1.1-mm cryoprobe and the 1.9-mm cryoprobe in terms of diagnostic performance (78.4% vs. 76.8%; p > 0.05). CONCLUSIONS: GS-guided RP-EBUS is regarded as a practical option for guiding cryobiopsy, although it may not be able to replace fluoroscopy. Peripheral pulmonary lesions not located in the upper lobes or larger than 30 mm are significantly associated with a higher diagnostic yield of cryobiopsy. |
---|