Cargando…
New screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures
Management of the ischial fragment in acetabular fractures is a considerable problem. In this report, we presented how to drill or screw around the posterior column and ischium from the anterior approach using a novel ‘sleeve guide technique’ and the difficulty of plating. A sleeve, drill, depth gau...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970693/ https://www.ncbi.nlm.nih.gov/pubmed/36860356 http://dx.doi.org/10.1093/jscr/rjad073 |
_version_ | 1784897954682765312 |
---|---|
author | Asanuma, Kunihiro Miyamura, Gaku Suzuki, Yoshiaki Makino, Yoshinori Takada, Naoya Satonaka, Haruhiko Yoshida, Kakunoshin Hagi, Tomohito Nakamura, Tomoki Sudo, Akihiro |
author_facet | Asanuma, Kunihiro Miyamura, Gaku Suzuki, Yoshiaki Makino, Yoshinori Takada, Naoya Satonaka, Haruhiko Yoshida, Kakunoshin Hagi, Tomohito Nakamura, Tomoki Sudo, Akihiro |
author_sort | Asanuma, Kunihiro |
collection | PubMed |
description | Management of the ischial fragment in acetabular fractures is a considerable problem. In this report, we presented how to drill or screw around the posterior column and ischium from the anterior approach using a novel ‘sleeve guide technique’ and the difficulty of plating. A sleeve, drill, depth gauge and driver from DepuySynthes were prepared. The portal was about 2–3 cm inside the anterior superior iliac spine opposite to the side of the fracture. The sleeve was inserted to the screw point around quadrilateral area through the retroperitoneal space. Drilling, measuring screw length by a depth gauge and the screwing were performed through the sleeve. Case 1 used a one-third plate and case 2 used a reconstruction plate. With this technique, the approach angles to the posterior column and ischium were inclined, and plating and screw insertion could be performed with a low risk of organ injury. |
format | Online Article Text |
id | pubmed-9970693 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-99706932023-02-28 New screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures Asanuma, Kunihiro Miyamura, Gaku Suzuki, Yoshiaki Makino, Yoshinori Takada, Naoya Satonaka, Haruhiko Yoshida, Kakunoshin Hagi, Tomohito Nakamura, Tomoki Sudo, Akihiro J Surg Case Rep Case Series Management of the ischial fragment in acetabular fractures is a considerable problem. In this report, we presented how to drill or screw around the posterior column and ischium from the anterior approach using a novel ‘sleeve guide technique’ and the difficulty of plating. A sleeve, drill, depth gauge and driver from DepuySynthes were prepared. The portal was about 2–3 cm inside the anterior superior iliac spine opposite to the side of the fracture. The sleeve was inserted to the screw point around quadrilateral area through the retroperitoneal space. Drilling, measuring screw length by a depth gauge and the screwing were performed through the sleeve. Case 1 used a one-third plate and case 2 used a reconstruction plate. With this technique, the approach angles to the posterior column and ischium were inclined, and plating and screw insertion could be performed with a low risk of organ injury. Oxford University Press 2023-02-27 /pmc/articles/PMC9970693/ /pubmed/36860356 http://dx.doi.org/10.1093/jscr/rjad073 Text en Published by Oxford University Press and JSCR Publishing Ltd. © The Author(s) 2023. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Series Asanuma, Kunihiro Miyamura, Gaku Suzuki, Yoshiaki Makino, Yoshinori Takada, Naoya Satonaka, Haruhiko Yoshida, Kakunoshin Hagi, Tomohito Nakamura, Tomoki Sudo, Akihiro New screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures |
title | New screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures |
title_full | New screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures |
title_fullStr | New screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures |
title_full_unstemmed | New screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures |
title_short | New screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures |
title_sort | new screw technique for posterior column and ischial fixation from the anterior approach for acetabular fractures |
topic | Case Series |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970693/ https://www.ncbi.nlm.nih.gov/pubmed/36860356 http://dx.doi.org/10.1093/jscr/rjad073 |
work_keys_str_mv | AT asanumakunihiro newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT miyamuragaku newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT suzukiyoshiaki newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT makinoyoshinori newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT takadanaoya newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT satonakaharuhiko newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT yoshidakakunoshin newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT hagitomohito newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT nakamuratomoki newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures AT sudoakihiro newscrewtechniqueforposteriorcolumnandischialfixationfromtheanteriorapproachforacetabularfractures |