Cargando…

Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia

To study the application of intraoperative EMG intelligent monitoring in orthopedic surgery under general anesthesia, a total of 53 patients who underwent orthopedic surgery from February 2021 to February 2022 were selected. The combined monitoring of somatosensory evoked potential (SEP), motor evok...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Mingmin, Duan, Junfeng, Chen, Yanchun, Zhang, Chunyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970720/
https://www.ncbi.nlm.nih.gov/pubmed/36860799
http://dx.doi.org/10.1155/2023/1484802
_version_ 1784897960566325248
author Zhang, Mingmin
Duan, Junfeng
Chen, Yanchun
Zhang, Chunyu
author_facet Zhang, Mingmin
Duan, Junfeng
Chen, Yanchun
Zhang, Chunyu
author_sort Zhang, Mingmin
collection PubMed
description To study the application of intraoperative EMG intelligent monitoring in orthopedic surgery under general anesthesia, a total of 53 patients who underwent orthopedic surgery from February 2021 to February 2022 were selected. The combined monitoring of somatosensory evoked potential (SEP), motor evoked potential (MEP), and electromyography (EMG) was used to analyze the monitoring efficiency. In 38 of the 53 patients, the intraoperative signal was normal, and there was no postoperative neurological dysfunction; one case had abnormal signal, and the abnormality still existed after debugging, but no obvious neurological dysfunction was found after operation; the remaining 14 cases had abnormal signal. There were 13 early warnings in SEP monitoring; 12 early warnings in MEP monitoring; 10 early warnings in EMG monitoring. There were 15 cases of early warning in the joint monitoring of the three, and the sensitivity of the combined monitoring of SEP + MEP + EMG was significantly higher than that of the single monitoring of SEP, MEP, and EMG (p < 0.05). There was no significant difference in specificity, positive predictive value, and negative predictive value between combined monitoring and single monitoring (p > 0.05). The combined monitoring of EMG, MEP, and SEP in orthopedic surgery can significantly improve the safety of surgery, its sensitivity and negative predictive value were significantly higher than the monitoring effects of the two alone.
format Online
Article
Text
id pubmed-9970720
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-99707202023-02-28 Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia Zhang, Mingmin Duan, Junfeng Chen, Yanchun Zhang, Chunyu Contrast Media Mol Imaging Research Article To study the application of intraoperative EMG intelligent monitoring in orthopedic surgery under general anesthesia, a total of 53 patients who underwent orthopedic surgery from February 2021 to February 2022 were selected. The combined monitoring of somatosensory evoked potential (SEP), motor evoked potential (MEP), and electromyography (EMG) was used to analyze the monitoring efficiency. In 38 of the 53 patients, the intraoperative signal was normal, and there was no postoperative neurological dysfunction; one case had abnormal signal, and the abnormality still existed after debugging, but no obvious neurological dysfunction was found after operation; the remaining 14 cases had abnormal signal. There were 13 early warnings in SEP monitoring; 12 early warnings in MEP monitoring; 10 early warnings in EMG monitoring. There were 15 cases of early warning in the joint monitoring of the three, and the sensitivity of the combined monitoring of SEP + MEP + EMG was significantly higher than that of the single monitoring of SEP, MEP, and EMG (p < 0.05). There was no significant difference in specificity, positive predictive value, and negative predictive value between combined monitoring and single monitoring (p > 0.05). The combined monitoring of EMG, MEP, and SEP in orthopedic surgery can significantly improve the safety of surgery, its sensitivity and negative predictive value were significantly higher than the monitoring effects of the two alone. Hindawi 2023-02-20 /pmc/articles/PMC9970720/ /pubmed/36860799 http://dx.doi.org/10.1155/2023/1484802 Text en Copyright © 2023 Mingmin Zhang et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhang, Mingmin
Duan, Junfeng
Chen, Yanchun
Zhang, Chunyu
Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia
title Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia
title_full Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia
title_fullStr Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia
title_full_unstemmed Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia
title_short Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia
title_sort application of intraoperative electromyography intelligent monitoring in orthopedic surgery under general anesthesia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970720/
https://www.ncbi.nlm.nih.gov/pubmed/36860799
http://dx.doi.org/10.1155/2023/1484802
work_keys_str_mv AT zhangmingmin applicationofintraoperativeelectromyographyintelligentmonitoringinorthopedicsurgeryundergeneralanesthesia
AT duanjunfeng applicationofintraoperativeelectromyographyintelligentmonitoringinorthopedicsurgeryundergeneralanesthesia
AT chenyanchun applicationofintraoperativeelectromyographyintelligentmonitoringinorthopedicsurgeryundergeneralanesthesia
AT zhangchunyu applicationofintraoperativeelectromyographyintelligentmonitoringinorthopedicsurgeryundergeneralanesthesia