Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia
To study the application of intraoperative EMG intelligent monitoring in orthopedic surgery under general anesthesia, a total of 53 patients who underwent orthopedic surgery from February 2021 to February 2022 were selected. The combined monitoring of somatosensory evoked potential (SEP), motor evok...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970720/ https://www.ncbi.nlm.nih.gov/pubmed/36860799 http://dx.doi.org/10.1155/2023/1484802 |
_version_ | 1784897960566325248 |
---|---|
author | Zhang, Mingmin Duan, Junfeng Chen, Yanchun Zhang, Chunyu |
author_facet | Zhang, Mingmin Duan, Junfeng Chen, Yanchun Zhang, Chunyu |
author_sort | Zhang, Mingmin |
collection | PubMed |
description | To study the application of intraoperative EMG intelligent monitoring in orthopedic surgery under general anesthesia, a total of 53 patients who underwent orthopedic surgery from February 2021 to February 2022 were selected. The combined monitoring of somatosensory evoked potential (SEP), motor evoked potential (MEP), and electromyography (EMG) was used to analyze the monitoring efficiency. In 38 of the 53 patients, the intraoperative signal was normal, and there was no postoperative neurological dysfunction; one case had abnormal signal, and the abnormality still existed after debugging, but no obvious neurological dysfunction was found after operation; the remaining 14 cases had abnormal signal. There were 13 early warnings in SEP monitoring; 12 early warnings in MEP monitoring; 10 early warnings in EMG monitoring. There were 15 cases of early warning in the joint monitoring of the three, and the sensitivity of the combined monitoring of SEP + MEP + EMG was significantly higher than that of the single monitoring of SEP, MEP, and EMG (p < 0.05). There was no significant difference in specificity, positive predictive value, and negative predictive value between combined monitoring and single monitoring (p > 0.05). The combined monitoring of EMG, MEP, and SEP in orthopedic surgery can significantly improve the safety of surgery, its sensitivity and negative predictive value were significantly higher than the monitoring effects of the two alone. |
format | Online Article Text |
id | pubmed-9970720 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-99707202023-02-28 Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia Zhang, Mingmin Duan, Junfeng Chen, Yanchun Zhang, Chunyu Contrast Media Mol Imaging Research Article To study the application of intraoperative EMG intelligent monitoring in orthopedic surgery under general anesthesia, a total of 53 patients who underwent orthopedic surgery from February 2021 to February 2022 were selected. The combined monitoring of somatosensory evoked potential (SEP), motor evoked potential (MEP), and electromyography (EMG) was used to analyze the monitoring efficiency. In 38 of the 53 patients, the intraoperative signal was normal, and there was no postoperative neurological dysfunction; one case had abnormal signal, and the abnormality still existed after debugging, but no obvious neurological dysfunction was found after operation; the remaining 14 cases had abnormal signal. There were 13 early warnings in SEP monitoring; 12 early warnings in MEP monitoring; 10 early warnings in EMG monitoring. There were 15 cases of early warning in the joint monitoring of the three, and the sensitivity of the combined monitoring of SEP + MEP + EMG was significantly higher than that of the single monitoring of SEP, MEP, and EMG (p < 0.05). There was no significant difference in specificity, positive predictive value, and negative predictive value between combined monitoring and single monitoring (p > 0.05). The combined monitoring of EMG, MEP, and SEP in orthopedic surgery can significantly improve the safety of surgery, its sensitivity and negative predictive value were significantly higher than the monitoring effects of the two alone. Hindawi 2023-02-20 /pmc/articles/PMC9970720/ /pubmed/36860799 http://dx.doi.org/10.1155/2023/1484802 Text en Copyright © 2023 Mingmin Zhang et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Mingmin Duan, Junfeng Chen, Yanchun Zhang, Chunyu Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia |
title | Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia |
title_full | Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia |
title_fullStr | Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia |
title_full_unstemmed | Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia |
title_short | Application of Intraoperative Electromyography Intelligent Monitoring in Orthopedic Surgery under General Anesthesia |
title_sort | application of intraoperative electromyography intelligent monitoring in orthopedic surgery under general anesthesia |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970720/ https://www.ncbi.nlm.nih.gov/pubmed/36860799 http://dx.doi.org/10.1155/2023/1484802 |
work_keys_str_mv | AT zhangmingmin applicationofintraoperativeelectromyographyintelligentmonitoringinorthopedicsurgeryundergeneralanesthesia AT duanjunfeng applicationofintraoperativeelectromyographyintelligentmonitoringinorthopedicsurgeryundergeneralanesthesia AT chenyanchun applicationofintraoperativeelectromyographyintelligentmonitoringinorthopedicsurgeryundergeneralanesthesia AT zhangchunyu applicationofintraoperativeelectromyographyintelligentmonitoringinorthopedicsurgeryundergeneralanesthesia |