Cargando…

Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles

PURPOSE: Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern...

Descripción completa

Detalles Bibliográficos
Autores principales: Najafiaghdam, Hossein, Pedroso, Cassio C. S., Torquato, Nicole A., Cohen, Bruce E., Anwar, Mekhail
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970948/
https://www.ncbi.nlm.nih.gov/pubmed/35312938
http://dx.doi.org/10.1007/s11307-022-01710-8
_version_ 1784898006349250560
author Najafiaghdam, Hossein
Pedroso, Cassio C. S.
Torquato, Nicole A.
Cohen, Bruce E.
Anwar, Mekhail
author_facet Najafiaghdam, Hossein
Pedroso, Cassio C. S.
Torquato, Nicole A.
Cohen, Bruce E.
Anwar, Mekhail
author_sort Najafiaghdam, Hossein
collection PubMed
description PURPOSE: Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. PROCEDURES: We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm [Formula: see text] 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. RESULTS: Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. CONCLUSION: The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11307-022-01710-8.
format Online
Article
Text
id pubmed-9970948
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-99709482023-03-01 Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles Najafiaghdam, Hossein Pedroso, Cassio C. S. Torquato, Nicole A. Cohen, Bruce E. Anwar, Mekhail Mol Imaging Biol Research Article PURPOSE: Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. PROCEDURES: We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm [Formula: see text] 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. RESULTS: Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. CONCLUSION: The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11307-022-01710-8. Springer International Publishing 2022-03-21 2023 /pmc/articles/PMC9970948/ /pubmed/35312938 http://dx.doi.org/10.1007/s11307-022-01710-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Najafiaghdam, Hossein
Pedroso, Cassio C. S.
Torquato, Nicole A.
Cohen, Bruce E.
Anwar, Mekhail
Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles
title Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles
title_full Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles
title_fullStr Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles
title_full_unstemmed Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles
title_short Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles
title_sort fully integrated ultra-thin intraoperative micro-imager for cancer detection using upconverting nanoparticles
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9970948/
https://www.ncbi.nlm.nih.gov/pubmed/35312938
http://dx.doi.org/10.1007/s11307-022-01710-8
work_keys_str_mv AT najafiaghdamhossein fullyintegratedultrathinintraoperativemicroimagerforcancerdetectionusingupconvertingnanoparticles
AT pedrosocassiocs fullyintegratedultrathinintraoperativemicroimagerforcancerdetectionusingupconvertingnanoparticles
AT torquatonicolea fullyintegratedultrathinintraoperativemicroimagerforcancerdetectionusingupconvertingnanoparticles
AT cohenbrucee fullyintegratedultrathinintraoperativemicroimagerforcancerdetectionusingupconvertingnanoparticles
AT anwarmekhail fullyintegratedultrathinintraoperativemicroimagerforcancerdetectionusingupconvertingnanoparticles