Cargando…
Compressive Strength of Temporary Crowns Made from Default design in Two Types of Software
STATEMENT OF THE PROBLEM: Various default values in each software can eventually lead to different crown thicknesses and affect their compressive strength. PURPOSE: This study aimed to compare the compressive strength of temporary crowns made with the milling machine, designed in Exocad and 3Shape D...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shiraz University of Medical Sciences
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9971611/ https://www.ncbi.nlm.nih.gov/pubmed/36864998 http://dx.doi.org/10.30476/DENTJODS.2022.89736.1433 |
_version_ | 1784898135103897600 |
---|---|
author | Ghaffari, Tahereh Nourizadeh, Amin Shafiei, Elnaz Mahboub, Farhang Kalantari, Amir Reza |
author_facet | Ghaffari, Tahereh Nourizadeh, Amin Shafiei, Elnaz Mahboub, Farhang Kalantari, Amir Reza |
author_sort | Ghaffari, Tahereh |
collection | PubMed |
description | STATEMENT OF THE PROBLEM: Various default values in each software can eventually lead to different crown thicknesses and affect their compressive strength. PURPOSE: This study aimed to compare the compressive strength of temporary crowns made with the milling machine, designed in Exocad and 3Shape Dental System software. MATERIALS AND METHOD: In this in vitro study, 90 temporary crowns were made and evaluated based on each software settings. For this purpose, a sound premolar was first scanned as a pre-operative model by 3Shape laboratory scanner. The standard tooth preparation and scanning were performed, and then the temporary crown files (designed by each software) were transferred to the Imesicore 350i milling machine. A total of 90 temporary crowns (45 based on the file of each software) were made using poly methyl methacrylate (PMMA) vita cad-temp block. The value of compressive force displayed on the monitor was recorded at the first crack and the ultimate failure of the crown. RESULTS: The first crack and the ultimate strength of crowns designed with the Exocad software was 903.5±96N and 1490±139.3N and for crowns designed with 3Shape Dental System software was 1060.4±160.2N and 1691.1±73.9N, respectively. The amount of compressive strength of temporary crowns made with 3Shape Dental System was significantly higher than those made with Exocad software and this difference was statistically significant(p= 0.000). CONCLUSION: The compressive strength of temporary dental crowns made by both softwares is in a clinically acceptable range, but considering that the average compressive strength in the 3Shape Dental System group was slightly higher than of the other group, it is preferable to design and fabricate with 3Shape Dental System software to increase the compressive strength of these crowns. |
format | Online Article Text |
id | pubmed-9971611 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Shiraz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-99716112023-03-01 Compressive Strength of Temporary Crowns Made from Default design in Two Types of Software Ghaffari, Tahereh Nourizadeh, Amin Shafiei, Elnaz Mahboub, Farhang Kalantari, Amir Reza J Dent (Shiraz) Original Article STATEMENT OF THE PROBLEM: Various default values in each software can eventually lead to different crown thicknesses and affect their compressive strength. PURPOSE: This study aimed to compare the compressive strength of temporary crowns made with the milling machine, designed in Exocad and 3Shape Dental System software. MATERIALS AND METHOD: In this in vitro study, 90 temporary crowns were made and evaluated based on each software settings. For this purpose, a sound premolar was first scanned as a pre-operative model by 3Shape laboratory scanner. The standard tooth preparation and scanning were performed, and then the temporary crown files (designed by each software) were transferred to the Imesicore 350i milling machine. A total of 90 temporary crowns (45 based on the file of each software) were made using poly methyl methacrylate (PMMA) vita cad-temp block. The value of compressive force displayed on the monitor was recorded at the first crack and the ultimate failure of the crown. RESULTS: The first crack and the ultimate strength of crowns designed with the Exocad software was 903.5±96N and 1490±139.3N and for crowns designed with 3Shape Dental System software was 1060.4±160.2N and 1691.1±73.9N, respectively. The amount of compressive strength of temporary crowns made with 3Shape Dental System was significantly higher than those made with Exocad software and this difference was statistically significant(p= 0.000). CONCLUSION: The compressive strength of temporary dental crowns made by both softwares is in a clinically acceptable range, but considering that the average compressive strength in the 3Shape Dental System group was slightly higher than of the other group, it is preferable to design and fabricate with 3Shape Dental System software to increase the compressive strength of these crowns. Shiraz University of Medical Sciences 2023-03 /pmc/articles/PMC9971611/ /pubmed/36864998 http://dx.doi.org/10.30476/DENTJODS.2022.89736.1433 Text en Copyright: © Journal of Dentistry https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License, ( http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ) which permits reusers to copy and redistribute the material in any medium or format if the original work is properly cited, and attribution is given to the creator. The license also permits for commercial use. |
spellingShingle | Original Article Ghaffari, Tahereh Nourizadeh, Amin Shafiei, Elnaz Mahboub, Farhang Kalantari, Amir Reza Compressive Strength of Temporary Crowns Made from Default design in Two Types of Software |
title | Compressive Strength of Temporary Crowns Made from Default design in Two Types of Software |
title_full | Compressive Strength of Temporary Crowns Made from Default design in Two Types of Software |
title_fullStr | Compressive Strength of Temporary Crowns Made from Default design in Two Types of Software |
title_full_unstemmed | Compressive Strength of Temporary Crowns Made from Default design in Two Types of Software |
title_short | Compressive Strength of Temporary Crowns Made from Default design in Two Types of Software |
title_sort | compressive strength of temporary crowns made from default design in two types of software |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9971611/ https://www.ncbi.nlm.nih.gov/pubmed/36864998 http://dx.doi.org/10.30476/DENTJODS.2022.89736.1433 |
work_keys_str_mv | AT ghaffaritahereh compressivestrengthoftemporarycrownsmadefromdefaultdesignintwotypesofsoftware AT nourizadehamin compressivestrengthoftemporarycrownsmadefromdefaultdesignintwotypesofsoftware AT shafieielnaz compressivestrengthoftemporarycrownsmadefromdefaultdesignintwotypesofsoftware AT mahboubfarhang compressivestrengthoftemporarycrownsmadefromdefaultdesignintwotypesofsoftware AT kalantariamirreza compressivestrengthoftemporarycrownsmadefromdefaultdesignintwotypesofsoftware |