Cargando…
Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study
BACKGROUND: The volume of remote monitoring (RM) data generates a significant workload and is generally dealt with by clinic staff during standard office hours, potentially delaying clinical action. OBJECTIVE: The purpose of this study was to determine the clinical efficiency and workflow of impleme...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975000/ https://www.ncbi.nlm.nih.gov/pubmed/36873319 http://dx.doi.org/10.1016/j.hroo.2022.11.002 |
_version_ | 1784898794862673920 |
---|---|
author | Heath, Kyle O’Shea, Catherine Thomas, Gijo Harper, Curtis Campbell, Kevin Sanders, Prashanthan Middeldorp, Melissa E. |
author_facet | Heath, Kyle O’Shea, Catherine Thomas, Gijo Harper, Curtis Campbell, Kevin Sanders, Prashanthan Middeldorp, Melissa E. |
author_sort | Heath, Kyle |
collection | PubMed |
description | BACKGROUND: The volume of remote monitoring (RM) data generates a significant workload and is generally dealt with by clinic staff during standard office hours, potentially delaying clinical action. OBJECTIVE: The purpose of this study was to determine the clinical efficiency and workflow of implementing intensive RM (IRM) in patients with cardiac implantable electronic device (CIED) when compared with standard RM (SRM). METHODS: From a cohort of >1500 remotely monitored devices, 70 patients were randomly selected to undergo IRM. For comparison, an equal number of matched patients were prospectively selected for SRM. Intensive follow-up occurred via automated vendor-neutral software with rapid alert processing by International Board of Heart Rhythm Examiners–certified device specialists. Standard follow-up was conducted by clinic staff during office hours via individual device vendor interfaces. Alerts were categorized on the basis of the level of acuity as actionable (red [high], yellow [moderate]), or green [not requiring action]). RESULTS: Over 9 months of follow-up, 922 remote transmissions were received; 339 (36.8%) were coded as actionable alerts (118 in IRM and 221 in SRM; P < .001). The median time from initial transmission to review was 6 hours (interquartile range [IQR] 1.8–16.8 hours) in the IRM group compared with 10.5 hours (IQR 6.0–32.2 hours) in the SRM group (P < .001). The median time from transmission to review of actionable alerts in the IRM group was 5.1 hours (IQR 2.3–8.9 hours) compared with 9.1 hours (IQR 6.7–32.5 hours) in the SRM group (P < .001). CONCLUSION: Intensive and managed RM results in a significant reduction in time to review alerts and number of actionable alerts. Monitoring with enhanced alert adjudication is needed to facilitate device clinic efficiency and optimize patient care. STUDY REGISTRATION: ACTRN12621001275853 |
format | Online Article Text |
id | pubmed-9975000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-99750002023-03-02 Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study Heath, Kyle O’Shea, Catherine Thomas, Gijo Harper, Curtis Campbell, Kevin Sanders, Prashanthan Middeldorp, Melissa E. Heart Rhythm O2 Clinical BACKGROUND: The volume of remote monitoring (RM) data generates a significant workload and is generally dealt with by clinic staff during standard office hours, potentially delaying clinical action. OBJECTIVE: The purpose of this study was to determine the clinical efficiency and workflow of implementing intensive RM (IRM) in patients with cardiac implantable electronic device (CIED) when compared with standard RM (SRM). METHODS: From a cohort of >1500 remotely monitored devices, 70 patients were randomly selected to undergo IRM. For comparison, an equal number of matched patients were prospectively selected for SRM. Intensive follow-up occurred via automated vendor-neutral software with rapid alert processing by International Board of Heart Rhythm Examiners–certified device specialists. Standard follow-up was conducted by clinic staff during office hours via individual device vendor interfaces. Alerts were categorized on the basis of the level of acuity as actionable (red [high], yellow [moderate]), or green [not requiring action]). RESULTS: Over 9 months of follow-up, 922 remote transmissions were received; 339 (36.8%) were coded as actionable alerts (118 in IRM and 221 in SRM; P < .001). The median time from initial transmission to review was 6 hours (interquartile range [IQR] 1.8–16.8 hours) in the IRM group compared with 10.5 hours (IQR 6.0–32.2 hours) in the SRM group (P < .001). The median time from transmission to review of actionable alerts in the IRM group was 5.1 hours (IQR 2.3–8.9 hours) compared with 9.1 hours (IQR 6.7–32.5 hours) in the SRM group (P < .001). CONCLUSION: Intensive and managed RM results in a significant reduction in time to review alerts and number of actionable alerts. Monitoring with enhanced alert adjudication is needed to facilitate device clinic efficiency and optimize patient care. STUDY REGISTRATION: ACTRN12621001275853 Elsevier 2022-11-17 /pmc/articles/PMC9975000/ /pubmed/36873319 http://dx.doi.org/10.1016/j.hroo.2022.11.002 Text en © 2022 Heart Rhythm Society. Published by Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Clinical Heath, Kyle O’Shea, Catherine Thomas, Gijo Harper, Curtis Campbell, Kevin Sanders, Prashanthan Middeldorp, Melissa E. Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study |
title | Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study |
title_full | Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study |
title_fullStr | Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study |
title_full_unstemmed | Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study |
title_short | Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study |
title_sort | impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: a pilot study |
topic | Clinical |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975000/ https://www.ncbi.nlm.nih.gov/pubmed/36873319 http://dx.doi.org/10.1016/j.hroo.2022.11.002 |
work_keys_str_mv | AT heathkyle impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy AT osheacatherine impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy AT thomasgijo impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy AT harpercurtis impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy AT campbellkevin impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy AT sandersprashanthan impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy AT middeldorpmelissae impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy |