Cargando…

Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study

BACKGROUND: The volume of remote monitoring (RM) data generates a significant workload and is generally dealt with by clinic staff during standard office hours, potentially delaying clinical action. OBJECTIVE: The purpose of this study was to determine the clinical efficiency and workflow of impleme...

Descripción completa

Detalles Bibliográficos
Autores principales: Heath, Kyle, O’Shea, Catherine, Thomas, Gijo, Harper, Curtis, Campbell, Kevin, Sanders, Prashanthan, Middeldorp, Melissa E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975000/
https://www.ncbi.nlm.nih.gov/pubmed/36873319
http://dx.doi.org/10.1016/j.hroo.2022.11.002
_version_ 1784898794862673920
author Heath, Kyle
O’Shea, Catherine
Thomas, Gijo
Harper, Curtis
Campbell, Kevin
Sanders, Prashanthan
Middeldorp, Melissa E.
author_facet Heath, Kyle
O’Shea, Catherine
Thomas, Gijo
Harper, Curtis
Campbell, Kevin
Sanders, Prashanthan
Middeldorp, Melissa E.
author_sort Heath, Kyle
collection PubMed
description BACKGROUND: The volume of remote monitoring (RM) data generates a significant workload and is generally dealt with by clinic staff during standard office hours, potentially delaying clinical action. OBJECTIVE: The purpose of this study was to determine the clinical efficiency and workflow of implementing intensive RM (IRM) in patients with cardiac implantable electronic device (CIED) when compared with standard RM (SRM). METHODS: From a cohort of >1500 remotely monitored devices, 70 patients were randomly selected to undergo IRM. For comparison, an equal number of matched patients were prospectively selected for SRM. Intensive follow-up occurred via automated vendor-neutral software with rapid alert processing by International Board of Heart Rhythm Examiners–certified device specialists. Standard follow-up was conducted by clinic staff during office hours via individual device vendor interfaces. Alerts were categorized on the basis of the level of acuity as actionable (red [high], yellow [moderate]), or green [not requiring action]). RESULTS: Over 9 months of follow-up, 922 remote transmissions were received; 339 (36.8%) were coded as actionable alerts (118 in IRM and 221 in SRM; P < .001). The median time from initial transmission to review was 6 hours (interquartile range [IQR] 1.8–16.8 hours) in the IRM group compared with 10.5 hours (IQR 6.0–32.2 hours) in the SRM group (P < .001). The median time from transmission to review of actionable alerts in the IRM group was 5.1 hours (IQR 2.3–8.9 hours) compared with 9.1 hours (IQR 6.7–32.5 hours) in the SRM group (P < .001). CONCLUSION: Intensive and managed RM results in a significant reduction in time to review alerts and number of actionable alerts. Monitoring with enhanced alert adjudication is needed to facilitate device clinic efficiency and optimize patient care. STUDY REGISTRATION: ACTRN12621001275853
format Online
Article
Text
id pubmed-9975000
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-99750002023-03-02 Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study Heath, Kyle O’Shea, Catherine Thomas, Gijo Harper, Curtis Campbell, Kevin Sanders, Prashanthan Middeldorp, Melissa E. Heart Rhythm O2 Clinical BACKGROUND: The volume of remote monitoring (RM) data generates a significant workload and is generally dealt with by clinic staff during standard office hours, potentially delaying clinical action. OBJECTIVE: The purpose of this study was to determine the clinical efficiency and workflow of implementing intensive RM (IRM) in patients with cardiac implantable electronic device (CIED) when compared with standard RM (SRM). METHODS: From a cohort of >1500 remotely monitored devices, 70 patients were randomly selected to undergo IRM. For comparison, an equal number of matched patients were prospectively selected for SRM. Intensive follow-up occurred via automated vendor-neutral software with rapid alert processing by International Board of Heart Rhythm Examiners–certified device specialists. Standard follow-up was conducted by clinic staff during office hours via individual device vendor interfaces. Alerts were categorized on the basis of the level of acuity as actionable (red [high], yellow [moderate]), or green [not requiring action]). RESULTS: Over 9 months of follow-up, 922 remote transmissions were received; 339 (36.8%) were coded as actionable alerts (118 in IRM and 221 in SRM; P < .001). The median time from initial transmission to review was 6 hours (interquartile range [IQR] 1.8–16.8 hours) in the IRM group compared with 10.5 hours (IQR 6.0–32.2 hours) in the SRM group (P < .001). The median time from transmission to review of actionable alerts in the IRM group was 5.1 hours (IQR 2.3–8.9 hours) compared with 9.1 hours (IQR 6.7–32.5 hours) in the SRM group (P < .001). CONCLUSION: Intensive and managed RM results in a significant reduction in time to review alerts and number of actionable alerts. Monitoring with enhanced alert adjudication is needed to facilitate device clinic efficiency and optimize patient care. STUDY REGISTRATION: ACTRN12621001275853 Elsevier 2022-11-17 /pmc/articles/PMC9975000/ /pubmed/36873319 http://dx.doi.org/10.1016/j.hroo.2022.11.002 Text en © 2022 Heart Rhythm Society. Published by Elsevier Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Clinical
Heath, Kyle
O’Shea, Catherine
Thomas, Gijo
Harper, Curtis
Campbell, Kevin
Sanders, Prashanthan
Middeldorp, Melissa E.
Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study
title Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study
title_full Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study
title_fullStr Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study
title_full_unstemmed Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study
title_short Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study
title_sort impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: a pilot study
topic Clinical
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975000/
https://www.ncbi.nlm.nih.gov/pubmed/36873319
http://dx.doi.org/10.1016/j.hroo.2022.11.002
work_keys_str_mv AT heathkyle impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy
AT osheacatherine impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy
AT thomasgijo impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy
AT harpercurtis impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy
AT campbellkevin impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy
AT sandersprashanthan impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy
AT middeldorpmelissae impactofintensivefollowupofcardiacimplantableelectronicdevicesviaremotemonitoringapilotstudy