Cargando…

Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study

OBJECTIVES: To three-dimensionally analyse the stress distribution and displacement pattern in the maxillofacial complex following intrusion and distalization of the maxillary arch using finite element analysis in skeletal class II malocclusion with prognathic maxilla and vertical maxillary excess u...

Descripción completa

Detalles Bibliográficos
Autores principales: Somaskandhan, Abinaya, Kumar, N M. Vijay, Vijayalakshmi, R. Devaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975133/
https://www.ncbi.nlm.nih.gov/pubmed/36854939
http://dx.doi.org/10.1186/s40510-023-00455-6
_version_ 1784898807633281024
author Somaskandhan, Abinaya
Kumar, N M. Vijay
Vijayalakshmi, R. Devaki
author_facet Somaskandhan, Abinaya
Kumar, N M. Vijay
Vijayalakshmi, R. Devaki
author_sort Somaskandhan, Abinaya
collection PubMed
description OBJECTIVES: To three-dimensionally analyse the stress distribution and displacement pattern in the maxillofacial complex following intrusion and distalization of the maxillary arch using finite element analysis in skeletal class II malocclusion with prognathic maxilla and vertical maxillary excess using miniplates and mini-implants. MATERIALS AND METHODS: Finite Element models of a skull, Y-shaped stainless steel miniplate, mini-implant and a posted arch were generated. Three force levels (1) 200 g (2) 300 g and (3) 500 g per side were applied to the assembly. The models were pre-processed and the analysis was performed using ANSYS version 18.1 software. Alterations in von mises stress, principal maximum stress, principal minimum stress and compressive stress were analysed around the sutures and surface landmarks. RESULTS: With miniplates, there was a maximum stress concentration at the zygomatic buttress with even stress distribution at the fronto-maxillary, zygomatico-temporal, zygomatico-frontal and pterygomaxillary sutures along with anatomical landmarks such as frontal process of maxilla, ANS, Point A, prosthion and maxillary process of zygoma. First molars experienced greater distalization effects with buccal flaring when miniplates were used. With mini-implants, canine and premolars also exhibited greater distalization effects. In the root apices, lateral incisors showed increased lingual root movement with mini-implants. CONCLUSION: Miniplates provide a greater distalizing effect while mini-implants produce increased intrusive effect. The distalizing effect is greater when 500 g of force is applied using miniplates with significantly even stress distribution and displacement pattern.
format Online
Article
Text
id pubmed-9975133
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-99751332023-03-02 Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study Somaskandhan, Abinaya Kumar, N M. Vijay Vijayalakshmi, R. Devaki Prog Orthod Research OBJECTIVES: To three-dimensionally analyse the stress distribution and displacement pattern in the maxillofacial complex following intrusion and distalization of the maxillary arch using finite element analysis in skeletal class II malocclusion with prognathic maxilla and vertical maxillary excess using miniplates and mini-implants. MATERIALS AND METHODS: Finite Element models of a skull, Y-shaped stainless steel miniplate, mini-implant and a posted arch were generated. Three force levels (1) 200 g (2) 300 g and (3) 500 g per side were applied to the assembly. The models were pre-processed and the analysis was performed using ANSYS version 18.1 software. Alterations in von mises stress, principal maximum stress, principal minimum stress and compressive stress were analysed around the sutures and surface landmarks. RESULTS: With miniplates, there was a maximum stress concentration at the zygomatic buttress with even stress distribution at the fronto-maxillary, zygomatico-temporal, zygomatico-frontal and pterygomaxillary sutures along with anatomical landmarks such as frontal process of maxilla, ANS, Point A, prosthion and maxillary process of zygoma. First molars experienced greater distalization effects with buccal flaring when miniplates were used. With mini-implants, canine and premolars also exhibited greater distalization effects. In the root apices, lateral incisors showed increased lingual root movement with mini-implants. CONCLUSION: Miniplates provide a greater distalizing effect while mini-implants produce increased intrusive effect. The distalizing effect is greater when 500 g of force is applied using miniplates with significantly even stress distribution and displacement pattern. Springer Berlin Heidelberg 2023-03-01 /pmc/articles/PMC9975133/ /pubmed/36854939 http://dx.doi.org/10.1186/s40510-023-00455-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Somaskandhan, Abinaya
Kumar, N M. Vijay
Vijayalakshmi, R. Devaki
Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study
title Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study
title_full Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study
title_fullStr Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study
title_full_unstemmed Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study
title_short Stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study
title_sort stress distribution and displacement in the maxillofacial complex during intrusion and distalization of the maxillary arch using miniplates versus mini-implants: a 3-dimensional finite element study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975133/
https://www.ncbi.nlm.nih.gov/pubmed/36854939
http://dx.doi.org/10.1186/s40510-023-00455-6
work_keys_str_mv AT somaskandhanabinaya stressdistributionanddisplacementinthemaxillofacialcomplexduringintrusionanddistalizationofthemaxillaryarchusingminiplatesversusminiimplantsa3dimensionalfiniteelementstudy
AT kumarnmvijay stressdistributionanddisplacementinthemaxillofacialcomplexduringintrusionanddistalizationofthemaxillaryarchusingminiplatesversusminiimplantsa3dimensionalfiniteelementstudy
AT vijayalakshmirdevaki stressdistributionanddisplacementinthemaxillofacialcomplexduringintrusionanddistalizationofthemaxillaryarchusingminiplatesversusminiimplantsa3dimensionalfiniteelementstudy