Cargando…
Occupational and patient doses for interventional radiology integrated into a dose management system
OBJECTIVES: The International Commission on Radiological Protection recommends managing patient and occupational doses as an integrated approach, for the optimisation of interventional procedures. The conventional passive personal dosimeters only allow one to know the accumulated occupational doses...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Institute of Radiology.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975364/ https://www.ncbi.nlm.nih.gov/pubmed/36533561 http://dx.doi.org/10.1259/bjr.20220607 |
_version_ | 1784898860283330560 |
---|---|
author | Vano, Eliseo Fernandez-Soto, José M Ten, José I Sanchez Casanueva, Roberto M |
author_facet | Vano, Eliseo Fernandez-Soto, José M Ten, José I Sanchez Casanueva, Roberto M |
author_sort | Vano, Eliseo |
collection | PubMed |
description | OBJECTIVES: The International Commission on Radiological Protection recommends managing patient and occupational doses as an integrated approach, for the optimisation of interventional procedures. The conventional passive personal dosimeters only allow one to know the accumulated occupational doses during a certain period of time. This information is not enough to identify if there is a lack of occupational radiation protection during some procedures. This paper describes the use of a dose management system (DMS) allowing patient and occupational doses for individual procedures to be audited. METHODS: The DMS manages patient and occupational doses measured by electronic personal dosimeters. One dosemeter located at the C-arm is used as a reference for scatter radiation. Data have been collected from five interventional rooms. Dosimetry data can be managed for the whole procedure and the different radiation events. Optimisation is done through auditing different sets of parameters for individual procedures: patient dose indicators, occupational dose values, the ratio between occupational doses, and the doses measured by the reference dosemeter at the C-arm, and the ratio between occupational and patient dose values. RESULTS: The managed data correspond to the year 2021, with around 4500 procedures, and 8000 records on occupational exposures. Patient and staff dose data (for 11 cardiologists, 7 radiologists and 8 nurses) were available for 3043 procedures. The DMS allows alerts for patient dose indicators and occupational exposures to be set. CONCLUSIONS: The main advantage of this integrated approach is the capacity to improve radiation safety for patients and workers together, auditing alerts for individual procedures. ADVANCES IN KNOWLEDGE: The management of patient and occupational doses together (measured with electronic personal dosimeters) for individual interventional procedures, using dose management systems, allows alerting optimisation on high-dose values for patients and staff. |
format | Online Article Text |
id | pubmed-9975364 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The British Institute of Radiology. |
record_format | MEDLINE/PubMed |
spelling | pubmed-99753642023-03-02 Occupational and patient doses for interventional radiology integrated into a dose management system Vano, Eliseo Fernandez-Soto, José M Ten, José I Sanchez Casanueva, Roberto M Br J Radiol Full Paper OBJECTIVES: The International Commission on Radiological Protection recommends managing patient and occupational doses as an integrated approach, for the optimisation of interventional procedures. The conventional passive personal dosimeters only allow one to know the accumulated occupational doses during a certain period of time. This information is not enough to identify if there is a lack of occupational radiation protection during some procedures. This paper describes the use of a dose management system (DMS) allowing patient and occupational doses for individual procedures to be audited. METHODS: The DMS manages patient and occupational doses measured by electronic personal dosimeters. One dosemeter located at the C-arm is used as a reference for scatter radiation. Data have been collected from five interventional rooms. Dosimetry data can be managed for the whole procedure and the different radiation events. Optimisation is done through auditing different sets of parameters for individual procedures: patient dose indicators, occupational dose values, the ratio between occupational doses, and the doses measured by the reference dosemeter at the C-arm, and the ratio between occupational and patient dose values. RESULTS: The managed data correspond to the year 2021, with around 4500 procedures, and 8000 records on occupational exposures. Patient and staff dose data (for 11 cardiologists, 7 radiologists and 8 nurses) were available for 3043 procedures. The DMS allows alerts for patient dose indicators and occupational exposures to be set. CONCLUSIONS: The main advantage of this integrated approach is the capacity to improve radiation safety for patients and workers together, auditing alerts for individual procedures. ADVANCES IN KNOWLEDGE: The management of patient and occupational doses together (measured with electronic personal dosimeters) for individual interventional procedures, using dose management systems, allows alerting optimisation on high-dose values for patients and staff. The British Institute of Radiology. 2023-02 2023-01-18 /pmc/articles/PMC9975364/ /pubmed/36533561 http://dx.doi.org/10.1259/bjr.20220607 Text en © 2022 The Authors. Published by the British Institute of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) , which permits unrestricted non-commercial reuse, provided the original author and source are credited. |
spellingShingle | Full Paper Vano, Eliseo Fernandez-Soto, José M Ten, José I Sanchez Casanueva, Roberto M Occupational and patient doses for interventional radiology integrated into a dose management system |
title | Occupational and patient doses for interventional radiology integrated into a dose management system |
title_full | Occupational and patient doses for interventional radiology integrated into a dose management system |
title_fullStr | Occupational and patient doses for interventional radiology integrated into a dose management system |
title_full_unstemmed | Occupational and patient doses for interventional radiology integrated into a dose management system |
title_short | Occupational and patient doses for interventional radiology integrated into a dose management system |
title_sort | occupational and patient doses for interventional radiology integrated into a dose management system |
topic | Full Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975364/ https://www.ncbi.nlm.nih.gov/pubmed/36533561 http://dx.doi.org/10.1259/bjr.20220607 |
work_keys_str_mv | AT vanoeliseo occupationalandpatientdosesforinterventionalradiologyintegratedintoadosemanagementsystem AT fernandezsotojosem occupationalandpatientdosesforinterventionalradiologyintegratedintoadosemanagementsystem AT tenjosei occupationalandpatientdosesforinterventionalradiologyintegratedintoadosemanagementsystem AT sanchezcasanuevarobertom occupationalandpatientdosesforinterventionalradiologyintegratedintoadosemanagementsystem |