Cargando…

Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research

The emerging disciplines of lipidomics and metabolomics show great potential for the discovery of diagnostic biomarkers, but appropriate pre-analytical sample-handling procedures are critical because several analytes are prone to ex vivo distortions during sample collection. To test how the intermed...

Descripción completa

Detalles Bibliográficos
Autores principales: Sens, A., Rischke, S., Hahnefeld, L., Dorochow, E., Schäfer, S.M.G., Thomas, D., Köhm, M., Geisslinger, G., Behrens, F., Gurke, R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975683/
https://www.ncbi.nlm.nih.gov/pubmed/36872954
http://dx.doi.org/10.1016/j.jmsacl.2023.02.002
_version_ 1784898926039531520
author Sens, A.
Rischke, S.
Hahnefeld, L.
Dorochow, E.
Schäfer, S.M.G.
Thomas, D.
Köhm, M.
Geisslinger, G.
Behrens, F.
Gurke, R.
author_facet Sens, A.
Rischke, S.
Hahnefeld, L.
Dorochow, E.
Schäfer, S.M.G.
Thomas, D.
Köhm, M.
Geisslinger, G.
Behrens, F.
Gurke, R.
author_sort Sens, A.
collection PubMed
description The emerging disciplines of lipidomics and metabolomics show great potential for the discovery of diagnostic biomarkers, but appropriate pre-analytical sample-handling procedures are critical because several analytes are prone to ex vivo distortions during sample collection. To test how the intermediate storage temperature and storage period of plasma samples from K3EDTA whole-blood collection tubes affect analyte concentrations, we assessed samples from non-fasting healthy volunteers (n = 9) for a broad spectrum of metabolites, including lipids and lipid mediators, using a well-established LC-MS-based platform. We used a fold change-based approach as a relative measure of analyte stability to evaluate 489 analytes, employing a combination of targeted LC-MS/MS and LC-HRMS screening. The concentrations of many analytes were found to be reliable, often justifying less strict sample handling; however, certain analytes were unstable, supporting the need for meticulous processing. We make four data-driven recommendations for sample-handling protocols with varying degrees of stringency, based on the maximum number of analytes and the feasibility of routine clinical implementation. These protocols also enable the simple evaluation of biomarker candidates based on their analyte-specific vulnerability to ex vivo distortions. In summary, pre-analytical sample handling has a major effect on the suitability of certain metabolites as biomarkers, including several lipids and lipid mediators. Our sample-handling recommendations will increase the reliability and quality of samples when such metabolites are necessary for routine clinical diagnosis.
format Online
Article
Text
id pubmed-9975683
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-99756832023-03-02 Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research Sens, A. Rischke, S. Hahnefeld, L. Dorochow, E. Schäfer, S.M.G. Thomas, D. Köhm, M. Geisslinger, G. Behrens, F. Gurke, R. J Mass Spectrom Adv Clin Lab Articles from the special issue on Biospecimen Pre-Analytics: Identifying and Controlling Ex Vivo Distortion of In Vivo Reality Edited by Chad Borges, Anne Bendt, Robert Gurke and Julijana Ivanisevic The emerging disciplines of lipidomics and metabolomics show great potential for the discovery of diagnostic biomarkers, but appropriate pre-analytical sample-handling procedures are critical because several analytes are prone to ex vivo distortions during sample collection. To test how the intermediate storage temperature and storage period of plasma samples from K3EDTA whole-blood collection tubes affect analyte concentrations, we assessed samples from non-fasting healthy volunteers (n = 9) for a broad spectrum of metabolites, including lipids and lipid mediators, using a well-established LC-MS-based platform. We used a fold change-based approach as a relative measure of analyte stability to evaluate 489 analytes, employing a combination of targeted LC-MS/MS and LC-HRMS screening. The concentrations of many analytes were found to be reliable, often justifying less strict sample handling; however, certain analytes were unstable, supporting the need for meticulous processing. We make four data-driven recommendations for sample-handling protocols with varying degrees of stringency, based on the maximum number of analytes and the feasibility of routine clinical implementation. These protocols also enable the simple evaluation of biomarker candidates based on their analyte-specific vulnerability to ex vivo distortions. In summary, pre-analytical sample handling has a major effect on the suitability of certain metabolites as biomarkers, including several lipids and lipid mediators. Our sample-handling recommendations will increase the reliability and quality of samples when such metabolites are necessary for routine clinical diagnosis. Elsevier 2023-02-17 /pmc/articles/PMC9975683/ /pubmed/36872954 http://dx.doi.org/10.1016/j.jmsacl.2023.02.002 Text en © 2023 THE AUTHORS https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Articles from the special issue on Biospecimen Pre-Analytics: Identifying and Controlling Ex Vivo Distortion of In Vivo Reality Edited by Chad Borges, Anne Bendt, Robert Gurke and Julijana Ivanisevic
Sens, A.
Rischke, S.
Hahnefeld, L.
Dorochow, E.
Schäfer, S.M.G.
Thomas, D.
Köhm, M.
Geisslinger, G.
Behrens, F.
Gurke, R.
Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research
title Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research
title_full Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research
title_fullStr Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research
title_full_unstemmed Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research
title_short Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research
title_sort pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in lc-ms-based clinical research
topic Articles from the special issue on Biospecimen Pre-Analytics: Identifying and Controlling Ex Vivo Distortion of In Vivo Reality Edited by Chad Borges, Anne Bendt, Robert Gurke and Julijana Ivanisevic
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9975683/
https://www.ncbi.nlm.nih.gov/pubmed/36872954
http://dx.doi.org/10.1016/j.jmsacl.2023.02.002
work_keys_str_mv AT sensa preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT rischkes preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT hahnefeldl preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT dorochowe preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT schafersmg preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT thomasd preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT kohmm preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT geisslingerg preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT behrensf preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch
AT gurker preanalyticalsamplehandlingstandardizationforreliablemeasurementofmetabolitesandlipidsinlcmsbasedclinicalresearch