Cargando…
A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism
BACKGROUND: To compare the safety, effectiveness, electrophysiological characteristics, and mechanisms of different approaches for the ablation of para-Hisian accessory pathways (APs). METHOD: Eighteen consecutive patients with para-Hisian APs were enrolled in this study. Detailed mapping of retrogr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9977842/ https://www.ncbi.nlm.nih.gov/pubmed/35974118 http://dx.doi.org/10.1007/s10840-022-01343-5 |
_version_ | 1784899383425236992 |
---|---|
author | Pang, Yang Chen, Qingxing Xu, Ye Cheng, Kuan Ling, Yunlong Ge, Junbo Zhu, Wenqing |
author_facet | Pang, Yang Chen, Qingxing Xu, Ye Cheng, Kuan Ling, Yunlong Ge, Junbo Zhu, Wenqing |
author_sort | Pang, Yang |
collection | PubMed |
description | BACKGROUND: To compare the safety, effectiveness, electrophysiological characteristics, and mechanisms of different approaches for the ablation of para-Hisian accessory pathways (APs). METHOD: Eighteen consecutive patients with para-Hisian APs were enrolled in this study. Detailed mapping of retrograde conduction as well as antegrade conduction (if possible) in both the right sided His bundle region and non-coronary cusp (NCC) region was performed before ablation. Ten patients underwent initial ablation in the right septal (RS) region while the remaining 8 patients were ablated in NCC region. Repeat ablation was attempted in an alternative region if ablation at the first site failed. RESULTS: Among the patients whose procedures were successful, 7 cases were successfully ablated with a NCC approach while 10 were conventionally ablated in RS region. For successful procedures targeting the NCC region, the earliest atrial activation (EAA) in NCC region preceded that at RS region by 4–13 ms. The distance between NCC targets and near-field His potential (NFH) points was longer than that between RS targets and NFH points. Additionally, the risk of complication after ablation in NCC region was lower compared with that following RS-targeted procedure. CONCLUSION: NCC approach provided a high success rate and low risk of complication for the ablation of para-Hisian APs as long as EAA was observed in NCC region. Sites of successful para-Hisian AP ablation in NCC region had different retrograde mapping patterns in comparison with successful ablation sites in the RS region. |
format | Online Article Text |
id | pubmed-9977842 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-99778422023-03-03 A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism Pang, Yang Chen, Qingxing Xu, Ye Cheng, Kuan Ling, Yunlong Ge, Junbo Zhu, Wenqing J Interv Card Electrophysiol Article BACKGROUND: To compare the safety, effectiveness, electrophysiological characteristics, and mechanisms of different approaches for the ablation of para-Hisian accessory pathways (APs). METHOD: Eighteen consecutive patients with para-Hisian APs were enrolled in this study. Detailed mapping of retrograde conduction as well as antegrade conduction (if possible) in both the right sided His bundle region and non-coronary cusp (NCC) region was performed before ablation. Ten patients underwent initial ablation in the right septal (RS) region while the remaining 8 patients were ablated in NCC region. Repeat ablation was attempted in an alternative region if ablation at the first site failed. RESULTS: Among the patients whose procedures were successful, 7 cases were successfully ablated with a NCC approach while 10 were conventionally ablated in RS region. For successful procedures targeting the NCC region, the earliest atrial activation (EAA) in NCC region preceded that at RS region by 4–13 ms. The distance between NCC targets and near-field His potential (NFH) points was longer than that between RS targets and NFH points. Additionally, the risk of complication after ablation in NCC region was lower compared with that following RS-targeted procedure. CONCLUSION: NCC approach provided a high success rate and low risk of complication for the ablation of para-Hisian APs as long as EAA was observed in NCC region. Sites of successful para-Hisian AP ablation in NCC region had different retrograde mapping patterns in comparison with successful ablation sites in the RS region. Springer US 2022-08-16 2023 /pmc/articles/PMC9977842/ /pubmed/35974118 http://dx.doi.org/10.1007/s10840-022-01343-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Pang, Yang Chen, Qingxing Xu, Ye Cheng, Kuan Ling, Yunlong Ge, Junbo Zhu, Wenqing A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism |
title | A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism |
title_full | A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism |
title_fullStr | A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism |
title_full_unstemmed | A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism |
title_short | A new insight into the different approaches for the ablation of para-Hisian accessory pathways: safety, effectiveness, and mechanism |
title_sort | new insight into the different approaches for the ablation of para-hisian accessory pathways: safety, effectiveness, and mechanism |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9977842/ https://www.ncbi.nlm.nih.gov/pubmed/35974118 http://dx.doi.org/10.1007/s10840-022-01343-5 |
work_keys_str_mv | AT pangyang anewinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT chenqingxing anewinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT xuye anewinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT chengkuan anewinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT lingyunlong anewinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT gejunbo anewinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT zhuwenqing anewinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT pangyang newinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT chenqingxing newinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT xuye newinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT chengkuan newinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT lingyunlong newinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT gejunbo newinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism AT zhuwenqing newinsightintothedifferentapproachesfortheablationofparahisianaccessorypathwayssafetyeffectivenessandmechanism |